Frequency behaviour of light‐addressable potentiometric sensors
Source abstract
Abstract
Abstract Light‐addressable potentiometric sensors (LAPS) are semiconductor‐based potentiometric sensors, with the advantage to detect the concentration of a chemical species in a liquid solution above the sensor surface in a spatially resolved manner. The addressing is achieved by a modulated and focused light source illuminating the semiconductor and generating a concentration‐depending photocurrent. This work introduces a LAPS set‐up that is able to monitor the electrical impedance in addition to the photocurrent. The impedance spectra of a LAPS structure, with and without illumination, as well as the frequency behaviour of the LAPS measurement are investigated. The measurements are supported by electrical equivalent circuits to explain the impedance and the LAPS‐frequency behaviour. The work investigates the influence of different parameters on the frequency behaviour of the LAPS. Furthermore, the phase shift of the photocurrent, the influence of the surface potential as well as the changes of the sensor impedance will be discussed.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical Analysis and Applications · Electrochemical sensors and biosensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Nano‐ and Biotechnologies Aachen University of Applied Sciences Heinrich‐Mußmann‐Straße 1 52428 Jülich Germany
Peter Grünberg Institute (PGI‐8) Research Centre Jülich 52425 Jülich Germany
Department of Biomedical Engineering Tohoku University 6‐6‐05 Aza Aoba, Aramaki, Aoba‐ku, Sendai Miyagi 980‐8579 Japan
Institute of Pharmaceutical Chemistry Philipps University Marburg Marbacher Weg 6–10 35032 Marburg Germany
References (26)
Show source-provided references
1. 10.1126/science.337581010.1126/science.3375810 ↗
2. 10.1146/annurev.bb.23.060194.00051110.1146/annurev.bb.23.060194.000511 ↗
3. 10.1016/0925-4005(93)01199-E10.1016/0925-4005(93)01199-E ↗
4. 10.1016/S0925-4005(96)01903-X10.1016/S0925-4005(96)01903-X ↗
5. 10.1016/S0013-4686(01)00564-310.1016/S0013-4686(01)00564-3 ↗
6. 10.1016/j.ymeth.2005.05.02010.1016/j.ymeth.2005.05.020 ↗
7. 10.1016/S0925-4005(02)00056-410.1016/S0925-4005(02)00056-4 ↗
8. 10.1016/S0925-4005(03)00437-410.1016/S0925-4005(03)00437-4 ↗
9. 10.1016/j.electacta.2007.04.00610.1016/j.electacta.2007.04.006 ↗
10. 10.1021/ac902407610.1021/ac9024076 ↗
11. 10.1126/science.279938410.1126/science.2799384 ↗
12. 10.1016/0956-5663(92)87004-910.1016/0956-5663(92)87004-9 ↗
13. 10.1016/S0956-5663(02)00109-410.1016/S0956-5663(02)00109-4 ↗
14. 10.1016/j.semcdb.2009.01.01410.1016/j.semcdb.2009.01.014 ↗
15. 10.1016/j.bios.2008.08.04510.1016/j.bios.2008.08.045 ↗
16. 10.1002/pssa.20100114110.1002/pssa.201001141 ↗
17. 10.1002/pssa.20110080110.1002/pssa.201100801 ↗
18. 10.1016/j.proche.2009.07.37110.1016/j.proche.2009.07.371 ↗
19. 10.1016/j.snb.2009.12.02210.1016/j.snb.2009.12.022 ↗
20. 10.1016/j.snb.2010.01.00410.1016/j.snb.2010.01.004 ↗
21. 10.1016/S0925-4005(00)00696-110.1016/S0925-4005(00)00696-1 ↗
22. 10.1063/1.35602210.1063/1.356022 ↗
23. 10.1016/S0925-4005(97)00233-510.1016/S0925-4005(97)00233-5 ↗
24. 10.1016/0925-4005(92)80348-210.1016/0925-4005(92)80348-2 ↗
25. A.PoghossianandM. J.Schöning Encyclopedia of Sensors (American Scientific Publishers Santa Clarita California USA 2006) chap. Silicon‐based chemical and biological field‐effect sensors pp. 1–71.
26. 10.1016/j.electacta.2011.03.01210.1016/j.electacta.2011.03.012 ↗