journal article·2016-02

Addition of molybdenum into amorphous glass‐coated microwires usable as temperature sensors in biomedical applications

Radovan Hudak, Rastislav Varga, Irenej Polacek, Peter Klein, Ivan Skorvanek, Vladimir Komanicky, Rafael P. del. Real, Manuel Vazquez

physica status solidi (a)· Volume 213· Issue 2
Publisher page

Abstract

Compared to other sensors, such as radio‐frequency identification sensors, microwires have a significant advantage due to their small dimensions and contact‐free reading. The most important advantage is that a microwire is considered to be a biocompatible material due to the glass‐coating insulator. This is particularly applicable in various titanium implants (dental, knee joint, replacement of damaged skull part, repair of the femur, etc.). The temperature dependence of the switching field can be employed to monitor inflammatory processes. In this contribution we present the influence of molybdenum (Mo) content on the magnetic properties and thermal treatment in order to obtain a strong variation of the switching field to temperature. We show that stress annealing of a FeMo9BCu microwire at 775 K under an applied axial stress of 309 MPa leads to the strongest variation in a temperature range from 300 to 315 K, which is highly desirable for biomedical applications.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Metallic Glasses and Amorphous Alloys · Magnetic Properties of Alloys · Shape Memory Alloy Transformations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Biomedical Engineering and Measurement Faculty of Mechanical Engineering Technical University of Kosice 04200 Kosice Slovakia

Department of Condensed Matter Physics, Faculty of Science, Institute of Physics P. J. Safarik University Park Angelinum 9 04154 Kosice Slovakia

Slovak Academy of Sciences, Institute of Experimental Physics 04001 Kosice Slovakia

Faculty of Science, Center of Low Temperature Physics University of Pavol Jozef Safarik Park Angelinum 9 04154 Kosice Slovakia

Instituto de Ciencia de Materiales de Madrid, Institute of the Consejo Superior de Investigaciones Cientificas 28049 Madrid Spain

Funding

Diagnostic Methods in Invasive Implantology · NanoCEXmat ITMS · Slovak VEGA

References (21)

Show source-provided references
1. 10.1016/B978-0-08-100164-6.00017-510.1016/B978-0-08-100164-6.00017-5 ↗
2. 10.1016/B978-0-08-100164-6.00008-410.1016/B978-0-08-100164-6.00008-4 ↗
3. 10.1002/pssa.20102641410.1002/pssa.201026414 ↗
4. 10.1063/1.486254010.1063/1.4862540 ↗
5. 10.1063/1.218744310.1063/1.2187443 ↗
6. 10.1063/1.199903610.1063/1.1999036 ↗
7. 10.1016/j.jallcom.2013.12.16510.1016/j.jallcom.2013.12.165 ↗
8. 10.1016/j.msea.2003.10.20010.1016/j.msea.2003.10.200 ↗
9. 10.1016/j.jnoncrysol.2003.08.02510.1016/j.jnoncrysol.2003.08.025 ↗
10. 10.1109/TMAG.2008.200219410.1109/TMAG.2008.2002194 ↗
11. 10.1016/j.jmmm.2011.07.02710.1016/j.jmmm.2011.07.027 ↗
12. 10.1109/TMAG.2014.232348310.1109/TMAG.2014.2323483 ↗
13. 10.1109/TMAG.2012.221985410.1109/TMAG.2012.2219854 ↗
14. 10.1063/1.477673010.1063/1.4776730 ↗
15. 10.3390/s9110921610.3390/s91109216 ↗
16. 10.1109/TMAG.2005.85489910.1109/TMAG.2005.854899 ↗
17. 10.1002/pssa.20143104510.1002/pssa.201431045 ↗
18. 10.1016/j.jallcom.2014.01.09510.1016/j.jallcom.2014.01.095 ↗
19. 10.1103/PhysRevB.72.17442410.1103/PhysRevB.72.174424 ↗
20. Oshida Y. · 2012 · 15
21. 10.1371/journal.pone.004348910.1371/journal.pone.0043489 ↗