journal article·2018-04

Application of a Plasmonic Biosensor for Detection of Human-Liver Tissues

V. A. Popescu

Plasmonics· Volume 13· Issue 2
Publisher page

Abstract

A recently published plasmonic biosensor based on birefringent solid-core microstructured optical fiber is applied for detection of five types of human-liver tissues (normal N, metastatic MET, non-cancerous metastatic (NMET), hepatocellular carcinoma (HCC), and non-cancerous hepatocellular carcinoma (NHCC)). The birefringent behavior is obtained by removing five central air holes of a two-ring hexagonal lattice of holes in a gold covered silica fiber with the liver layer surrounding the fiber. The loss spectra show two resonant peaks corresponding to the phase matching points. To distinguish between normal and malignant liver tissues, we compare the relevant parameter for the type I and II core modes. Thus, for a decrease of the real part of the refractive index from 1.373431 (human-liver N) to 1.354602 (human-liver MET), the resonance spectral width δλ 0.5 is increased from 44.3 to 54.2 nm for the core mode II. In addition, the amplitude sensitivity S A is decreased from 158.6 to 88.4 RIU−1 for the same core mode. The advantages of another recently proposed plasmonic sensor based on a Bragg fiber are the larger values of the transmission loss, maximum value of the amplitude sensitivity, figure of merit, power fraction in a normal liver layer, and power fraction in the gold layer as compared with that for a microstructured fiber when applied for detection of a normal liver tissue. Another advantage of the Bragg fiber is related to the smaller value of the difference between maximal amplitude sensitivity and resonant wavelengths.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Biosensing Techniques and Applications · Advanced biosensing and bioanalysis techniques · Monoclonal and Polyclonal Antibodies Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Giannios P, Toutouzas KG, Matiatou M, Stasinos K, Konstadoulakis MM, Zografos GC, Moutzouris K (2016) Visible to near-infrared refractive properties of freshly-excised human-liver tissues: marking hepatic malignancies. Sci Rep 6:27910. doi: 10.1038/srep2791010.1038/srep27910 ↗
2. Wang Y, Luo Z, Liu K, Wang J, Duan Y (2016) In situ targeting TEM8 via immune response and polypeptide recognition by wavelengthmodulated surface plasmon resonance biosensor. Sci Rep 6:20006. doi: 10.1038/srep2000610.1038/srep20006 ↗
3. Popescu VA, Puscas NN, Perrone G (2012) Power absorption efficiency of a new microstructured plasmon optical fiber. J Opt Soc Am B 29(11):3039–3046. doi: 10.1364/JOSAB.29.00303910.1364/JOSAB.29.003039 ↗
4. Popescu VA, Puscas NN, Perrone G (2014) Strong power absorption in a new microstructured holey fiber-based plasmonic sensor. J. Opt. Soc. Am. B 31(5):1062–1070. doi: 10.1364/JOSAB.31.00106210.1364/JOSAB.31.001062 ↗
5. Popescu VA, Puscas NN, Perrone G (2016) Simulation of the sensing performance of a plasmonic biosensor based on birefringent solid-core microstructured optical fiber. Plasmonics . doi: 10.1007/s11468-016-0342-y Published online: 08 August 201610.1007/s11468-016-0342-y ↗
6. Popescu VA (2016) Application of a plasmonic biosensor for detection of human blood groups. Plasmonics 10.1007/s11468-016-0440-xPublished online: 22 November 2016
7. Popescu VA, Puscas NN, Perrone G (2016) Sensing performance of the Bragg fiber-based plasmonic sensors with four layers. Plasmonics 11(4):1183–1189. doi: 10.1007/s11468-015-0158-110.1007/s11468-015-0158-1 ↗
8. Sharma AK, Rajan R, Gupta BD (2007) Influence of dopants on the performance of a fiber optic surface plasmon resonance sensor. Opt Commun 274(2):320–32610.1016/j.optcom.2007.02.030 ↗
9. Verma RK, Sharma AK, Gupta BD (2008) Surface plasmon resonance based tapered fiber optic sensor with different taper profiles. Opt Commun 281:1486–149110.1016/j.optcom.2007.11.007 ↗
10. Ghatak AK, Thyagarajan K (1999) Introduction to fiber optics. Cambridge University Press, Cambridge
11. Madarasz FL, Dimmock JO, Dietz N, Bachmann KL (2000) Sellmeier parameters for ZnGaP2 and GaP. J Appl Phys 87(3):1564–1565. doi: 10.1063/1.37205010.1063/1.372050 ↗
12. Vial A, Grimault AS, Macías D, Barchiesi D, Chapelle ML (2005) Improved analytical fit of gold dispersion: Application to the modeling of extinction spectra with a finite-difference time-domain method. Phys Rev B 71:085416. doi: 10.1103/PhysRevB.71.08541610.1103/PhysRevB.71.085416 ↗
13. Shalabney A, Abdulhalim I (2012) Figure-of-merit enhancement of surface plasmon resonance sensors in the spectral interrogation. Opt Lett 37(7):1175–1177. doi: 10.1364/OL.37.00117510.1364/OL.37.001175 ↗
14. Popescu VA, Puscas NN, Perrone G (2016) Application of a new vector mode solver to optical fiber based plasmonic sensors. Mod Phys Lett B 30(7):1650075. doi: 10.1142/S021798491650075510.1142/S0217984916500755 ↗
15. Popescu VA, Puscas NN (2015) Propagation characteristic in a new photonic fiber based plasmonic sensor. Rom Rep Phys 67(2):500–507 http://www.rrp.infim.ro/2015_67_2/A20.pdf
16. Popescu VA, Puscas NN, Perrone G ((2015)) Efficient light absorption in a new Bragg fiber-based plasmonic sensor. J Opt Soc Am B 32(3):473–478 (2015). doi: 10.1364/JOSAB.32.00047310.1364/JOSAB.32.000473 ↗