journal article·2025-06Open access

High-quality, low-quantity: A data-centric approach to deep learning performance optimization in digital X-Ray radiography

Bata Hena, Ziang Wei, Clemente Ibarra-Castanedo, Xavier Maldague

Abstract

The accuracy of identifying defects using specialized deep learning models can be affected by the circumstances in which the training data is curated. This is especially evident in digital X-ray radiography, where the depiction of flaws is significantly impacted by the exposure conditions. This study examines the effect of curating high-quality data on deep learning models. The variation in contrast-to-noise ratio (CNR), which is a crucial metric of image quality between features of interest and an adjacent normal background, has been found to be a key factor in model generalization in digital X-ray radiography applications. By making systematic alterations to exposure conditions during data curation, it was possible to obtain several representations of flaws in each test component with varying contrast-to-noise ratios (CNR) in the resultant radiographs. To evaluate the efficacy of the model under various conditions, two distinct datasets were curated. Dataset 1 was obtained by acquiring images with a consistent exposure setting on 140 test samples. The samples contained 4 morphologically distinct classes of flat bottom holes with seven different depths and sizes. The contrast-to-noise ratio (CNR) representations of flaws in this dataset can be attributed only to differences in depth in Dataset 1. Additionally, Dataset 2 was curated with an expanded range of CNR values by methodically adjusting exposure settings during image acquisitions. Hence, only 42 % of the test pieces from Dataset 1, which had three distinct depths of flat bottom holes, were used. Each of the two datasets was used to separately train YOLOv8 for instance segmentation and U-net for multi-class semantic segmentation. Each model was trained under the same conditions, and their performances were assessed using test sets from both dataset groups. The model trained on Dataset 1 exhibited a notable decline in performance when evaluated on test sets from Dataset 2, suggesting a lack of generalization ability. Conversely, the model that was trained using Dataset 2 consistently achieved high accuracy on both test sets, demonstrating impressive performance and successful generalization. This work shows that the generalization abilities of deep learning models may be improved by varying the contrast-to-noise ratio (CNR) of features in the training data. This finding paves the way for practical applications in digital X-ray radiography.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Medical Imaging Techniques and Applications · Advanced X-ray and CT Imaging · Radiomics and Machine Learning in Medical Imaging

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (48)

Show source-provided references
1. Alloy development and process innovations for light metals casting10.1016/j.jmatprotec.2022.117606 ↗
2. Review on additive manufacturing and non-destructive testing10.1016/j.jmsy.2022.12.005 ↗
3. Deploying machine learning for radiography of aerospace welds10.1007/s10921-023-01041-w ↗
4. NON-DESTRUCTIVE testing for quality control in automotive industry10.33564/IJEAST.2022.v07i01.054 ↗
5. Advancements in radiographic evaluation through the migration into NDE 4.010.1007/s10921-021-00749-x ↗
6. Automated defect detection and decision-support in gas turbine blade inspection10.3390/aerospace8020030 ↗
7. Defect detection and classification in welding using deep learning and digital radiography
8. Review on computer aided weld defect detection from radiography images10.3390/app10051878 ↗
9. Deep learning in automated ultrasonic NDE – developments, axioms and opportunities10.1016/j.ndteint.2022.102703 ↗
10. Influence of data splitting on performance of machine learning models in prediction of shear strength of soil
11. PUMA: performance unchanged model augmentation for training data removal10.1609/aaai.v36i8.20846 ↗
12. Investigation on the effect of data quality and quantity of concrete cracks on the performance of deep learning-based image segmentation10.1016/j.eswa.2023.121686 ↗
13. Training data influence analysis and estimation: a survey10.1007/s10994-023-06495-7 ↗
14. A comprehensive survey on data augmentation
15. A survey of automated data augmentation algorithms for deep learning-based image classification tasks10.1007/s10115-023-01853-2 ↗
16. 2024
17. A systems approach to estimating the uncertainty limits of X-ray radiographic metrology10.1115/1.4049421 ↗
18. ISO 17636-2:2022(en), Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors.” Accessed: Jun. 28, 2024. [Online]. Available: https://www.iso.org/obp/ui/#iso:std:iso:17636:%202:ed-2:v2:en.
19. Deep learning neural network performance on NDT digital X-ray radiography images: analyzing the impact of image quality parameters—an experimental study10.3390/s23094324 ↗
20. Automated defect recognition for additive manufactured parts using machine perception and visual saliency10.1089/3dp.2021.0224 ↗
21. Human Reliability Assessment method applied to investigate human factors in NDT - the case of the interpretation of radiograms in the French nuclear sector10.58286/28268 ↗
22. Defect detection in welding radiographic images based on semantic segmentation methods10.1016/j.measurement.2021.110569 ↗
23. Deep neural networks based approach for welded joint detection of oil pipelines in radiographic images with Double Wall Double Image exposure10.1016/j.ndteint.2019.05.002 ↗
24. Aluminum casting inspection using deep object detection methods and simulated ellipsoidal defects10.1007/s00138-021-01195-5 ↗
25. Self-attention guided model for defect detection of aluminium alloy casting on X-ray image10.1016/j.compeleceng.2020.106821 ↗
26. A survey of uncertainty in deep neural networks10.1007/s10462-023-10562-9 ↗
27. A survey on deep learning tools dealing with data scarcity: definitions, challenges, solutions, tips, and applications10.1186/s40537-023-00727-2 ↗
28. S. Yang, Y. Dong, R. Ward, I. S. Dhillon, S. Sanghavi, and Q. Lei, “Sample efficiency of data augmentation consistency regularization”.
29. Automated damage and defect detection with low-cost X-ray radiography using data-driven predictor models and data augmentation by X-ray simulation
30. A review of synthetic and augmented training data for machine learning in ultrasonic non-destructive evaluation10.1016/j.ultras.2023.107041 ↗
31. Towards enhancing automated defect recognition (ADR) in digital X-ray radiography applications: synthesizing training data through X-ray intensity distribution modeling for deep learning algorithms10.3390/info15010016 ↗
32. Data augmentation of X-ray images in baggage inspection based on generative adversarial networks10.1109/ACCESS.2020.2992861 ↗
33. Data augmentation for medical imaging: a systematic literature review10.1016/j.compbiomed.2022.106391 ↗
34. Deep convolutional neural network for weld defect classification in radiographic images10.1016/j.heliyon.2024.e30590 ↗
35. Modified histogram equalization for improved CNN medical image segmentation10.1016/j.procs.2023.10.295 ↗
36. Analysis for diagnosis of pneumonia symptoms using chest X-ray based on MobileNetV2 models with image enhancement using white balance and contrast limited adaptive histogram equalization (CLAHE)10.1016/j.bspc.2023.105857 ↗
37. Enhanced medical image segmentation using CNN based on histogram equalization
38. ALARA principles
39. Automated defect recognition on X-ray radiographs of solid propellant using deep learning based on convolutional neural networks10.1007/s10921-021-00750-4 ↗
40. A deep learning-based scatter correction of simulated X-ray images10.3390/electronics8090944 ↗
41. Standards
42. C. Bellon, A. Deresch, and G.-R. Jaenisch, “Radiography simulation with aRTist – combining analytical and Monte Carlo methods”.
43. Effect of x-ray tube voltage variation to value of contrast to noise ratio (CNR) on computed tomography (CT) Scan at RSUD Bali Mandara10.53730/ijpse.v6n2.9656 ↗
44. Radiation exposure factors optimization of X-ray digital radiography for watermarked art pottery inspection
45. Microsoft COCO: common objects in context
46. U-net: convolutional networks for biomedical image segmentation
47. API design for machine learning software: experiences from the scikit-learn project
48. Adam: a method for stochastic optimization