Optimum eddy current excitation frequency for subsurface defect detection in SQUID based non-destructive evaluation
Source abstract
Abstract
Detailed experimental studies have been carried out for the determination of optimum eddy current excitation frequencies for the defects located at different depths below the top surface of an aluminum plate. These subsurface defects were detected by using a highly sensitive superconducting quantum interference device (SQUID) based eddy current non-destructive evaluation (NDE) system. The signal to noise ratio was found to be significantly higher at the optimum excitation frequency, which depended on the depth of the defect. The optimum excitation frequencies have been evaluated for defects located at different depths from 2 to 14 mm below the top surface of the plate. The defect depth was varied in steps of 2 mm, while the overall total thickness of the stack of plates was kept constant at 15 mm. Each defect represented a localized loss of conductor volume, which was 60 mm in length, 0.75 mm in width and 1 mm in height. The experimental results show that the square root of the optimum excitation frequency is inversely proportional to the depth of defect.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Non-Destructive Testing Techniques · Geophysical Methods and Applications · Ultrasonics and Acoustic Wave Propagation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (12)
Show source-provided references
1. SQUIDs for nondestructive evaluation10.1088/0022-3727/30/3/002 ↗
2. Standard method for detection of magnetic defects in aircraft engine discs using a HTS SQUID gradiometer10.1109/77.783857 ↗
3. Novel excitation coils for non-destructive evaluation of non-magnetic metallic structures by high-Tc dc SQUID10.1088/0953-2048/15/6/302 ↗
4. A review of SQUID magnetometry applied to nondestructive evaluation10.1109/20.133898 ↗
5. Nondestructive evaluation of various materials using a SQUID-based eddy-current system10.1109/TASC.2005.850030 ↗
6. Integrated low-temperature superconductor SQUID gradiometers for nondestructive evaluation10.1109/77.621972 ↗
7. Eddy current testing of thick aluminum plates with hidden cracks
8. Baskaran R, Janawadkar MP. Universal dependence of optimum frequency on defect depth for SQUID based eddy current evaluation. In: Proceedings of the national seminar on NDE held at Pune, India, December 9–11, 2004.
9. Analytical solutions to eddy-current probe-coil problems10.1063/1.1656680 ↗
10. SQUIDs—highly sensitive magnetic sensors
11. Development of SQUID based system for non-destructive evaluation10.1109/TASC.2007.902112 ↗
12. Development of SQUID based non-destructive evaluation system for detecting fatigue induced transformation of δ-ferrite to non-magnetic phases10.1016/j.ndteint.2006.10.009 ↗