journal article·2024-10Open access

Pulse compression with and without matched filtering: Why codes beat chirps

Connor Challinor, Frederic Cegla

Abstract

Pulse compression based excitation signals have been shown to improve signal quality in many active ranging applications without negatively impacting range resolution. Most prior work into using pulse compression presents the technique as if matched filtering is necessary to successfully achieve signal compression. Matched filtering against modulated excitation signals does result in useful information compression, however, it also suppresses information outside of the bandwidth of the transmission signal. This can distort or remove useful information in some applications, such as ultrasonic guided wave inspections, making the processing step unsuitable. In this paper, we show that when pulse compression with coded excitation is employed, a second filtering option is available for compressing the modulated information. The second option, which we have termed the sequence filter, utilises sequence elements as the template against which the filtering of coded excitation measurements is undertaken, thereby allowing compression to be achieved independent of received signal frequency content. We verify that sequence filtering successfully produces signal compression in two experimental ultrasound non-destructive testing applications where frequency modulated pulse compression was unsuitable. With both sequence filtering and matched filtering, we show signal-to-noise ratio gains in excess of 20 dB from using pulse compression.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Flow Measurement and Analysis · Ultrasound Imaging and Elastography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Coded waveforms for optimised air-coupled ultrasonic nondestructive evaluation10.1016/j.ultras.2014.03.007 ↗
2. Simultaneous excitation system for efficient guided wave structural health monitoring10.1016/j.ymssp.2017.03.036 ↗
3. Advanced orthogonal frequency and phase modulated waveform for ultrasonic phased array tfm detection in cfrp composites
4. Ultrasonic imaging of thick carbon fiber reinforced polymers through pulse-compression-based phased array10.3390/app11041508 ↗
5. A signal processing approach to exploit chirp excitation in lamb wave defect detection and localization procedures10.1016/j.ymssp.2012.10.018 ↗
6. Excitation waveform design for lamb wave pulse compression10.1109/TUFFC.2015.2496292 ↗
7. Pulse-compression ultrasonic technique for the inspection of forged steel with high attenuation10.1784/insi.2012.54.2.91 ↗
8. Simultaneous coded plane-wave imaging using an advanced ultrasound forward model10.3390/app122412809 ↗
9. Ultrasonic NDT on aluminum bars: An experimental performance comparison of excitation and processing techniques10.1016/j.measurement.2017.10.040 ↗
10. Hybrid coded excitation of the torsional guided wave mode T(0, 1) for oil and gas pipeline inspection10.3390/app12020777 ↗
11. Coded excitation for pulse-echo systems10.1109/TUFFC.2017.2661383 ↗
12. Using coded excitation to maintain signal to noise for FMC+TFM on attenuating materials
13. Ultrasonic attenuation measurements at very high SNR: Correlation, information theory and performance10.1088/1742-6596/457/1/012004 ↗
14. Exploiting pseudorandom sequences to enhance noise immunity for air-coupled ultrasonic nondestructive testing10.1109/TIM.2012.2200409 ↗
15. Simultaneous transmission and reception on all elements of an array: Binary code excitation10.1098/rspa.2018.0831 ↗
16. Application of golay codes to improve the dynamic range in ultrasonic lamb waves air-coupled systems10.1016/j.ndteint.2010.07.005 ↗
17. An improved chirp coded excitation based on compression pulse weighting method in endoscopic ultrasound imaging10.1109/TUFFC.2020.3008920 ↗
18. P2f-6 designing non-linear frequency modulated signals for medical ultrasound imaging
19. Coded excitation for diagnostic ultrasound: a system developer’s perspective10.1109/TUFFC.2005.1406543 ↗
20. Use of modulated excitation signals in medical ultrasound. part i: basic concepts and expected benefits10.1109/TUFFC.2005.1406545 ↗
21. Use of modulated excitation signals in medical ultrasound. part ii: design and performance for medical imaging applications10.1109/TUFFC.2005.1406546 ↗
22. A coded excitation framework for high SNR transcranial ultrasound imaging
23. Research on golay-coded excitation in real-time imaging of high frequency ultrasound biomicroscopy
24. Compound barker-coded excitation for increased signal-to-noise ratio and penetration depth in transcranial ultrasound imaging
25. Coded excitation for crosstalk suppression in multi-line transmit beamforming: Simulation study and experimental validation10.3390/app9030486 ↗
26. Design of orthogonal coded excitation for synthetic aperture imaging in ultrasound systems
27. Complete complementary coded excitation scheme for snr improvement of 2d sparse array ultrasound imaging
28. Use of modulated excitation signals in medical ultrasound. part iii: high frame rate imaging10.1109/TUFFC.2005.1406547 ↗
29. Orthogonal golay codes with local beam pattern correction in ultrasonic imaging10.1109/LSP.2015.2423619 ↗
30. Burrascano · 2015
31. An introduction to matched filters10.1109/TIT.1960.1057571 ↗
32. The optimum bandwidth of chirp signals in ultrasonic applications10.1016/0041-624X(93)90049-6 ↗
33. Crosscorrelation properties of pseudorandom and related sequences10.1109/PROC.1980.11697 ↗
34. Spreading sequences in active sensing: A review10.1016/j.sigpro.2014.07.002 ↗
35. Cheeke · 2012
36. Complementary series10.1109/TIT.1961.1057620 ↗
37. A framework for the construction ofgolay sequences10.1109/TIT.2008.924667 ↗
38. Parker · 2003
39. Coded excitation using TOP-CS sequences for multi-channel low-power ultrasonics10.1016/j.ymssp.2024.111339 ↗