Characterization of electromagnetic properties for durability performance and saturation in hardened cement mortar
Source abstract
Abstract
Electromagnetic (EM) properties—dielectric constant and conductivity are changed with porosity and saturation in cement-based materials. In this paper, dielectric constant and conductivity are measured in cement mortar with 5 different mixture conditions considering saturation. For the same mixture proportions, durability tests including porosity, chloride diffusion, air permeability, sorptivity, and water diffusion are performed. Among the continuously measured EM properties within 5–20 GHz of frequency range for different saturation, results under 60% of saturation which shows stable results are selected and averaged as one value. The averaged measurements utilizing results under 60% of saturation are compared with those from durability tests. Through the normalization using the results of W/C 40% which shows best durability performances, changing ratios of durability characteristics are evaluated with normalized dielectric constant and conductivity. The behaviors of EM properties with different saturation and their relationships with durability performances are studied.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Geophysical Methods and Applications · Concrete and Cement Materials Research · Smart Materials for Construction
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Glanvile J, Nevile A. Prediction of concrete durability. In: Proceedings of the STATS 21st anniversary conference, E&FN SPON, 1995. p. 16–36.
2. Electromagnetic properties of concrete at microwave frequency range
3. Dielectric properties of concrete and their influence on radar testing10.1016/S0963-8695(01)00009-3 ↗
4. Immittance spectra for Portland cement/fly ash-based binders during early hydration10.1016/S0008-8846(98)00209-9 ↗
5. The complex impedance response of fly-ash cement revisited10.1016/j.cemconres.2004.01.013 ↗
6. Characterization and monitoring of cement-based systems using intrinsic electrical property measurements10.1016/S0008-8846(02)00824-4 ↗
7. Micro wave absorption of hardened cement paste10.1016/0008-8846(75)90108-8 ↗
8. Microwave study of hydration of slag cement blends in early period10.1016/0008-8846(95)00103-J ↗
9. Relationships between electrical and physical properties of cement pastes10.1016/0008-8846(74)90023-4 ↗
10. Modeling the electromagnetic properties of concrete
11. Geometrical model of conductive and dielectric properties of partially saturated rocks10.1063/1.335804 ↗
12. Halabe UB. Condition assessment of reinforced concrete structures using electromagnetic waves. Doctoral thesis, Department of Civil Engineering, MIT, Cambridge, 1990.
13. Roddis WMK. Concrete bridge deck assessment using thermography and radar. Master's thesis, Department of Civil Engineering, MIT, Cambridge; 1987.
14. Depth-related variation in conductivity to study cover zone concrete during wetting and drying10.1016/S0958-9465(01)00073-7 ↗
15. Condition monitoring of deteriorating concrete dams using radar10.1016/S0008-8846(00)00496-8 ↗
16. Use of microwaves for damage detection of FRP-wrapped concrete structures10.1061/(ASCE)0733-9399(2002)128:2(172) ↗
17. Kim YJ, Jofre L, De Flaviis FD, Feng MQ. Microwave reflection tomography array for damage detection of concrete structures. In: Proceedings of the IEEE MTT-S international microwave symposium digest, Seattle, WA, 2002.
18. Rhim HC, Kim YJ, Feng MQ, Woo SK, Song YC. Measurements of electromagnetic properties of concrete and fiber reinforced polymer for nondestructive testing. In: US–Korea joint seminar/workshop on smart structures technologies, Sheraton Walker Hill Hotel, Seoul, Korea, 2004.
19. Modeling of pore content in concrete under generic drying wetting conditions
20. Permeability characteristics of carbonated concrete considering capillary pore structure10.1016/j.cemconres.2007.03.011 ↗
21. Study on some factors affecting the results in the use of MIP method in concrete research10.1016/S0008-8846(02)00974-2 ↗
22. Korean Standard, Method of test for compressive strength of concrete-KSF 2405, 2005.
23. Service life prediction of concrete wharves with early-aged crack: probabilistic approach for chloride diffusion10.1016/j.strusafe.2008.03.004 ↗
24. On the mathematics of time-dependent apparent chloride diffusion coefficient in concrete10.1016/j.cemconres.2007.01.006 ↗
25. NORDTEST. Chloride migration coefficient from non-steady-state migration experiments, NT BUILD 492, 1999.
26. The relationship between the compressive strength and air permeability of concrete
27. Analysis of moisture transport in mortar and concrete using sorption–diffusion approach
28. Korea Standard, Determination of the water absorption coefficient of building materials, KS F 2609-1712, 2003.
29. An experimental study on evaluation of compressive strength in cement mortar using averaged electromagnetic properties10.4334/IJCSM.2009.3.1.025 ↗
30. Kwon SJ, Feng MQ, Na UJ. An experimental study on electromagnetic properties in chloride-contaminated cement mortar, ASCE, International Committee, Los Angeles Section. In: 5th international engineering and construction, conference (IECC’5), August 27–29, 2008. p. 673–80.
31. Early-age cracking resistance evaluation of concrete structure
32. Measurement of electromagnetic properties of concrete for nondestructive testing
33. A unified solidification model of hardening concrete composite for predicting the young age behavior of concrete10.1016/S0958-9465(03)00073-8 ↗
34. Maekawa · 1999
35. Modeling of pore content in concrete under generic drying wetting conditions
36. Microwave study of hydrating cement paste at early age10.1016/0008-8846(82)90059-X ↗
37. Use of capacitive and GPR techniques for the non-destructive evaluation of cover concrete10.1016/j.ndteint.2007.06.004 ↗