journal article·2025-09Open access

Skin/core fracture toughness of sandwich structures: a comparison of different experimental arrangements

Amal Alliyankal Vijayakumar, Muhammad Zahid, Stefano G. Corvaglia, Alfonso Maffezzoli

Polymer Testing· Volume 150

Abstract

Thermoplastic sandwich structures are most prominently used due to their intrinsic strength-to-weight ratio, recyclability, damping capabilities, and ease of processing. Nonetheless, skin/core debonding is a critical failure mode, limiting the stress transfer between the skin and core. This research adopts a cost-effective thermoforming approach for simultaneous commingled E-glass/Polypropylene (PP) fabric consolidation and closed-cell PP foam core bonding via a one-stage non-isothermal process. Several test methods have been developed to optimise and evaluate the interfacial bonding, analysing Mode I fracture energy. This study introduces a novel comparative evaluation of different variants of single cantilever beam (SCB) arrangements for measuring the Mode I interfacial fracture toughness of a single polymer (PP) sandwich structure, adopting a fixed and a horizontal sliding constraint for the sandwich panel. A rigid base with a flexible rod for load application was also used. Additionally, the study analyses the effects of skin thickness on testing arrangements and fracture toughness. The SCB with a sliding constraint is considered the most suitable configuration for measuring the Mode I-dominant fracture toughness of sandwich structures with varying skin thicknesses. However, the flexible long-loading rod and roller base configurations yield similar fracture toughness values for sandwich structures with thicker skins. The predominant mix Mode crack propagation at the crack tip limited the applicability of SCB with a rigid base in evaluating the pure Mode I. The skin thickness significantly affects the fracture toughness and debonding paths in sandwich structures. Throughout all Mode I arrangements and skin thicknesses, the crack advanced through densified or undeformed foam cells, indicating skin/core fusion bonding via the one-stage process.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Mechanical Behavior of Composites · Structural Analysis of Composite Materials · Material Properties and Processing

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. 7 - thermoset resin sandwich structures
2. A review of mode I dominant interfacial fracture toughness test methods of skin-core bonding for thermoplastic composite sandwich structures10.1177/08927057221083493 ↗
3. Manufacturing of thermoplastic composite sandwich structures: a review of literature10.1177/0892705715604681 ↗
4. All-thermoplastic composite sandwich panels – part I: manufacturing and improvement of surface quality10.1177/1099636204040094 ↗
5. Self-reinforcing and toughening isotactic polypropylene via melt sequential injection molding10.1016/j.polymertesting.2018.03.005 ↗
6. An alternating skin–core structure in melt multi-injection-molded polyethylene10.1002/mame.201700465 ↗
7. Creep and recovery behavior of injection-molded isotactic polypropylene with controllable skin-core structure10.1016/j.polymertesting.2018.05.040 ↗
8. Definition of process parameters for manufacturing of thermoplastic composite sandwiches – part A: modelling10.1177/0892705717729013 ↗
9. Processing-properties relationship of sandwich panels with polypropylene-core and polypropylene-matrix composite skins10.1002/pc.20025 ↗
10. Fracture mechanics analysis of Tilted Sandwich Debond (TSD) specimen10.1177/002199801772661399 ↗
11. The effect of interface debonding on flexural behaviour of composite sandwich beams10.1177/1099636218781981 ↗
12. Using the Climbing Drum Peel (CDP) test to obtain a GIC value for core/face sheet bonds10.1177/0021998307079974 ↗
13. Sizing a single cantilever beam specimen for characterizing facesheet–core debonding in sandwich structure10.1177/0021998311401116 ↗
14. Fracture toughness and crack growth resistance of sandwich panels with grooved cores10.1177/10996362221077053 ↗
15. Investigation of the applicability of single cantilever beam test for the evaluation of fracture toughness of sandwich composites10.1016/j.engfracmech.2023.109075 ↗
16. Adams · 2008
17. The Tilted Sandwich Debond (TSD) specimen for face/core interface fracture characterization10.1177/109963629900100104 ↗
18. Debonding failure of sandwich-composite cryogenic fuel tank with internal core pressure10.2514/1.5567 ↗
19. A test technique for assessing core-skin adhesion in composite sandwich structures10.1007/BF00278162 ↗
20. A study of skin-core adhesion in glass fibre reinforced sandwich materials10.1007/BF00133683 ↗
21. Experimental investigation of compression moulding of glass/PA12-PMI foam core sandwich components10.1016/S1359-835X(99)00028-7 ↗
22. Characterizing facesheet/core disbonding in honeycomb core sandwich structure
23. Influence of geometry, elasticity properties and boundary conditions on the mode I purity in sandwich composites10.1016/j.compstruct.2019.110942 ↗
24. 2021
25. Mode I interlaminar fracture toughness of woven glass/epoxy composites with mat layers at delamination interface10.1016/j.polymertesting.2019.105943 ↗
26. Post-curing effect on the mode I fracture toughness of the glass/epoxy laminates10.1002/pc.29378 ↗
27. An augmented double cantilever beam model for studying crack propagation and arrest10.1007/BF00035958 ↗
28. Elastic foundation analysis of Tilted Sandwich Debond (TSD) specimen10.1177/109963620000200101 ↗
29. Mixed mode cracking in layered materials
30. Crack kinking of a delamination at an inclined core junction interface in a sandwich beam10.1016/j.engfracmech.2008.06.034 ↗
31. Mode mixity analysis of face/core debonds in a single cantilever beam sandwich specimen10.1177/1099636218788223 ↗
32. On the analysis of mixed-mode failure10.1007/BF00035361 ↗
33. Carlsson · 2011 · 121
34. Crack length correction and root rotation angle in a sandwich single cantilever beam (SCB) fracture specimen
35. 2021