Abstract We present new methods to optimise industrial computed tomography (CT) scanning process. The methods were applied on CT systems—with high-energy X-ray tube sources (>400 keV)—using cross-sectional images for volume digitalisation. Commonly the distances between all cross-sectional slices for volume data acquiring are constant. We developed a new adaptive CT scanning method, which optimises the location of the cross-sectional images with respect to object geometry. The optimisation strategy depends on the statistical evaluation of object mesh models (e.g. STL from CAD). We developed a software prototype that implements the new methods. First tests, applied on commercial objects, lead to a reduction in number of necessary slices of up to 50%. The accuracy of the digital volume model formed by the adaptive scanning method is comparable to the one retrieved by the equidistant scanning method.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Medical Imaging Techniques and Applications · Digital Image Processing Techniques · Advanced X-ray and CT Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (8)
Show source-provided references
1. Kak · 1988
2. Practical cone-beam algorithm10.1364/JOSAA.1.000612 ↗
3. Obrist · 2001
4. Flisch A, Wirth J, Zanini R, Breitenstein M, Rudin A, Wendt F, Mnich F, Golz R. Industrial computed tomography in reverse engineering applications. DGZfP—Proceedings BB 67-CD Paper 8, Computerized Tomography for Industrial Applications and Image Processing in Radiology, March 15–17, 1999, Berlin, Germany.
5. Foley · 1990
6. Gonzales · 2002
7. An analysis of histogram-based thresholding algorithms10.1006/cgip.1993.1040 ↗
8. Obrist A, Flisch A, Hofmann J. Point cloud reconstruction with sub-pixel accuracy by slice-adaptive thresholding of X-ray computed tomography images. NDT&E international; 2003. In press.10.1016/j.ndteint.2003.11.002 ↗