Theoretical investigation on submicron particle penetration through circular tubes inside a porous medium
Source abstract
Abstract
The analytical infinite series solution of submicron particle transport in a circular tube bounded by a porous wall, such as a pinhole, is determined under the slip velocity boundary condition, and the solution is verified by using the experimental data in the previous studies for the specific cases. The results show that particle penetration rate increases with the increase of the porous parameter, the axial pressure drop, and the pinhole radius, whereas it decreases with increasing the pinhole length. The penetration rate of nano-particles are more sensitive to the variation of these parameters. However, the differences between the penetrations of particles ranging from 0.3 μm to 1 μm are not evident because the diffusion becomes weak gradually in this size range. In addition, a further comparison is performed between the analytical solution and the existing studies, and approximate expressions are presented for accurate calculation of particle penetration rate through pinholes appearing in porous materials including filter devices and masks.
Source: expertdata · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Aerosol Filtration and Electrostatic Precipitation · Particle Dynamics in Fluid Flows · Urban Stormwater Management Solutions
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. Analytical approximation to the fully developed concentration profile of diffusive aerosol particles in laminar flow in a circular tube10.1016/j.jaerosci.2010.02.003 ↗
2. About the Beavers and Joseph boundary condition10.1007/s11242-009-9435-9 ↗
3. Boundary condition at a naturally permeable wall10.1017/S0022112067001375 ↗
4. Laminar flow in channels with porous walls10.1063/1.1721476 ↗
5. Clean rooms—Another fire protection problem10.1007/BF02588987 ↗
6. Quantitative respirator fit testing: Dynamic pressure versus aerosol measurement10.1080/15298668891380114 ↗
7. Boundary conditions at a planar fluid-porous interface for a Poiseuille flow10.1016/j.ijheatmasstransfer.2005.12.010 ↗
8. Characteristics of face seal leakage in filtering facepieces10.1080/15298669291360120 ↗
9. Particle deposition from duct flows by combined mechanisms10.1080/02786829308959646 ↗
10. Filter and leak penetration characteristics of a dust and mist filtering facepiece10.1080/15298669091370275 ↗
11. Crowe · 2012
12. Diffusion and sedimentation of aerosol particles from Poiseuille flow in pipes10.1016/0021-8502(73)90092-X ↗
13. Flow in a horizontal circular cylinder bounded by a porous medium10.1007/BF01227989 ↗
14. Friedlander · 2000
15. Ghiaasiaan · 2011
16. Diffusion from a stream flowing through a cylindrical tube
17. Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin head form
18. Performance of dust respirators with facial seal leaks: II. Predictive model10.1080/15298668791385688 ↗
19. Performance of dust respirators with facial seal leaks: I. Experimental10.1080/15298668791385679 ↗
20. Particle size-dependent leakage and losses of aerosols in respirators10.1080/15298668791385697 ↗
21. Diffusion of aerosols from a stream flowing through a cylindrical tube10.1016/0021-8502(75)90005-1 ↗
22. Laminar flow in a porous channel with large wall suction and a weakly oscillatory pressure10.1063/1.1445419 ↗
23. Stokes flow past periodic rows of porous cylinders10.1134/S0040579506050034 ↗
24. Treatment of losses of ultrafine aerosol particles in long sampling tubes during ambient measurements10.1016/j.atmosenv.2008.09.003 ↗
25. Landau · 1987
26. Respirator leak detection by ultrafine aerosols: A predictive model and experimental study10.1080/02786829308959617 ↗
27. Particulate matter concentrations and their related metal toxicity in rural residential environment of semi-arid region of India10.1016/j.atmosenv.2012.11.002 ↗
28. Slip condition on the surface of a model fibrous porous medium10.1134/S1063785009030158 ↗
29. Penetration of nanoparticles through fibrous filters perforated with defined pinholes10.1016/j.jaerosci.2009.04.010 ↗
30. An approximate analytical solution for the fluid dynamics of laminar flow in a porous tube10.1016/S0376-7388(01)00634-2 ↗
31. Nield · 1992
32. O’Brien · 1937
33. Efficacy and safety of disinfectants for decontamination of N95 and SN95 filtering facepiece respirators: A systematic review10.1016/j.jhin.2020.08.005 ↗
34. Flow through a pipe with a porous wall10.1115/1.4009893 ↗
35. Olver · 2010
36. Respiratory effects are associated with the number of ultrafine particles10.1164/ajrccm.155.4.9105082 ↗
37. Relationships between fine particulate air pollution, cardiometabolic disorders, and cardiovascular mortality10.1161/CIRCRESAHA.116.305060 ↗
38. An investigation into the efficiency of disposable face masks10.1136/jcp.33.11.1086 ↗
39. Thermophoretically augmented mass-, momentum- and energy-transfer rates in high particle mass loaded laminar forced convection systems10.1016/0009-2509(88)80013-7 ↗
40. Which specific causes of death are associated with short term exposure to fine and coarse particles in Southern Europe? Results from the MED-PARTICLES project10.1016/j.envint.2014.02.013 ↗
41. Occupational risk management of engineered nanoparticles10.1080/15459620801907840 ↗
42. Is daily mortality associated specifically with fine particles?10.1080/10473289.1996.10467528 ↗
43. On the separation of air-borne particles by diffusion10.1016/0021-8502(72)90088-2 ↗
44. Diesel soot mass calculation in real-time with a differential mobility spectrometer10.1016/j.jaerosci.2006.10.001 ↗
45. Diffusion of aerosols in laminar flow in a cylindrical tube10.1016/0021-8502(71)90015-2 ↗
46. Simultaneous diffusion and sedimentation of aerosol particles from Poiseuille flow in a circular tube10.1016/0021-8502(78)90059-9 ↗
47. Simultaneous diffusion and sedimentation of aerosols in channel flows10.1016/0021-8502(75)90059-2 ↗
48. Heat transfer in laminar flow between parallel porous plates10.1016/0017-9310(65)90034-7 ↗
49. Effects of ultrafine and fine particulate and gaseous air pollution on cardiac autonomic control in subjects with coronary artery disease: The ULTRA study10.1038/sj.jea.7500460 ↗
50. Exact solution for flow in a porous pipe with unsteady wall suction and/or injection10.1016/j.cnsns.2005.12.009 ↗
51. Measurements of the penetration of monodisperse aerosols through leaky respirator filters10.1016/0021-8502(92)90519-2 ↗
52. Aerosol penetration and leakage characteristics of masks used in the health care industry10.1016/0196-6553(93)90027-2 ↗
53. A model of aerosol penetration through fibrous filters with pinholes
54. Characterizing diesel particulate filter failure during commercial fleet use due to pinholes, melting, cracking, and fouling10.1007/s40825-016-0036-0 ↗
55. Laminar pipe flow with injection and suction through a porous wall
56. Fractionation of trace elements and human health risk of submicron particulate matter (PM1) collected in the surroundings of coking plants10.1007/s10661-017-6117-x ↗
57. Analytical model of the transport of aerosol particles in a circular hole inside a porous medium10.1007/s11242-014-0429-x ↗
58. Pressure-driven flow in a two-dimensional channel with porous walls10.1017/S0022112009005837 ↗