journal article·2021-07

Light‐ and elevated temperature‐induced degradation impact on bifacial modules using accelerated aging tests, electroluminescence, and photovoltaic plant modeling

Julien Dupuis, Gilles Plessis, Gilbert El Hajje, Eric Lajoie‐Mazenc, Eric Sandré, Khalid Radouane, Patrick Dupeyrat

Publisher page

Abstract

Abstract The authors report on the light‐ and elevated temperature‐induced degradation (LeTID) effect observed on bifacial photovoltaic modules and its potential impact on photovoltaic plants performance. Indoor LeTID quantification using indoor carrier‐induced degradation (CID) is carried out using current injection. Power measurements yielded higher LeTID sensitivity for the rear side of bifacial modules compared to the front side, hence leading to a variation of the bifaciality factor by several percentage points. The difficulty in evaluating the maximal power degradation caused by LeTID is also highlighted as a reduced number of samples are used most of the time and as cells within a single module do not have always the same performance evolution trends. Using indoor CID results with the help of empirical fitting and Arrhenius relation, the yield impact of LeTID on a bifacial power plant is simulated under three different climates. Modeling results help to identify the main parameters related to LeTID modules sensitivity that impact photovoltaic (PV) plants yield: maximal power degradation, stabilized power value after regeneration, activation energy value, and LeTID kinetics. In some cases, the yield variation caused by LeTID sensitive modules could be mitigated by carefully selecting the modules as a function of climatic conditions.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Silicon and Solar Cell Technologies · Photovoltaic System Optimization Techniques · Semiconductor materials and devices

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

EDF R&D EDF Lab Les Renardières Moret Loing et Orvanne 77250 France

EDF Renouvelables 100, esplanade du Général de Gaulle, Cœur Défense ‐ Tour B Paris La Défense Cedex 92932 France

References (25)

Show source-provided references
1. FokuhlE NaeemT SchmidA GebhardtP GeipelT PhilippD.LeTID—a comparison of test methods on module level Proceedings of the 36th European photovoltaic solar energy conference Marseille France;2019:816‐821.
2. PanderM TurekM BauerJ LukaT HagenforfC.Benchmarking light and elevated temperature induced degradation (LeTID) Proceedings of the 35th European photovoltaic solar energy conference Brussels Belgium;2018:1265‐1268.
3. 10.1016/j.solmat.2015.06.01510.1016/j.solmat.2015.06.015 ↗
4. 10.1016/j.egypro.2017.09.26010.1016/j.egypro.2017.09.260 ↗
5. 10.1109/JPHOTOV.2019.293722310.1109/JPHOTOV.2019.2937223 ↗
6. 10.1002/pip.295410.1002/pip.2954 ↗
7. 10.1063/1.504932010.1063/1.5049320 ↗
8. 10.1063/1.504175610.1063/1.5041756 ↗
9. 10.1016/j.solmat.2019.10993810.1016/j.solmat.2019.109938 ↗
10. 10.7567/JJAP.56.08MB1310.7567/JJAP.56.08MB13 ↗
11. 10.1016/j.egypro.2017.09.30810.1016/j.egypro.2017.09.308 ↗
12. Libal J · 2018 · 328
13. PanderM LukaT JaeckelB et al.Prediction of potential power/yield loss from LeTID susceptible modules Proceedings of the 36th European photovoltaic solar energy conference Marseille France;2019:810‐815.
14. 10.1002/solr.20170015910.1002/solr.201700159 ↗
15. 10.5194/hess-11-1633-200710.5194/hess-11-1633-2007 ↗
16. LindsayA ChiodettiM DupeyratP BinestiD LutunE RadouaneK.Key elements in the design of bifacial PV power plants Proceedings of the 31st European photovoltaic solar energy conference Hamburg Germany;2015:1764‐1769.
17. LindsayA ChiodettiM BinestiD et al.Modelling of single‐axis tracking gain for bifacial PV systems proceedings of the 32ndEuropean photovoltaic solar energy conference Munich Germany;2016:1610‐1617.
18. ChiodettiM LindsayA DupeyratP BinestiD LutunE RadouaneK MouselS.PV bifacial yield simulation with a variable albedo model Proceedings of the 32ndEuropean photovoltaic solar energy conference Munich Germany;2016:1449‐1455.
19. ChiodettiM KangJ ReiseC LindsayA.Predicting yields of bifacial PV power plants—what accuracy is possible?Proceedings of the 35th EUPVSEC. Brussels Belgium;2018:1623‐1629.
20. Duffie JA · 2006
21. 10.1002/047001400810.1002/0470014008 ↗
22. 10.1016/S0038-092X(00)00149-310.1016/S0038-092X(00)00149-3 ↗
23. 10.1016/S0927-0248(00)00408-610.1016/S0927-0248(00)00408-6 ↗
24. 10.1115/1.324445110.1115/1.3244451 ↗
25. El HajjeG DupuisJ DupeyratP.Quantitative mapping of PV modules performance using electroluminescence based imaging Proceedings of the 36th European photovoltaic solar energy conference Marseille France;2019:849‐853.