journal article·2016-06

A simulation study of the spent nuclear fuel cask condition evaluation using high energy X-ray computed tomography

Xin Liu, Hyoung Koo Lee

Publisher page

Abstract

Abstract The dry cask storage time could be much longer (>60 years) for the spent nuclear fuels before final disposition in the United States. The casks have multiple internal components that are designed to provide structural integrity during storage and, in some cases, during transportation. The long-term internal stability of the internals and spent fuel and their cladding is important to maintain the sub-criticality of the fissile materials in the casks. In this study, we propose to develop a high-energy X-ray CT system to examine the integrity of casks and their inner components. With careful system design and advanced image reconstruction techniques, we estimate that a sub-centimeter spatial resolution can be achieved through the simulation study. A complete three-dimension “anatomical” picture of the cask and its inner components can be obtained with a reasonable scanning time.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced X-ray and CT Imaging · Radiation Dose and Imaging · Nuclear Materials and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Chopra OK, Diercks DR, Fabian RR, Han ZH, Liu YY. Managing aging effects on dry cask storage systems for extended long-term storage and transportation of used fuel-revision 2 FCRD-UFD-2014-000476Argonne National Laboratory; 2014.10.2172/1159908 ↗
2. Computerized transverse axial scanning (tomography): part I. Description of system10.1259/0007-1285-46-552-1016 ↗
3. Boone JM, Strauss KJ, Cody DD et al. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. AAPM report no. 204. College Park, MD: American Association of Physicists in Medicine (AAPM); 2011. 28 p.10.37206/143 ↗
4. Computed tomography – an increasing source of radiation exposure10.1056/NEJMra072149 ↗
5. Imaging of concrete structures10.1016/S0963-8695(98)00012-7 ↗
6. Measuring physical density with X-ray computed tomography10.1016/S0963-8695(97)00020-0 ↗
7. Computed tomography with image intensifier: potential use for nondestructive testing and imaging of small objects10.1016/S0963-8695(00)00002-5 ↗
8. Practical cone-beam algorithm10.1364/JOSAA.1.000612 ↗
9. An inversion formula for cone-beam reconstruction10.1137/0143035 ↗
10. A general cone-beam reconstruction algorithm10.1109/42.241876 ↗
11. Exact image reconstruction on PI-lines from minimum data in helical cone-beam CT10.1088/0031-9155/49/6/006 ↗
12. Thresholds for several photo-nuclear reactions10.1103/PhysRev.75.542 ↗
13. Fukahori T, Iwamoto O, Chiba S. Unified description of neutron-, proton- and photon-induced fission cross sections in intermediate energy region. In: Proceedings of the 7th international conference on nuclear criticality safety (ICNC 2003). Tokai-mura, Japan; 2003.
14. A computer code to simulate X-ray imaging techniques10.1016/S0168-583X(00)00185-3 ↗
15. A fast algorithm for voxel-based deterministic simulation of X-ray imaging10.1016/j.cpc.2007.11.008 ↗
16. Region-of-interest (ROI) mode in industrial X-ray computed tomography10.1016/0308-9126(90)92151-P ↗
17. Performance of iterative tomographic algorithms applied to non-destructive evaluation with limited data10.1016/S0963-8695(97)00005-4 ↗
18. Compressed sensing10.1109/TIT.2006.871582 ↗
19. Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets10.1118/1.2836423 ↗
20. Bushberg · 2011