Evaluation of the lift-off robustness of eddy current imaging techniques
Source abstract
Abstract
Abstract The development of lift-off invariant strategies is one of the main goals in Eddy Current Non-Destructive Testing research. In the present work, from the analysis of amplitude and phase signals of magnetic field sensors under Multi-Frequency Eddy Current excitation, two imaging procedures are analyzed and compared with respect to their ability to retrieve reliable results even in presence of huge changes of lift-off. A figure of merit based on the Signal to Noise Ratio evaluated on the 2D reconstructed images allows the comparison of the different strategies in terms of the quality of the image to show the defect. The numerical and the experimental tests realized show that the imaging procedure relying on the analysis of the phase-lag is quite insensitive to changes in the lift-off with respect to that based on the amplitude analysis. In detail the former guarantees good results even when the probe lift-off is randomly changed during the test with variations up to 3 mm, while the latter is able to tolerate only lift-off fluctuation lower than 1 mm.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Welding Techniques and Residual Stresses · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Numerical and experimental study of eddy current probes in NDT of structures with deep flaws10.1016/0963-8695(94)00010-H ↗
2. Pulsed eddy current signal analysis: application to the experimental detection and characterization of deep flaws in highly conductive materials10.1016/S0963-8695(96)00072-2 ↗
3. Crack detection and recognition using an eddy current differential probe10.1109/20.767393 ↗
4. Design of a pulsed eddy current sensor for detection of defects in aircraft lap-joints10.1016/S0924-4247(02)00195-4 ↗
5. Non-destructive techniques based on eddy current testing10.3390/s110302525 ↗
6. Non-destructive characterisation of carbon-fibre-reinforced plastics by means of eddy-currents10.1016/S0266-3538(00)00164-0 ↗
7. Noncontact characterization of carbon-fiber-reinforced plastics using multifrequency eddy current sensors10.1109/TIM.2008.2005072 ↗
8. Hoshikawa H, Koyama K, A new eddy current surface probe without lift-off noise. In: Proceedings of the 10th APCNDT; 2001, p. 275–8575.10.1016/B978-008043799-6/50016-1 ↗
9. Yin W, Xu K, A novel triple-coil electromagnetic sensor for thickness measurement immune to lift-off variations. In: IEEE transactions on instrumentation and measurement, 65 (1), p. 164–69.10.1109/TIM.2015.2479106 ↗
10. Development of differential probes in pulsed eddy current testing for noise suppression10.1016/j.sna.2006.10.013 ↗
11. Signal characteristics of differential-pulsed eddy current sensors in the evaluation of plate thickness10.1016/j.ndteint.2008.09.006 ↗
12. Reduction of lift-off effects for pulsed eddy current NDT10.1016/j.ndteint.2004.09.007 ↗
13. Analysis of the liftoff effect of phase spectra for eddy current sensors10.1109/TIM.2007.908273 ↗
14. Study of lift-off invariance for pulsed eddy-current signals10.1109/TMAG.2008.2006246 ↗
15. Liftoff insensitive thickness measurement of aluminum plates using harmonic eddy current excitation and a GMR sensor10.1016/j.measurement.2012.04.025 ↗
16. Multi-frequency ECT with AMR sensor10.1016/j.ndteint.2011.04.004 ↗
17. Multifrequency excitation and support vector machine regressor for ECT defect characterization10.1109/TIM.2013.2292326 ↗
18. An experimental comparison of multi-frequency and chirp excitations for eddy current testing on thin defects
19. Characterization of subsurface defects in aeronautical riveted lap-joints using multi-frequency eddy current imaging10.1016/j.ndteint.2008.10.005 ↗
20. Pulsed eddy-current based giant magnetoresistive system for the inspection of aircraft structures10.1109/TMAG.2009.2032330 ↗
21. Udpa · 1985 · 499
22. Eddy-current probe impedance due to a volumetric flaw10.1063/1.349615 ↗
23. Fast flaw reconstruction from 3D eddy current data10.1109/20.717657 ↗
24. Diffusion of current into conductors
25. Defect detection and classification using a SQUID based multiple frequency eddy current NDE system10.1109/77.919525 ↗
26. Sikora R., Chady T, Gratkowski S, Komorowski M, and Stawicki K., Eddy current testing of thick aluminum plates with hidden cracks. In: AIP Conference Proceedings A, p. 427–34; 2003.10.1063/1.1570167 ↗
27. Ricci M, Silipigni G, Ferrigno L, Laracca M, Adewale ID, Tian GY., Analysis of the influence of lift-off variation on Eddy-Current images, In: Proceedings of IEEE Metrology for Aerospace (MetroAeroSpace), 4-5 June, Benevento, Italy, pp. 182–87; 2015.10.1109/MetroAeroSpace.2015.7180650 ↗
28. Study on the transformer equivalent circuit of eddy current nondestructive evaluation10.1016/S0963-8695(03)00003-3 ↗
29. Lift-off and tilt effects on eddy current sensor measurements: a 3-D finite element study10.1051/epjap:2001002 ↗
30. Zhang Y-H, Luo F-L, Sun H-X. Impedance evaluation of a probe-coil's lift-off and tilt effect in eddy-current nondestructive inspection by 3D finite element modeling. In: Proceedings of the 17th world conference on nondestructive testing; 2008.
31. Synthesis of low-peak-factor signals and binary sequences with low autocorrelation10.1109/TIT.1970.1054411 ↗
32. Exploiting pseudorandom sequences to enhance noise immunity for air-coupled ultrasonic nondestructive testing10.1109/TIM.2012.2200409 ↗
33. GMR array uniform eddy current probe for defect detection in conductive specimens10.1016/j.measurement.2013.06.050 ↗
34. Study of pulse eddy current probes detecting cracks extending in all directions10.1016/j.sna.2007.07.008 ↗
35. Rotating field EC-GMR sensor for crack detection at fastener site in layered structures10.1109/JSEN.2014.2341653 ↗