journal article·2021-12

Analysis of angular dependent spatial frequency response of Digital Coplanar Translational Laminography

Weslley Silva, Uwe Zscherpel, Uwe Ewert, Ricardo Lopes

Publisher page

Abstract

Abstract Digital Coplanar Translational Laminography (CTL) is a radiographic imaging technique that permits the visualization of structural details and discontinuities in the object of interest after 3D reconstruction from multiple projections. This technique becomes quite competitive regarding to computed tomography in situations of arrangements in which no complete rotation of the X-ray source - detector system around the object of interest is accessible or in cases where the part to be inspected has a high geometric asymmetry. The literature does not show many studies about image quality for different laminographic reconstructions and scan geometries. Different methodologies for measuring the Modulation Transfer Function (MTF) as a key image quality parameter for the aforementioned technique are applied. The MTF was measured using different approaches, pre-sampled MTF or sampled MTF, both based on the Fourier Transform-Magnitude Spectrum or the square wave MTF using line pattern gauges. A sample known as Siemens Star with a converging line pattern was used to measure the circular square wave MTF. This circular MTF provides information on the direction dependent contrast transfer related to the measurement conditions, the reconstruction algorithms and the translational scan direction. For this purpose, several MTF measurements were performed in multiple angular directions. Beyond it, reconstructions were performed using different algorithms (Filtered Shifted Average) and an iterative one (MART – Multiplicative Algebraic Reconstruction Technique). Image quality analysis were done for both reconstruction methods. MART showed an image quality improvement for challenging conditions for laminographic arrangements, such as for a low number of projections (down to 25 for this study, considered as limited view, limited angle reconstruction). Additionally, a Gadolinium gauge with parallel line patterns within a range from 10 μm to 1000 μm was used to compare the square wave MTF with the sine MTFs, measured by the different techniques mentioned above. The results show that the MTF techniques presented are equivalent in this study. The results obtained for this Gadolinium plate showed a good agreement between MTF10% and SRbimage measurements. The methodology presented here is used for the characterization of the frequency dependent spatial resolution of measurements obtained from different laminographic reconstruction techniques and scan geometries. Finally, from the acquisitions and reconstructions obtained with the Siemens Star, cross laminographic images were calculated in order to improve the direction dependent sensitivity. The results showed a better detectability for cross laminographic images in comparison to unidirectional coplanar translational laminographic images covering dead zones.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Digital Radiography and Breast Imaging · Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Ewert · 1995 · 218
2. Essential parameters and conditions for optimum image quality in digital radiology
3. Andre bocage (1892-1953) – French tomographer10.1001/jama.1965.03090030055021 ↗
4. O'Brien · 2016
5. Ewert · 2017
6. Ewert · 2015 · 22
7. Schorr · 2016
8. Cant · 2016
9. X-ray imaging techniques for inspection of composite pipelines10.1016/j.micron.2021.103033 ↗
10. Schumacher · 2017
11. Filter assessment applied to analytical reconstruction for industrial third-generation tomography
12. 3D X-ray inspection system for helicopter rotor blades
13. Laminographic inspection of large carbon fibre composite aircraft-structures at airbus
14. X-ray tomographic in-service-testing of circumferential pipe welds – the European project TomoWeld
15. Real-time radiography for observation of crack growth during GTA welding
16. Digital computed laminography and tomosynthesis- functional principles and industrial applications
17. Liu
18. 2013
19. Oliveira · 2010
20. 2018
21. Azeredo · 2016
22. Spatial resolution characterization of a X-ray microCT system10.1016/j.apradiso.2014.08.014 ↗
23. Alekseychuk · 2013
24. Essential parameters for the visibility of IQIs and small indications in digital radiography
25. Determining the spatial resolution in computed tomography – comparison of MTF and line-pair structures
26. 2017
27. 2003
28. QA-distribution: a set of plugin applications for ImageJ
29. 2015