Development of a novel system for measuring femoroacetabular contact forces in hip arthroscopy

Sérgio B Gonçalves, Pedro Dantas, Francisco Guedes de Melo, João Gouveia, José Guimarães Consciência, Jorge Martins, Miguel Tavares da Silva

Rapid Prototyping Journal· Volume 31· Issue 1
Publisher page

Abstract

Purpose Arthroscopic osteochondroplasty is a minimally invasive procedure that has been used to treat femoroacetabular impingement syndrome, leading to significant improvements in patients’ clinical outcomes and quality of life. However, some studies suggest that inadequate bone resection can substantially alter hip biomechanics. These modifications may generate different contact profiles and higher contact forces, increasing the risk of developing premature joint degeneration. To improve control over bone resection and biomechanical outcomes during arthroscopic osteochondroplasty surgery, this study aims to present a novel system for measuring femoroacetabular contact forces. Design/methodology/approach Following a structured design process for the development of medical devices, the steps required for its production using additive manufacturing with material extrusion and easily accessible sensors are described. The system comprises two main devices, one for measuring femoroacetabular contact forces and the other for quantifying the force applied by the assistant surgeon during lower limb manipulation. The hip device was designed for use within an arthroscopic environment, eliminating the need for additional portals. Findings To evaluate its performance, the system was first tested in a laboratory setup and later under in-service conditions. The 3D printing parameters were tuned to ensure the watertighness of the device and sustain the intraoperative fluid pressures. The final prototype allowed for the controlled measurement of the hip contact forces in real-time. Originality/value Using additive manufacturing and readily available sensors, the present work presents the first device to quantify joint contact forces during arthroscopic surgeries, serving as an additional tool to support the surgeon’s decision-making process regarding bone resection.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Hip disorders and treatments · Orthopaedic implants and arthroplasty · Shoulder Injury and Treatment

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. A review on exploration of the mechanical characteristics of 3D-printed biocomposites fabricated by fused deposition modelling (FDM)10.1108/RPJ-04-2023-0150 ↗
2. Hip morphology influences the pattern of damage to the acetabular cartilage. Femoroacetabular impingement as a cause of early osteoarthritis of the hip10.1302/0301-620X.87B7.15203 ↗
3. Effects of acetabular rim trimming on hip joint contact pressures: how much is too much?10.1177/0363546515590400 ↗
4. Fused deposition modelling: current status, methodology, applications and future prospects10.1016/J.ADDMA.2021.102378 ↗
5. The European medical device regulation 2017/745/EU: changes and impact on stakeholders
6. Additive manufacturing of medical instruments: a state-of-the-art review10.1016/J.ADDMA.2019.03.015 ↗
7. Daniel Proaño Guevara (2023), “Exoskeleton comfort evaluation through smart sensing”, Instituto Superior Técnico, Universidade de Lisboa.
8. Hip arthroscopy with initial access to the peripheral compartment: a detailed step-by-step technique description10.1016/J.EATS.2020.07.006 ↗
9. Hip joint contact pressure and force: a scoping review of in vivo and cadaver studies10.1302/2046-3758.1212.BJR-2022-0461.R2 ↗
10. Femoroacetabular contact force measurement in hip arthroscopy. Surgical technique10.1016/j.eats.2024.103037 ↗
11. Hip arthroscopy without traction: in vivo anatomy of the peripheral hip joint cavity10.1053/JARS.2001.25342 ↗
12. Management options for femoroacetabular impingement: a systematic review of symptom and structural outcomes10.1016/J.JOCA.2016.04.014 ↗
13. Three-dimensional printed exoskeletons and orthoses for the upper limb—a systematic review10.1097/PXR.0000000000000318 ↗
14. Prevalence of femoroacetabular impingement imaging findings in asymptomatic volunteers: a systematic review10.1016/J.ARTHRO.2014.11.042 ↗
15. 3D printing for preoperative planning and surgical training: a review10.1007/S10544-018-0301-9 ↗
16. The use of rapid prototyping to assist medical applications10.1108/13552540610637273 ↗
17. Effect of temperature on the mechanical properties of 3D-printed PLA tensile specimens10.1108/RPJ-04-2017-0055 ↗
18. The Warwick agreement on femoroacetabular impingement syndrome (FAI syndrome): an international consensus statement10.1136/bjsports-2016-096743 ↗
19. Evaluation of commercial force-sensing resistors
20. Measurement of hip contact pressure during arthroscopic femoroacetabular impingement surgery10.1016/J.EATS.2016.11.010 ↗
21. Effect of porosity and crystallinity on 3D printed PLA properties10.3390/POLYM11091487 ↗
22. Why are tapes better than wires in knotless rotator cuff repairs? An evaluation of force, pressure and contact area in a tendon bone unit mechanical model10.1186/S40634-020-00321-Y ↗
23. Mechanical consequences at the tendon-bone interface of different medial row knotless configurations and lateral row tension in a simulated rotator cuff repair10.1186/S40634-022-00536-1 ↗
24. Advances in FAI imaging: a focused review10.1007/S12178-020-09663-7 ↗
25. Imaging prevalence of femoroacetabular impingement in symptomatic patients, athletes, and asymptomatic individuals: a systematic review10.1016/J.EJRAD.2015.10.016 ↗
26. The Lisbon Agreement on femoroacetabular impingement imaging—part 1: overview10.1007/S00330-020-06822-9 ↗
27. Femoroacetabular impingement and the cam-effect: a MRI-based quantitative anatomical study of the femoral head-neck offset10.1302/0301-620X.83B2.0830171 ↗
28. Mechanical performance of 3D printed polylactide during degradation10.1016/J.ADDMA.2020.101764 ↗
29. Product design by additive manufacturing for water environments: study of degradation and absorption behavior of PLA and PETG10.3390/POLYM13071036 ↗
30. Application of the flexiforce contact surface force sensor to continuous extraocular compression monitoring during craniotomy for cerebral aneurysms10.1097/ANA.0B013E3181BEE662 ↗
31. 2019
32. How to sterilize polylactic acid based medical devices?10.3390/POLYM13132115 ↗
33. Biocompatibility and safety of PLA and its copolymers10.1016/J.ADDR.2016.03.012 ↗
34. Residual deformity is the most common reason for revision hip arthroscopy: a three-dimensional CT study10.1007/S11999-014-4069-9 ↗
35. A cadaveric study of Cam-type femoroacetabular impingement: biomechanical comparison of contact pressures between cam morphology, partial femoral osteoplasty, and complete femoral osteoplasty10.1016/J.ARTHRO.2020.05.021 ↗
36. Evaluation of force sensing resistors for the measurement of interface pressures in lower limb prosthetics10.1115/1.4043561 ↗
37. 3D-printing techniques in a medical setting: a systematic literature review10.1186/S12938-016-0236-4 ↗
38. Force sensing resistorsTM a review of the technology10.1109/ELECTR.1991.718294 ↗
39. A review on degradation mechanisms of polylactic acid: hydrolytic, photodegradative, microbial, and enzymatic degradation10.1002/PEN.25511 ↗