Experimental Evaluation of Undersampling Schemes for Electron Tomography of Nanoparticles
Source abstract
Abstract
Abstract One of the emerging challenges in the field of 3D characterization of nanoparticles by electron tomography is to avoid degradation and deformation of the samples during the acquisition of a tilt series. In order to reduce the required electron dose, various undersampling approaches have been proposed. These methods include lowering the number of 2D projection images, reducing the probe current during the acquisition, and scanning a smaller number of pixels in the 2D images. A comparison is made between these approaches based on tilt series acquired for a gold nanoparticle.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Advanced Electron Microscopy Techniques and Applications · Force Microscopy Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Electron Microscopy for Materials Science (EMAT) University of Antwerp Groenenborgerlaan 171 2020 Antwerp Belgium
Funding
Fonds Wetenschappelijk Onderzoek
References (48)
Show source-provided references
1. 10.1021/jp991764810.1021/jp9917648 ↗
2. 10.1021/jp020928910.1021/jp0209289 ↗
3. 10.1021/cr03069810.1021/cr030698 ↗
4. 10.1016/j.ccr.2005.01.03010.1016/j.ccr.2005.01.030 ↗
5. 10.2217/17435889.2.5.68110.2217/17435889.2.5.681 ↗
6. 10.1021/ar700280410.1021/ar7002804 ↗
7. 10.1016/j.addr.2008.03.01610.1016/j.addr.2008.03.016 ↗
8. 10.1039/C1CS15237H10.1039/C1CS15237H ↗
9. 10.1002/anie.20130044110.1002/anie.201300441 ↗
10. 10.1038/nature0097210.1038/nature00972 ↗
11. 10.1103/PhysRevLett.102.09610110.1103/PhysRevLett.102.096101 ↗
12. 10.1016/S0304-3991(03)00105-010.1016/S0304-3991(03)00105-0 ↗
13. 10.1038/nmat240610.1038/nmat2406 ↗
14. 10.1002/anie.20140105910.1002/anie.201401059 ↗
15. 10.1557/mrs.2016.13810.1557/mrs.2016.138 ↗
16. 10.1557/mrs.2016.13410.1557/mrs.2016.134 ↗
17. Dudgeon D. E. · IEEE Commun. Mag. · 1985 · 23 · 63
18. 10.1016/0022-5193(72)90180-410.1016/0022-5193(72)90180-4 ↗
19. 10.1016/j.ultramic.2009.01.00910.1016/j.ultramic.2009.01.009 ↗
20. 10.1109/TIP.2011.213166110.1109/TIP.2011.2131661 ↗
21. 10.1016/j.ultramic.2011.11.00410.1016/j.ultramic.2011.11.004 ↗
22. 10.1016/j.ultramic.2013.03.01910.1016/j.ultramic.2013.03.019 ↗
23. 10.1093/jmicro/dfp05210.1093/jmicro/dfp052 ↗
24. 10.1063/1.494308610.1063/1.4943086 ↗
25. Stevens A. · Appl. Phys. Lett. · 2018 · 112 · 043104‐1
26. 10.1088/0266-5611/23/3/00810.1088/0266-5611/23/3/008 ↗
27. 10.1006/jsbi.1997.392510.1006/jsbi.1997.3925 ↗
28. 10.1016/j.patcog.2005.12.00910.1016/j.patcog.2005.12.009 ↗
29. Vonesch C. · 2011 · 1950
30. 10.1016/j.jsb.2012.01.00310.1016/j.jsb.2012.01.003 ↗
31. 10.1017/S143192761300472810.1017/S1431927613004728 ↗
32. 10.1002/mrm.2139110.1002/mrm.21391 ↗
33. 10.1109/MSP.2007.91472810.1109/MSP.2007.914728 ↗
34. 10.1016/j.ultramic.2017.04.00310.1016/j.ultramic.2017.04.003 ↗
35. 10.1109/LSP.2012.218592910.1109/LSP.2012.2185929 ↗
36. den Broek W. · IEEE Trans. Comput. Imaging
37. 10.1109/TSP.2010.204999710.1109/TSP.2010.2049997 ↗
38. 10.1038/nmat346210.1038/nmat3462 ↗
39. 10.1002/ppsc.20180005110.1002/ppsc.201800051 ↗
40. 10.1109/83.98895310.1109/83.988953 ↗
41. Takita K. · IEICE Trans. Fundam. Electron. Commun. Comput. Sci. · 2003 · 86 · 1925
42. 10.1007/978-3-540-74260-9_1910.1007/978-3-540-74260-9_19 ↗
43. Yan H. · Proc Br. Mach. Vis. Conf. · 2008 · 2008 · 104.1
44. 10.1016/j.ultramic.2015.05.00210.1016/j.ultramic.2015.05.002 ↗
45. 10.1007/s10851-010-0251-110.1007/s10851-010-0251-1 ↗
46. 10.1088/0031-9155/57/10/306510.1088/0031-9155/57/10/3065 ↗
47. 10.1186/s40679-015-0007-510.1186/s40679-015-0007-5 ↗
48. 10.1109/TSMC.1979.431007610.1109/TSMC.1979.4310076 ↗