journal article·2012-08

Performance Assessment of Probes Dedicated to the Monitoring of Surface Particle Contamination

Isabelle Tovena Pecault, François Gensdarmes, Guillaume Basso, Francoise Sommer

Publisher page

Abstract

Abstract Surface probes, based on airflow particle detachment coupled with optical particle counter, are actually available to measure the particle cleanliness of surfaces in cleanroom. No reliable data exits dealing with the performance assessment of these probes in unstuck and counting particles deposited on surfaces. This work presents a method for determining the efficiency of instruments dedicated to particle surface cleanliness measurements. The method is based on the realisation of standard particle deposits by sedimentation and analysis of whole of the contaminated surface by microscopy combined with a micrometric displacement bench. The method is used to assess a trial surface probe with 30 μm and 80 μm glass beads deposited on transparent (glass) or opaque (aluminium) surfaces at concentrations ranging from 1 particle·cm–2 to 50 particles·cm–2. The results obtained show that the overall efficiency of the instrument tested is less than 5 %. The detailed analysis of results shows that this low value is mainly due to poor efficiency of sampling and detection of particles in the optical counter. When analysed in terms of particle detachment efficiency, the results agree qualitatively with a force balance analysis taking into account the friction by airflow and the distribution of adhesion forces of glass particles to glass substrates or rough aluminium substrates. Such result shows that airflow based surface probes for particle cleanliness measurements should be systematically qualified for representative conditions of operations whereas analytical microscopy measurements could be considered as reference.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Particle Dynamics in Fluid Flows · Advanced Sensor Technologies Research · Infection Control and Ventilation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. The effect of surface cleanliness of optical elements on their radiation resistance.
2. S. Palmier I. Tovena R. Courchinoux J. L. Rullier B. Bertussi J. Y. Natoli L. Servant D. Talaga Laser damaged optics induced by chromium particle contamination.Annual Symposium on optical materials for high power lasers: Boulder damage XXXVI.Colorado‐USA – September2004.
3. ISO 14644‐1 Cleanrooms and associated controlled environments Part 1: classification of cleanroom air cleanliness 1999.
4. ISO 14644‐9 Cleanrooms and associated controlled environments Part 9: classification of surface particle cleanliness 2010.
5. IEST 1246 D product cleanliness levels and contamination control program 2000.
6. US Patent 5 253 538 filed by DRYDEN: Method and device for quantifying particles on surface 1993.
7. EN 1822 Air filter test method for testing high efficiency particulate filters 2009.
8. Small particle adhesion: measurement and control.
9. 10.1088/0957-4484/4/2/00210.1088/0957-4484/4/2/002 ↗
10. L. P. DeMejo D. S. Rrimai K. L. Mittal Fundamentals of adhesion and interfaces VPS Utrecht the Netherlands. Ed. by Mittal 1995 pp. 35–48.
11. 10.1016/j.powtec.2006.12.01110.1016/j.powtec.2006.12.011 ↗
12. 10.1016/0021-8502(94)00139-P10.1016/0021-8502(94)00139-P ↗