journal article·2020-12

Bridge deck assessment using infrastructure corrosion assessment magnetic method (iCAMM™) technology, a case study of a culvert in Markham city, Ontario, Canada

M. Mosharafi, S.B. Mahbaz, M.B. Dusseault

Publisher page

Abstract

Abstract Steel reinforcement corrosion can result in disastrous bridge failures over time. To manage the human and financial risks associated with such unexpected functional bridge failures, the reinforcements' condition should be quantified using Non-Destructive Testing (NDT) methods. In this case history, the condition of culvert C072's reinforced concrete (RC) bridge structure (located in the north of Markham, Ontario, Canada) is inspected. The inspection, carried out under the supervision of the Corporation of the City of Markham, used a passive magnetic-based NDT technology, the Infrastructure Corrosion Assessment Magnetic Method (iCAMM™). The inspection outcomes demonstrate that the sections close to the south and north ends of the bridge display the most-severe reinforcement anomalies: roughly, a maximum of 20% and 14% of the reinforcement's cross-sectional area loss are detected close to the bridging structure's south and north ends. Additionally, an area in the middle of the bridge is found to have a noticeable anomaly in the reinforcement. The results generated from the magnetic data, collected using an iCAMM™ scanner, are in good agreement with visual-investigation results and the culvert's historical information, such as the concrete's chloride content and compressive strength values, as well as information from a half-cell potential survey. Culvert C072's condition is considered moderately deteriorated and corrective actions are recommended.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Concrete Corrosion and Durability · Non-Destructive Testing Techniques · Infrastructure Maintenance and Monitoring

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. Bond and behavior of composite reinforcing bars in concrete10.1080/03602559508009597 ↗
2. Corrosion assessment of steel bars used in reinforced concrete structures by means of eddy current testing10.3390/s16010015 ↗
3. Comparison of uniform and non-uniform corrosion induced damage in reinforced concrete based on a Gaussian description of the corrosion layer10.1016/j.corsci.2011.05.017 ↗
4. Perkins · 2000
5. Static and fatigue behavior investigation of artificial notched steel reinforcement10.3390/ma10050532 ↗
6. Chloride-induced corrosion on reinforcing steel: from the fundamentals to the monitoring techniques10.1016/S0958-9465(02)00089-6 ↗
7. Comparative studies of experimental and numerical techniques in measurement of corrosion rate and time-to-corrosion-initiation of rebar in concrete in marine environments10.1016/j.cemconcomp.2013.11.001 ↗
8. Structural reliability of concrete bridges including improved chloride-induced corrosion models10.1016/S0167-4730(00)00018-7 ↗
9. Effect of strength and covering on concrete corrosion
10. Steel reinforcement corrosion detection with coaxial cable sensors
11. A fundamental study of polarimetric gb-sar for nondestructive inspection of internal damage in concrete walls10.1002/ecj.11762 ↗
12. Non-destructive testing as a tool in reinforced concrete buildings refurbishments10.1108/02630801111132821 ↗
13. Review of nondestructive testing methods for condition monitoring of concrete structures10.1155/2013/834572 ↗
14. Non-destructive evaluation for corrosion monitoring in concrete: a review and capability of acoustic emission technique10.3390/s150819069 ↗
15. Fatigue resistance of reinforcing steel bars10.1016/j.proeng.2016.01.196 ↗
16. Magnetic Barkhausen noise, metal magnetic memory testing and estimation of the ship plate welded structure stress10.1007/s10921-011-0123-7 ↗
17. Detection and inspection of steel bars in reinforced concrete structures using active infrared thermography with microwave excitation and eddy current sensors10.3390/s16020234 ↗
18. A review of three magnetic NDT technologies10.1016/j.jmmm.2011.08.048 ↗
19. 2020
20. 2020
21. Effect of temperature and stress on residual magnetic signals inferromagnetic structural steel10.1109/TMAG.2016.2613064 ↗
22. Simulation of real defect geometry and its detection using passive magnetic inspection (PMI) method10.3390/app8071147 ↗
23. Detecting defects in steel reinforcement using the passive magnetic inspection method10.2113/JEEG22.2.153 ↗
24. Magnetic mapping of defects in type-II superconductors10.1063/1.4952617 ↗
25. Development of a metal magnetic memory method10.1007/s10556-012-9559-6 ↗
26. Characteristics of magnetic memory signals for medium carbon steel under static tensile conditions10.1007/s11771-005-0020-2 ↗
27. Dusseault
28. Mahbaz · 2016
29. Mosharafi · 2020
30. The non-destructive test of steel corrosion in reinforced concrete bridges using a micro-magnetic sensor10.3390/s16091439 ↗
31. Magnetic detection of corroded steel rebar: reality and simulations10.1016/j.ndteint.2020.102225 ↗
32. Size and location detection of transverse cracks using a passive magnetic method10.1016/j.measurement.2020.107485 ↗
33. GM bluePlan Engineering · 2017
34. 2006
35. 2014
36. 1996
37. Detailed condition survey report
38. 2008
39. Statistical methods to assess the reliability of magnetic data recorded over steel corrosion sites10.1016/j.conbuildmat.2020.120260 ↗