Development and improvement of a transient temperature model of PV modules: Concept of trailing data
Source abstract
Abstract
Abstract The development of a transient temperature model of photovoltaic (PV) modules is presented in this paper. Currently, there are a few steady‐state temperature models targeted at assessing and predicting the PV module temperature. One of the most commonly used models is the Faiman thermal model. This model is derived from the modified Hottel‐Whillier‐Bliss (HWB) model for flat‐plate solar‐thermal collector under steady‐state conditions and assumes low or no thermal mass in the modules (i.e., short time constants such that transients are neglected, and steady‐state conditions are assumed). The transient extension of the Faiman model we present in this paper introduces a thermal mass, which provides two advantages. First of all, it improves the temperature prediction under dynamic conditions. Second, our transient extension to the Faiman model allows the accurate parametrization of the Faiman model under dynamic conditions. We present our model and parametrization method. Furthermore, we applied the model and parametrization method to a 1‐year data set with 5‐min resolved outdoor module measurements. We demonstrate a significant improvement in temperature prediction for the transient model, especially under dynamic conditions.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Photovoltaic System Optimization Techniques · Solar Thermal and Photovoltaic Systems · Solar Radiation and Photovoltaics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
IEK‐5 Photovoltaik, Forschungszentrum Jülich GmbH Jülich Germany
Department of Physics and Astronomy University of Nigeria Nsukka Enugu Nigeria
Jülich Aachen Research Alliance (JARA‐Energy) and Faculty of Electrical Engineering and Information Technology RWTH Aachen University Aachen Germany
Funding
Bundesministerium für Bildung und Forschung
References (31)
Show source-provided references
1. 10.1016/j.solener.2008.10.00810.1016/j.solener.2008.10.008 ↗
2. 10.1016/j.solener.2012.11.00110.1016/j.solener.2012.11.001 ↗
3. 10.1016/j.energy.2014.04.11510.1016/j.energy.2014.04.115 ↗
4. 10.1016/j.solener.2017.03.00210.1016/j.solener.2017.03.002 ↗
5. 10.1049/iet‐rpg.2016.068210.1049/iet‐rpg.2016.0682 ↗
6. LiaoW HeoY XuS.Evaluation of temperature dependent models for PV yield prediction in Proceedings of the 4th Building Simulation and Optimization Conference Cambridge UK 2018;11–12.
7. DriesseA TheristisM SteinJS.PV module operating temperature model equivalence and parameter translation in 49th Photovoltaic Specialist Conference (PVSC) Philadelphia PA USA 2022.10.1109/PVSC48317.2022.9938895 ↗
8. 10.1016/j.egypro.2013.08.01010.1016/j.egypro.2013.08.010 ↗
9. An analytical model for estimating the temperature of a photovoltaic module based on the principle of energy balance
10. 10.1016/j.egypro.2014.12.43310.1016/j.egypro.2014.12.433 ↗
11. 10.1016/S0038‐092X(00)00149‐310.1016/S0038‐092X(00)00149‐3 ↗
12. Luketa‐HanlinA SteinJ.Improvement and validation of a transient model to predict photovoltaic module temperature Sandia National Laboratories (SNL) Albuquerque NM and Livermore CA 2012.
13. 10.1088/1742-6596/1101/1/01200910.1088/1742-6596/1101/1/012009 ↗
14. 10.1016/j.renene.2008.04.00910.1016/j.renene.2008.04.009 ↗
15. IEC.IEC 61853‐3 Ed. 1.0: Photovoltaic (PV) module performance testing and energy rating—part 3: energy rating of PV modules 2018;6–13.
16. HerrmannW MonokroussosC LeeK.Comparison of different approaches to determine the nominal PV module operating temperature (NMOT) in Paper presented at 38th European Photovoltaic Solar Energy Conference and Exhibition 2021;6:10.
17. 10.1016/j.solmat.2011.01.02010.1016/j.solmat.2011.01.020 ↗
18. 10.1002/pip.277310.1002/pip.2773 ↗
19. KratochvilJA BoysonWE KingDL.Photovoltaic array performance model Sandia National Laboratories (SNL) Albuquerque NM and Livermore CA 2004.
20. 10.1016/j.solener.2013.03.02810.1016/j.solener.2013.03.028 ↗
21. 10.5755/j01.eie.25.2.2320310.5755/j01.eie.25.2.23203 ↗
22. 10.1016/j.renene.2005.03.01010.1016/j.renene.2005.03.010 ↗
23. 10.1016/j.applthermaleng.2010.03.01210.1016/j.applthermaleng.2010.03.012 ↗
24. 10.1016/j.applthermaleng.2005.02.00810.1016/j.applthermaleng.2005.02.008 ↗
25. 10.1016/j.renene.2009.02.02710.1016/j.renene.2009.02.027 ↗
26. OhSY KimMS SoWS et al.Outdoor operating temperature modeling of photovoltaic modules including transient effect in 2017 IEEE 44th Photovoltaic Specialist Conference (PVSC) 25–30.2017;487–489 doi:10.1109/PVSC.2017.8366327.10.1109/PVSC.2017.8366327 ↗
27. 10.1002/pip.81310.1002/pip.813 ↗
28. IEC.IEC 61853‐2 Ed. 1.0: Photovoltaic (PV) module performance testing and energy rating—part 2: spectral responsivity incidence angle and module operating temperature measurements.2016;17–19.
29. FrostJ.7 Classical assumptions of ordinary least squares (ols) linear regression. Statistics By Jim.https://statisticsbyjim.com/regression/ols-linear-regression-assumptions/(accessed September 27 2023).
30. FrostJ.Heteroscedasticity in regression analysis. Statistics by Jim.https://statisticsbyjim.com/regression/heteroscedasticity-regression/(accessed September 27 2023).
31. Frost J · 2020