journal article·2011-06

On the characterisation of PV inverters' efficiency—introduction to the concept of achievable efficiency

B. Bletterie, R. Bründlinger, G. Lauss

Publisher page

Abstract

Abstract The availability of accurate performance figures for photovoltaic (PV) inverters is of prime importance when it comes to the selection of products, the design of installations or the estimation of the annual yield. This paper proposes an improvement of the current practise by introducing a new quantity to quantify the performance of inverters: the maximal achievable European efficiency. This quantity can be based on the distribution of the annual yield as a function of maximum power point (MPP) power and voltage or on the existing weighting factors of the European efficiency. In a first step, the concept of the required MPP voltage window is introduced on the basis of a detailed analysis of the operating conditions for a typical location in Central Europe. It quantifies the voltage window in which the inverter shall operate and in which the average efficiency shall be calculated. In a second step, a method to process the efficiency measurements as they are now commonly performed is described. By combining the detailed characterisation of the inverter efficiency and the distribution of the annual irradiation as function of the operating conditions, an average and a maximal efficiency over the whole inverter specified MPP voltage range are obtained. They provide a very valuable information about the overall performance of the inverter and about its sensitivity to the plant configuration. As a good compromise between simplicity and accuracy, the proposed concept of achievable European efficiency should be preferred to the current practises. Copyright © 2010 John Wiley & Sons, Ltd.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photovoltaic System Optimization Techniques · Solar Thermal and Photovoltaic Systems · solar cell performance optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. BaumgartnerF.Euro Realo inverter efficiency: DC‐voltage dependency Proceedings of 20th European Photovoltaic Solar Energy Conference and Exhibition Barcelona Spain 2005.
2. Hotopp R · 1991
3. HäberlinH BorgnaL KämpferM ZwahlenU.Total efficiencyη‐tot—a new quantity for better characterisation of grid‐connected PV inverters Proceedings of 20th European Photovoltaic Solar Energy Conference and Exhibition Barcelona Spain June 2005.
4. BründlingerR BletterieB BrandJ.A new method for the assessment of the dynamic MPP tracking performance based on compressed high‐resolution irradiation patterns Proceedings of 20th European Photovoltaic Solar Energy Conference and Exhibition Barcelona Spain June 2005.
5. BletterieB BründlingerR SpielauerS.Quantifying dynamic MPPT performance under realistic conditions first test results—the way forward Proceedings of 21st European Photovoltaic Solar Energy Conference and Exhibition Dresden Germany September 2006.
6. HäberlinH SchärfP.New procedure for measuring dynamic MPP‐tracking efficiency at grid‐connected PV inverters.Proceedings of 24th European Photovoltaic Solar Energy Conference and Exhibition Hamburg Germany September2009;3631–3637. DOI:10.4229/24thEUPVSEC2009‐4BV.1.9
7. 10.1002/pip.76310.1002/pip.763 ↗
8. BründlingerR BletterieB MildeM OldenkampH.Maximum power point tracking performance under partially shaded PV array conditions Proceedings of 21st European Photovoltaic Solar Energy Conference and Exhibition Dresden Germany September 2006.
9. FprEN 50530:2008: Overall efficiency of photovoltaic inverters.
10. BründlingerR HenzeN HäberlinH BurgerB BergmannA BaumgartnerF. prEN 50530—the new European standard for performance characterisation of PV inverters.Proceedings of 24th European Photovoltaic Solar Energy Conference Hamburg Germany September2009;3105–3109. DOI:10.4229/24thEUPVSEC2009‐4EP.1.2
11. 10.1109/TPEL.2005.85097510.1109/TPEL.2005.850975 ↗
12. 10.1002/pip.45910.1002/pip.459 ↗
13. BettenwortG GrooteW JuchemR KühnelC LaschinskiJ LeonhardtG.PV inverter integrated active shadow tracking guarantees maximum energy yield.Proceedings of 23rd European Photovoltaic Solar Energy Conference and Exhibition Valencia Spain September2009;2777–2780. DOI:10.4229/23rdEUPVSEC2008‐4DO.9.2
14. RansomeS FuntanP.Why hourly averaged measurement data is insufficient to model PV system performance accurately Proceedings of 20th European Photovoltaic Solar Energy Conference and Exhibition Barcelona Spain June 2005.
15. BletterieB BründlingerR HäberlinH BaumgartnerF SchmidtH BurgerB KleinG Alonso AbellaM.Redefinition of the European efficiency—finding the compromise between simplicity and accuracy.Proceedings of 23rd European Photovoltaic Solar Energy Conference and Exhibition Valencia Spain September2008;2735–2742. DOI:10.4229/23rdEUPVSEC2008‐4CO.2.5
16. BletterieB BründlingerR ZdanowiczT KolodennyW BettenwortG.I–VCurve modelling for inverter testing—a critical review of current approaches Proceedings of 22nd European Photovoltaic Solar Energy Conference and Exhibition ▽ Milano Italy September 2007.
17. BaumgartnerF SchmidtH BurgerB BründlingerR HäberlinH ZehnerM.Status and relevance of the DC voltage dependency of the inverter efficiency Proceedings of 22nd European Photovoltaic Solar Energy Conference and Exhibition Milano Italy September 2007.
18. BaumgartnerF ScholzH BreuA RothS.MPP voltage monitoring to optimise grid connected system design rules Proceedings 19th European Photovoltaic Solar Energy Conference and Exhibition Paris France June 2004.
19. Euro‐Realo efficiency data sheet Photon magazine June2004;65.
20. HäberlinH.Optimum DC operating voltage for grid‐connected PV plants. Choice of VMPP for measurements of efficiency and VMPP‐STC at PV plants for grid‐connected inverters with a wide DC input voltage range Proceedings of 20th European Photovoltaic Solar Energy Conference and Exhibition Barcelona Spain June 2005.
21. HäberlinH.Photovoltaik Strom aus Sonnenlicht für Verbundnetz und Inselanlagen VDE Verlag Berlin 2007 ISBN 978‐3‐8007‐3003‐2.
22. BurgerB SchmidtH GoeldiB BletterieB BründlingerR HäberlinH BaumgartnerF KleinG.Are we benchmarking inverters on the basis of outdated definitions of the European and CEC efficiency?Proceedings of 24th European Photovoltaic Solar Energy Conference and Exhibition Hamburg Germany September2009;3638–3643. DOI:10.4229/24thEUPVSEC2009‐4BV.1.10