journal article·2013-12

Electromagnetic characterization of grouting materials of bridge post tensioned ducts for NDT using capacitive probe

T. Bore, D. Placko, F. Taillade, P. Sabouroux

Publisher page

Abstract

The use of a capacitive probe as a non-destructive investigative technique for controlling the post tensioned ducts of bridges has gained increasing acceptance in France since several years. A field campaign measurement made in 2006 has shown the performance of the capacitive probe developed by the IFSTTAR. Nevertheless, some results are not understood, and in particular the behaviour of the probe when cement exudation product are present in the duct. Without an accurate knowledge of the electromagnetic properties of those products it is impossible to quantitatively assess the results of our capacitive probe. This paper reports the development of a coaxial transmission line feature. It was designed to allow the evaluation of a large type of material (liquid, paste or granular) over a large frequency range (50 MHz-4 GHz at maximum). A calibration scheme developed before at the Fresnel Institute was used. Using a two port S parameter instrument, the complex permittivity and magnetic permeability were evaluated by frequency domain measurement. The electromagnetic characterization of cement paste, cement exudation products and injection wax has brought us some key results in the interpretation of the capacitive probe signal. The results of this characterization were then used in a 3D semi analytical modelling of the problem. The studies of configurations with exudation products are presented and compared to experimental results obtained with our capacitive probe on laboratory duct.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Microwave and Dielectric Measurement Techniques · Geophysical Methods and Applications · Electromagnetic Compatibility and Measurements

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (47)

Show source-provided references
1. Le Roy R. Rhéologie et stabilité des matrices cimentaires et des coulis. Etudes et recherches des Laboratoires des ponts et chaussées, LCPC Paris; 2006.
2. Electrochemical behaviour and corrosion sensitivity of prestressed steel in cement grout10.2495/ECOR070261 ↗
3. Determination of the repair grout volume to fill voids in external post-tensioned tendons10.12989/sem.2012.42.1.025 ↗
4. Comparison of NDT techniques on a post-tensioned beam before its autopsy10.1016/S0963-8695(02)00027-0 ↗
5. Non-destructive testing methods to identify voids in external post-tensioned tendons10.1007/s12205-012-1295-0 ↗
6. Mesure de la teneur en eau des sols et des matériaux par une méthode capacitive: 3—applications de la méthode capacitive de mesure de la teneur en eau
7. Use of capacitance and GPR techniques for the non-destructive evaluation of cover concrete10.1016/j.ndteint.2007.06.004 ↗
8. Coplanar capacitance sensors for detecting water intrusion in composite structure
9. Measurement and applications of dielectric properties of agricultural products10.1109/19.126644 ↗
10. Characterization of heterogeneous system by dielectric spectroscopy10.1016/S0079-6700(02)00015-1 ↗
11. Dupas A, Sudret JP, Chabert A. Méthode de diagnostic de câbles de précontrainte externe contenu dans des gaines. French patent no. 0107719, Institut National de la Propriété Industrielle, Paris.
12. Taillade F, Aubagnac C, Cottineau L-M. Capacitive probe for non destructive inspection of external post-tensioned ducts, 35th annual review of progress in quantitative nondestructive evaluation, Chicago, USA, July; 2008.10.1063/1.3114136 ↗
13. A resonant cavity for high-accuracy measurement of micro-wave dielectric properties10.1088/0957-0233/7/9/010 ↗
14. Near field scanning microwave probe based on a dielectric resonator10.1063/1.1351837 ↗
15. Measurement of the intrinsic materials by time domain techniques
16. Automatic measurement of complex dielectric constant and permeability at microwave frequencies
17. A new tool for accurate S-parameters and permittivity reconstruction
18. Improved technique for determining complex permittivity with the transmission/reflection method10.1109/22.57336 ↗
19. Synthesis of all known analytical permittivity reconstruction techniques of nonmagnetic materials from reflection and transmission measurements10.1109/LGRS.2005.853199 ↗
20. Pozar D. Microwave engineering. Wiley; 1998 54-5.
21. Agilent—application note no.1364-1: de-embedding and embedding S-parameter network using a vector network analyzer.
22. Sabouroux P, et Boschi P. Simplification de la procédure de mesure de caractéristiques électromagnétiques de matériaux en temps réel., Revue de l’Electricité et de l’Electronique (REE)—no. 8; November 2005. p 84–9.10.3845/ree.2005.059 ↗
23. Sabouroux P, et Boschi P. EpsiMu: un nouvel outil pour déterminer les caractéristiques électromagnétiques de matériaux dans le domaine des hyperfréquences, Revue de l’Electricité et de l’Electronique (REE)—no. 10; 2005. p. 58–62.10.3845/ree.2005.076 ↗
24. EpsiMu a tool for permittivity and permeability measurement in microwave domain at real time of all materials. application to solid and semi-solid materials10.1002/mop.25570 ↗
25. Bore T. Amélioration du diagnostic de l’endommagement des gaines de précontraintes extérieures par sonde capacitive. Phd thesis. Conservatoire National des Arts et Métiers, Paris; 2011.
26. Ba D. Optimisation d’une procédure de caractérisation électromagnétique de matériaux dans le domaine des micro-ondes. Application aux milieux granulaires secs et humides. Phd thesis. Université de Provence; 2010.
27. Bore T, Placko D, Coelho D, Delepine-Lesoille S, Gatabin C, Sabouroux P, et al. Design and evaluation of two coaxial transmission lines to characterize electromagnetic properties of hard clays (non crushed) and concrete. In: Proceedings of the advanced electromagnetics symposium, AES; 2012. p. 546–55.
28. Wagner N, Bore T, Robinet JC, Coelho D, Taillade F, Delepine-Lesoille S. Dielectric relaxation of Callovo-Oxfordian clay-rock. Journal of Geophysical Research, In Press.
29. Robert A. Recherche de méthodes d’interprétation des mesures géoradar et de thermographie infrarouge appliquées au contrôle non destructif et à l’auscultation in situ des matériaux de construction. Phd thesis. EPFL, Lausanne; 1997.
30. Coaxial/cylindrical transition line for broadband permittivity measurement of civil engineering materials10.1088/0957-0233/17/8/026 ↗
31. Design and evaluation of a coaxial transmission line fixture to characterize Portland cement concrete10.1016/S0950-0618(97)00034-2 ↗
32. Characterization of Portland cement concrete using electromagnetic waves over the microwave frequencies10.1016/S0008-8846(98)00076-3 ↗
33. Bungey JH, Shaw MR, Millard SG, Soutsos MN, Austin BA. The influence of concrete composition upon radar test results. In: Proceeding of the NDT-CE, NDT in civil engineering conference; 1997.
34. Dielectric properties of concrete and their influence on radar testing10.1016/S0963-8695(01)00009-3 ↗
35. Coaxial transmission line: development of test procedure for concrete10.1061/(ASCE)0899-1561(2001)13:3(202) ↗
36. Dielectric permittivity of concrete between 50MHz and 1GHz and GPR measurement for building materials evaluation10.1016/S0926-9851(98)00009-3 ↗
37. Design and calibration of a large broadband dielectric measurement cell10.1109/36.103291 ↗
38. Impedance spectroscopy study of hardened Portland cement paste10.1016/S0008-8846(02)00720-2 ↗
39. Effect of admixtures on the dielectric constant of cement paste10.1016/S0008-8846(01)00475-6 ↗
40. Cure state monitoring and water to cement ratio to determination of fresh Portland cement based materials using near field microwave techniques10.1109/19.744313 ↗
41. Non destructive testing of hardened cement specimens at microwave frequencies using a simple free space method10.1016/j.ndteint.2009.04.004 ↗
42. Blactot E. Etude de paramètres de durabilité des aciers de précontrainte dans les coulis de ciment ségrégés. PhD thesis. Université Pierre et Marie Curie, Paris; 2008.
43. Placko · 2007
44. Distribured point source method for modeling and imaging in electrostatic and electromagnetic problems
45. Bore T, Taillade F, Placko D, Himbert M. Capacitive probe for non destructive inspection of external post-tensioned ducts: modeling by DPSM technique, 36th annual review of progress in quantitavive nondestructive evaluation, University of Rhodes Island, USA; July 2009.10.1063/1.3362353 ↗
46. Capacitive sensor for measuring the filled of post-tensioned ducts. Experimental set-up, modelling and signal processing10.1109/JSEN.2012.2219392 ↗
47. Kretz T, Lacombe JM, Godart B. Information note to raise awareness of existing structures with external prestressing protected by cement grout in contact with the tensile elements. Information note of the Sétra—civil engineering structures no. 29 , 2008.