journal article·2006-10

Mapping of Residual Oil and Water Saturation in Porous Media by Means of Digital X‐ray Laminography

Eugene I. Palchikov, Yury A. Schemelinin, Anton G. Skripkin, Dmitry Yu. Mekhontsev, Nikolay A. Kondratiev

Publisher page

Abstract

Abstract The possibility of applying a digital X‐ray laminography method to the example of mapping the fluid distribution in porous media is studied. The study is performed on the basis of a system which models the process of oil displaced by water and gas as occurs in oil field development. Two methods of tomographic section recovery are discussed: geometric and algebraic, and their application for different specimen structures is made. It is shown that when scanning with steps of 25 μm, 100 μm, 250 μm, or 2 mm it is possible to determine the distribution of concentrations of heterogeneities for multiphase fluid inside a porous core sample layer, giving advantages compared to simple shadow pictures.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Enhanced Oil Recovery Techniques · Hydrocarbon exploration and reservoir analysis · Reservoir Engineering and Simulation Methods

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (11)

Show source-provided references
1. Core Laboratories.AXRP‐300 Automated X‐Ray Relative Permeability System.2005 2015 McKenzie Suite 106 Carrollton Texas 75006 USA.http://www.corelab.com/coreinst/pdf/advanced_rock/axrp‐300.pdf.
2. Coretest Systems Inc.The XRSC‐198 Two or Three‐Phase X‐ray Core Flood Scanning System.2005400 Woodview Av. Morgan Hill CA 95037 USA.http://www.coretest.com/pdf/xrsc‐198.pdf.
3. Temco Inc.The Linear X‐Ray Core Scanning System.2005 4616 North Mingo Tulsa OK 74117‐5901 USA.http://www.temco.com/tempstuff/xray1.htm.
4. Vinci Technologies SA.X‐ray relative permeameter XRP500.2005 27 B rue du Port – 92022 Nanterre (France).http://www.vinci‐technologies.com/images/Produits/D70C7A75‐7F10‐40c9‐B6BC‐B4BC6EABD391.PDF.
5. H. J. Vinegar S. L. Wellington Tomographic Imaging of Three‐Phase Flow Experiments Rev. Sci. Instrum.1987 58.10.1063/1.1139522 ↗
6. E. M. Withjack C. Devier G. Michael The Role of X‐Ray Computed Tomography in Core Analysis.SPE PTS Labs. SPE 83467 article. Copyright2003SPE Inc.10.2118/83467-MS ↗
7. A. S. Besov A. G. Skripkin Yu. A. Schemelinin E. I. Palchikov A. N. Cheremisin D. Yu. Mekhontsev Researching the dynamics of movement of gas‐liquid mixture in a porous medium by means of low‐angle tomography.Proceedings of ICMF‐2004. Fifth International Conference on Multiphase Flow.Yokohama Japan May 30 – June 4 2004. Paper No 140.
8. E. I. Palchikov S. V. Sukhinin A. Yu. Burlev E. R. Bartuli D. Yu. Mekhontsev M. A. Romanjuta K. S. Seleznev X‐ray Tomographic Flow Visualization of Multiphase Fluid Mixture in Porous Media.Seventh Triennial International Symposium on Fluid Control Measurement and Visualization.2003Sorrento Italy August 25–28 2003 FLUCOME'03. Paper No 101.
9. 10.2118/21433-PA10.2118/21433-PA ↗
10. GeoLogika CJSC Relative Permeability Measuring System. Accessories.2005Building 2 17 Lavrentiev Ave. Novosibirsk 630090 Russia.http://www.geologika.ru/eng/products.php.
11. S. Gondrom Digital computed laminography and tomosynthesis – functional principles and industrial applications. International Symposium on Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15 – 17 1999Berlin Germany. Proceedings BB 67‐CD published by DGZfP.http://www.ndt.net/article/v04n07/bb67_11/bb67_11.htm