journal article·2018-04

Cyclic loading of model silicone elastomer samples with regard to the failure of silicone breast implants

Dirk W. Schubert, Michael Lämmlein, Harald von Hanstein

Polymer Testing· Volume 66
Publisher page

Abstract

Abstract It is estimated that 15.000 to 20.000 breast augmentations are performed annually in Germany and several million worldwide. To obtain better knowledge of the reason for and the time of a possible failure of the implant shell, it is important to acquire information regarding the stability and durability of the material used and the associated failure criteria. The mechanical properties of silicone elastomers have, therefore, been investigated with regard to breast implants. Sample strips of the elastomer of various thicknesses were prepared and exposed to a cyclic bending load for a number of load cycles. Tensile specimens were punched out according to a defined pattern from the preloaded sample strips and tested with regard to their tensile properties, particularly the influence of cyclic loading on the stress at break. However, as quality of a silicone implant depends, not only on the strength of the material, but also on the spatial variation in the mechanical properties the quality of the silicone samples was also assessed in terms of the characteristic stress at break and the Weibull modulus, applying Weibull statistics to the tensile test results. The study revealed that the characteristic stress at break remained constant with increasing number of load cycles, but that the Weibull modulus decreased exponentially during the first 10.000 cycles to a critical level.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Breast Implant and Reconstruction · Automotive and Human Injury Biomechanics · biodegradable polymer synthesis and properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (12)

Show source-provided references
1. Analysis of explanted silicone implants: a report of 300 patients10.1097/00000637-199501000-00001 ↗
2. Rupture and aging of silicone gel breast implants10.1097/00006534-199304001-00012 ↗
3. Silicone gel breast implant failure: evaluation of properties of shells and gels for explanted prostheses and meta-analysis of literature rupture data10.1097/00000637-200209000-00001 ↗
4. The nature of the collagenous capsules around breast implants10.1097/00006534-197910000-00004 ↗
5. Liquid- and solid-state high-resolution NMR methods for the investigation of aging processes of silicone breast implants10.1016/S0142-9612(02)00241-7 ↗
6. Ultimate strength properties of control and explanted Silastic 0 and Silastic I silicone gel-filled breast implant shells10.1053/aq.1999.v19.101951001 ↗
7. Ultimate strength properties of explanted and control Silastic II silicone gel-filled breast implant shells10.1067/maj.2000.106399 ↗
8. In vivo aging characteristics of silicone gel breast implants compared to lot-matched controls10.1097/00006534-200205000-00024 ↗
9. Aging of retrieved gel breast implants: a comparison between two product generations10.1016/j.jmbbm.2015.02.008 ↗
10. A. G. Wacker Chemie, Technical Data Sheet of Elastosil® LR 3003/30.
11. On the failure of silicone breast implants: new insights by mapping the mechanical properties of implant shells10.1002/pi.4619 ↗
12. 2013