X-ray modeling of realistic synthetic radiographs of thin titanium welds
Source abstract
Abstract
This paper describes the addition and benefits of an improved detector model and a radiographic noise model to a previously developed mathematical model of a specific radiographic system. The model intentions are to simulate realistic synthetic radiographs of thin laser welded titanium welds and to act as an X-ray projection kernel in an image analysis algorithm. Both these objectives put high demands on low calculation time and to accomplish this a number of simplifications have been done. An evaluation of the tradeoff when using the simplifications is essential and simulations of specific geometries and the radiographic inspection procedure are used for this purpose. As verification the simulated radiographs are compared to real digital radiographs relevant for the proposed applications.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging · Digital Radiography and Breast Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (23)
Show source-provided references
1. Lindgren E, Wirdelius H. Separation of geometrical- and defect information in digital radiographs using wavelet techniques. In: 20th ISABE conference 2011 proceedings. AIAA; 2011. p. 1616:1–9.
2. X-ray modeling for industrial applications10.1016/S0963-8695(00)00019-0 ↗
3. Sindbad: from cad model to synthetic radiographs
4. Tabary J, Glière A. Coupling photon monte carlo simulation and cad software. Application to X-ray nondestructive evaluation. In: International conference on advanced Monte Carlo for radiation physics, particle transport simulation and applications. Lisbon, Portugal; 2000. p. 23–6.10.1007/978-3-642-18211-2_73 ↗
5. Deterministic simulation of first-order scattering in virtual X-ray imaging10.1016/j.nimb.2004.01.001 ↗
6. Modelling of a high resolution digital radiographic system and development of a filtering technique based on wavelet transforms10.1016/j.ndteint.2003.09.001 ↗
7. Salvat · 2008
8. Radiographs simulation using system MTF
9. Bielajew A. Howfar and hownear: geometry modeling for Monte Carlo particle transport. Report PIRS-0341. Ottawa, Canada: National Research Council of Canada; 1996.
10. A computer code to simulate X-ray imaging techniques10.1016/S0168-583X(00)00185-3 ↗
11. Determination of point spread function for a flat-panel X-ray imager and its application in image restoration10.1016/j.nima.2006.01.136 ↗
12. Random transparency targets for modulation transfer function measurement in the visible and infrared regions10.1117/12.190433 ↗
13. Semiempirical model for generating tungsten target X-ray spectra10.1118/1.596709 ↗
14. Calculation of X-ray spectra emerging from an X-ray tube. Part II. X-ray production and filtration in X-ray targets10.1118/1.2734726 ↗
15. Correction for beam hardening artefacts in computerised tomography
16. Berger M, Hubbell J, Seltzer S, Chang J, Coursey J, Sukumar R, et al. Xcom: photon cross sections database (version 1.5); 2010 〈http://www.nist.gov/pml/data/xcom/〉.
17. Experimental benchmarks of the Monte Carlo code penelope10.1016/S0168-583X(03)00453-1 ↗
18. Analytical cross sections for monte carlo simulation of photon transport10.1016/0969-806X(94)90053-1 ↗
19. Halmshaw · 1995
20. Knoll · 2000
21. A note on the generation of random normal derivates10.1214/aoms/1177706645 ↗
22. Influence of X-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography10.1088/0031-9155/37/6/004 ↗
23. Dainty · 1974