Correction algorithm for environmental scattering in industrial computed tomography
Source abstract
Abstract
Abstract Scattering of X-ray photons in the environment causes artefacts in high-energy X-ray computed tomography (CT). Here, an analytical correction formula applied to transmission images is presented and experimentally validated on data from a 450 kV cone-beam CT-system. This method increases the contrast of CT-images from a large aluminium step cylinder by a factor exceeding 2.5. For complex objects, the procedure reduces the variance of the attenuation values for the material given an optimal correction parameter. For the considered source parameters, this correction parameter could be derived from the measurement data by a simple procedure with a correlation coefficient of 0.996±0.005.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Radiation Dose and Imaging
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Kak · 1988
2. Practical cone-beam algorithm10.1364/JOSAA.1.000612 ↗
3. Detection of stress whitening in plastics with the help of X-ray dark field imaging10.1016/j.polymertesting.2013.06.008 ↗
4. Characterization of multi-scale microstructural features in opalinus clay10.1016/j.micromeso.2012.11.029 ↗
5. Quantitative comparison of the eye formation in cheese using radiography and computed tomography data10.1016/j.idairyj.2012.12.007 ↗
6. Accuracy of industrial computed tomography measurements: experimental results from an international comparison10.1016/j.cirp.2012.03.021 ↗
7. Combining deterministic and Monte Carlo calculations for fast estimation of scatter intensities in CT10.1088/0031-9155/51/18/008 ↗
8. Monte Carlo simulations of a high-resolution x-ray CT system for industrial applications10.1016/j.nima.2007.09.012 ↗
9. Modelling of scintillator based flat-panel detectors with Monte-Carlo simulations10.1088/1748-0221/6/01/C01065 ↗
10. Reducing environmental scattering in industrial computed tomography by system redesign10.1016/j.ndteint.2013.04.005 ↗
11. An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT10.1088/0031-9155/54/12/016 ↗
12. Reducing non-linear artifacts of multi-material objects in industrial 3D computed tomography10.1016/j.ndteint.2007.12.001 ↗
13. Empirical beam hardening correction (ebhc) for CT10.1118/1.3477088 ↗
14. Schuetz P, Miceli A, Flisch A, Jerjen I, Hofmann J, Sennhauser U. Strategies for the reduction of environmental scattering in x-ray computed tomography. In: Conference on industrial computed tomography. Wels; 2012.10.1016/j.ndteint.2013.04.005 ↗