A practical method to calibrate the slant angle of central X-ray for laminography scanning system
Source abstract
Abstract
Computed laminography (CL) has a particular function in plate-type structure tomography. For CL reconstruction, slant angle of the central X-ray is an important parameter and must be calibrated accurately. A practical feasible calibration method to determine the slant angle is proposed. According to this method, a spherical phantom is fixed on the rotary table and turns a full 360 rotation. Then, image processing and the least-square fitting are performed to figure out the locus of the projection. Consequently, the slant angle is achieved in accordance with the property of the fitted ellipse. The experimental results prove that this method is easy to implement and meet the inspection requirements. (C) 2014 Elsevier Ltd. All rights reserved.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging · Advanced X-ray Imaging Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. Cone-beam digital tomosynthesis for thin slab objects10.1016/j.ndteint.2012.01.008 ↗
2. Cone-beam CT reconstruction for planar object10.1016/j.ndteint.2011.08.010 ↗
3. Three-dimensional X-ray laminography as a tool for detection and characterization of BGA package defects10.1109/TCAPT.2002.1010010 ↗
4. X-ray laminographic application of lens-coupled CMOS detector for PCB inspection
5. Three-dimensional image reconstruction by digital tomosynthesis using inverse filtering10.1109/42.232260 ↗
6. Tomosynthesis imaging of the chest10.1097/RTI.0b013e318173e162 ↗
7. X-ray computed laminography: an approach of computed tomography for applications with limited access10.1016/S0029-5493(98)00319-7 ↗
8. Baranov V, Ewert U. Industrial application of digital tomosynthesis and special types of non-linear backprojection algorithms. In: Proceedings of international symposium: computer method and inverse problems in non-destructive testing and diagnostics (CM NDT-95). Minsk; 1995. p. 82–6.
9. New reconstruction method for X-ray testing of multilayer printed circuit board10.1117/1.3430629 ↗
10. An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms10.1088/0031-9155/53/14/009 ↗
11. Direct determination of geometric alignment parameters for cone-beam scanners10.1088/0031-9155/54/6/016 ↗
12. Geometric misalignment and calibration in cone-beam tomography10.1118/1.1803792 ↗
13. Estimation of geometrical parameters and collimator evaluation for cone beam tomography10.1118/1.596505 ↗
14. Characterization of pinhole SPECT acquisition geometry10.1109/TMI.2003.812258 ↗
15. Calibration method of projection coordinate system for X-ray cone-beam laminography scanning system10.1016/j.ndteint.2012.08.005 ↗
16. A calibration method for misaligned scanner geometry in cone-beam computed tomography10.1016/j.ndteint.2006.03.002 ↗
17. A new method to determine the center of rotation shift in 2D-ICT scanning system using image cross correlation10.1016/j.ndteint.2011.09.001 ↗
18. Three-dimensional quantitative in situ study of crack initiation and propagation in AA6061 aluminum alloy sheets via synchrotron laminography and finite-element simulations10.1016/j.actamat.2013.01.035 ↗
19. Neutron laminography—a novel approach to three-dimensional imaging of flat objects with neutrons10.1016/j.nima.2011.01.114 ↗
20. Image quality assessment: from error visibility to structural similarity10.1109/TIP.2003.819861 ↗
21. Image reconstruction with a shift-variant filtration in circular cone-beam CT10.1002/ima.20026 ↗
22. Imaging and measuring methods for coating layer thickness of TRISO-coated fuel particles with high accuracy10.1016/j.ndteint.2013.01.016 ↗
23. Automatic weld defect detection based on potential defect tracking in real-time radiographic image sequence10.1016/j.ndteint.2011.10.008 ↗
24. Automatic multilevel thresholding based two-stage OSTU׳s method with cluster determination by valley estimation
25. Optimal ellipse fitting method based on least-square principle
26. A new method to determine the projected coordinate origin of cone-beam CT system using elliptical projection10.1088/1674-1137/34/10/022 ↗