journal article·2019-07

Improved bone ingrowth of tricalcium phosphate filled Poly(methyl methacrylate) (PMMA) bone cements in vivo

Shan Gao, Yang Lv, Liang Yuan, Huihui Ren, Teng Wu, Bingchuan Liu, Yawen Zhang, Rubing Zhou, Ailing Li, Fang Zhou

Polymer Testing· Volume 76
Publisher page

Abstract

Abstract The cement augmentation technique using poly(methyl methacrylate) (PMMA) is considered to be the most effective method for fixation of osteoporotic fracture because of its outstanding mechanical properties. However, the low bio-degradation of PMMA, which hinders bone ingrowth, limits it potential for a broad range of applications. Previous studies have shown blending β-tricalcium phosphate (β-TCP) with PMMA was able to improve the osteoconduction while the material still suffered poor mechanical properties due to the poor compatibility between two components. In this study, we explored the use of hydroxyethyl methacrylate (HEMA) as a compatibilizer for improving the affinity of TCP/PMMA blends system. The resultant TCP/HEMA/PMMA(THP) composite cements exhibited similar setting properties to PMMA cement but much better mechanical properties than composite systems without HEMA as a compatibilizer. No cytotoxicity or hemolysis was observed in the THP bone cement system by biochemical assays. Bone ingrowth was significantly improved at 12 weeks. The reinforced pull-out strength of screws was observed at 4, 8, 12 weeks through in vivo studies performed on rabbit femurs. The THP system, as an injectable bone cement material, shows great potential for use in the cement augmentation technique.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Bone mechanical properties and changes with osteoporosis10.1016/S0020-1383(16)47003-8 ↗
2. Strontium ranelate treatment enhances hydroxyapatite-coated titanium screws fixation in osteoporotic rats10.1002/jor.21050 ↗
3. The biomechanics of pedicle screw augmentation with cement10.1016/j.spinee.2015.03.016 ↗
4. Single-dose local simvastatin injection improves implant fixation via increased angiogenesis and bone formation in an ovariectomized rat model
5. Biomechanical comparison of sagittal-parallel versus non-parallel pedicle screw placement10.1007/s00701-014-2244-0 ↗
6. Pedicle screw augmentation with bone cement enforced Vicryl mesh10.1002/jor.23631 ↗
7. Pull-out stability of anchors for rotator cuff repair is also increased by bio-absorbable augmentation: a cadaver study10.1007/s00402-016-2484-y ↗
8. A novel injectable calcium phosphate-based nanocomposite for the augmentation of cannulated pedicle-screw fixation10.2147/IJN.S131962 ↗
9. Influence of hydroxyapatite stick on pedicle screw fixation in degenerative lumbar spine: biomechanical and radiologic study10.1097/BSD.0000000000000405 ↗
10. Biomechanical Comparisons of Pull Out Strengths after Pedicle Screw Augmentation with Hydroxyapatite, Calcium Phosphate, or Polymethylmethacrylate in the Cadaveric Spine10.1016/j.wneu.2015.01.056 ↗
11. In vivo study of pedicle screw augmentation using bioactive glass in osteoporosis sheep10.1097/BSD.0b013e31827695e2 ↗
12. Biomechanical Evaluation of a Novel Fenestrated Pedicle Screw Augmented with Bone Cement in Osteoporotic Spines
13. The quantity of bone cement influences the anchorage of augmented pedicle screws in the osteoporotic spine: a biomechanical human cadaveric study10.1016/j.clinbiomech.2017.12.012 ↗
14. Biological activity of an injectable biphasic calcium phosphate/PMMA bone cement for induced osteogensis in rabbit model10.1002/mabi.201700331 ↗
15. Orthopaedic implant failure: aseptic implant loosening–the contribution and future challenges of mouse models in translational research10.1042/CS20130338 ↗
16. Primary hybrid THA using a polymethyl methacrylate-precoated stem: a single-center experience with a 10-year minimum follow-up10.1002/jbm.b.33626 ↗
17. The biocompatibility of porous vs non-porous bone cements: a new methodological approach10.4081/ejh.2014.2255 ↗
18. Preparation of calcium phosphate cement and polymethyl methacrylate for biological composite bone cements
19. Biocompatibility and bone formation with porous modified PMMA in normal and irradiated mandibular tissue10.1111/j.1600-0501.2011.02388.x ↗
20. Effect of modification degree of nanohydroxyapatite on biocompatibility and mechanical property of injectable poly(methyl methacrylate)-based bone cement10.1002/jbm.b.33428 ↗
21. Enhanced osteointegration of poly(methylmethacrylate) bone cements by incorporating strontium-containing borate bioactive glass10.1098/rsif.2016.1057 ↗
22. Amphiphilic bioactive filler for acrylic bone cement to enhance its cell adhesion10.1166/jbn.2018.2543 ↗
23. Influence of nano-HA coated bone collagen to acrylic (polymethylmethacrylate) bone cement on mechanical properties and bioactivity
24. Physicochemical and cell biological characterization of PMMA bone cements modified with additives to increase bioactivity10.1002/jbm.b.32862 ↗
25. Calcium phosphate cements as drug delivery materials10.1016/j.addr.2012.01.008 ↗
26. Biphasic calcium phosphate ceramics for bone reconstruction: a review of biological response10.1016/j.actbio.2017.01.076 ↗
27. Polymethylmethacrylate bone cements and additives: a review of the literature10.5312/wjo.v4.i2.67 ↗
28. Klein · 1990
29. Critical review: injectability of calcium phosphate pastes and cements10.1016/j.actbio.2016.11.019 ↗
30. How smart do biomaterials need to be? A translational science and clinical point of view10.1016/j.addr.2012.07.009 ↗
31. ISO 5833 · 2002
32. ISO10993–5 · 2009
33. In vivo study of a bioactive nanoparticle-gelatin composite scaffold for bone defect repair in rabbits10.1007/s10856-017-5991-7 ↗
34. Tailored surface treatment of 3D printed porous Ti6Al4V by microarc oxidation for enhanced osseointegration via optimized bone in-growth patterns and interlocked bone/implant interface
35. Peri-implant osteogenesis in health and osteoporosis10.1016/j.micron.2005.07.008 ↗
36. A novel injectable bioactive bone cement for spinal surgery: a developmental and preclinical study10.1002/1097-4636(200010)52:1<164::AID-JBM21>3.0.CO;2-R ↗
37. A randomized clinical trial evaluating rh-FGF-2/β-TCP in periodontal defects10.1177/0022034516632497 ↗
38. Monophasic ß-TCP vs. biphasic HA/ß-TCP in two-stage sinus floor augmentation procedures – a prospective randomized clinical trial10.1111/clr.12983 ↗
39. Effect of surface sealant reapplication on clinical performance of HEMA-containing and HEMA-free self-etch adhesives: two-year results10.2341/17-141-C ↗
40. Bioactive glass in tissue engineering10.1016/j.actbio.2011.03.016 ↗
41. Assessment of human gingival fibroblast interaction with dental implant abutment materials10.1007/s10856-015-5481-8 ↗
42. Cell behaviors on polysaccharide-wrapped single-wall carbon nanotubes: a quantitative study of the surface properties of biomimetic nanofibrous scaffolds10.1021/nn9006362 ↗
43. Influence of carboxymethyl chitin on stability and biocompatibility of 3D nanohydroxyapatite/gelatin/carboxymethyl chitin composite for bone tissue engineering10.1002/jbm.b.31983 ↗
44. Does early micromotion of femoral stem prostheses matter? 4-7-Year stereoradiographic follow-up of 84 cemented postheses
45. Weak effect of strontium on early implant fixation in rat tibia10.1016/j.bone.2011.10.034 ↗
46. A comprehensive study of osteogenic calcium phosphate silicate cement: material characterization and in vitro/in vivo testing10.1002/adhm.201500469 ↗