journal article·2014-03

Electrical method for crosstalk cancellation in transducer arrays

A. Bybi, C. Granger, S. Grondel, A.-C. Hladky-Hennion, J. Assaad

Publisher page

Abstract

In this paper, we report a new and simple electrical method to cancel crosstalk in the acoustical arrays. This solution has several advantages compared with that proposed in a previous paper (Bybi et al 2013) [17] where adapted electrical voltages were applied to each neighboring element of the active element in order to reduce the displacement field on their active surface. Firstly, it allows obtaining accurate correction electrical voltages, since it requires average electrical measurements (impedance and current measurements) instead of the displacement measurement in each point at the surface of the radiated element. In addition to this, the method does not need a laser vibrometer which is expensive in terms of time and difficult to use accurately for displacement measurement in water. To demonstrate the ability of the proposed solution an array composed of seven-elements, similar to those used in medical imaging and NDT applications, made of a conventional piezo-ceramic material PZT-27 is fabricated. Then an electrical method based on electromechanical equivalent circuits for piezoelectric materials and motional current measurements is applied. The experimental and numerical results obtained demonstrate the ability of the proposed technique to reduce crosstalk as well as its robustness and ease of implementation.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Ultrasound Imaging and Elastography · Flow Measurement and Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (27)

Show source-provided references
1. Numerical and experimental investigation of kerf depth effect on high-frequency phased array transducer10.1016/j.ultras.2011.08.006 ↗
2. A 30-MHz piezo-composite ultrasound array for medical imaging applications10.1109/58.985706 ↗
3. 1–3 connectivity piezoelectric ceramic-polymer composite transducers made with viscous polymer processing for high frequency ultrasound10.1016/j.ultras.2004.02.008 ↗
4. Development of a 35-MHz piezo-composite ultrasound array for medical imaging10.1109/TUFFC.2006.1588408 ↗
5. Cannata, JM, Williams, JA, Hu, C-H, Shung, KK Development of high frequency linear arrays using interdigital bonded composites. In: Proceedings of the IEEE Ultrasonics Symposium, 2008. p. 686–689.10.1109/ULTSYM.2008.0165 ↗
6. Zhian, Q, Lewin, PA, Bloomfield, PE Variable-frequency multilayer PVDF transducers for ultrasound imaging. In: SPIE Proceedings, 1997, 3037, p. 2–12.10.1117/12.271314 ↗
7. Crosstalk reduction with a micromachined diaphragm structure for integrated ultrasound transducer arrays10.1109/58.166810 ↗
8. Forward-viewing CMUT arrays for medical imaging10.1109/TUFFC.2004.1320749 ↗
9. Radiation from finite phased and focused linear array including interaction10.1121/1.418237 ↗
10. Application of the finite element method to two-dimensional radiation problems10.1121/1.407069 ↗
11. Topology optimization of the kerf fillings in linear phased arrays for therapy10.1121/1.1510531 ↗
12. Cross-talk phenomena in a 1–3 connectivity piezoelectric composite10.1121/1.1804631 ↗
13. Analysis and reduction of the cross talk in micro-machined piezoelectric ultrasonic transducers10.4028/www.scientific.net/KEM.270-273.1071 ↗
14. Lee, W., Roh, Y. Optimal design of a piezoelectric 2D array transducer to minimize the cross talk between active elements. In: Proceedings of the IEEE Ultrasonics Symposium, 2009. p. 2738–2741.10.1109/ULTSYM.2009.5441507 ↗
15. New design of the kerfs of an ultrasonic two-dimensional array transducer to minimize cross-talk10.1143/JJAP.49.07HD06 ↗
16. Numerical technique to reduce cross-coupling in acoustical arrays10.1016/S0041-624X(02)00168-3 ↗
17. Reducing crosstalk in array structures by controlling the excitation voltage of individual elements: a feasibility study10.1016/j.ultras.2013.02.009 ↗
18. An approach for reducing adjacent element crosstalk in ultrasound arrays10.1109/TUFFC.2003.1256316 ↗
19. Reducing inter-element acoustic crosstalk in capacitive micromachined ultrasound transducers10.1109/TUFFC.2007.375 ↗
20. Transfer functions of US transducers for harmonic imaging and bubble responses10.1016/j.ultras.2007.05.002 ↗
21. Wilson · 1988
22. Piezoelectric motor using a (1,1) non-axisymmetric mode10.1016/0041-624X(95)00084-G ↗
23. Auld · 1973 · vol. 1
24. Single crystal PZN/ PT-polymer composites for ultrasound transducer applications10.1109/58.852060 ↗
25. Dependence of electromechanical coupling coefficient on the width-to-thickness ratio plank-shaped piezoelectric transducers used for electronically scanned ultrasound diagnostic systems10.1121/1.383657 ↗
26. Friedrich, W, Kaarmann, H, Lerch, R Finite element modeling of acoustic radiation from piezoelectric phased antennas. In: Proceedings of the IEEE Ultrasonics Symposium, 1990. p. 763–767.10.1109/ULTSYM.1990.171468 ↗
27. ATILA, Finite-Element Software Package for the analysis of 2D & 3D structures based on smart materials. Version 6.0.2 User's Manual, November 2010.