Biomedical porous Ti-15Mo alloys were prepared by microwave sintering using ammonium hydrogen carbonate (NH4HCO3) as the space holder agent to adjust the porosity and mechanical properties. The porous Ti-15Mo alloys are dominated by β-Ti phase with a little α-Ti phase, and the proportion of α and β phase has no significant difference as the NH4HCO3 content increases. The porosities and the average pore sizes of the porous Ti-15Mo alloys increase with increase of the contents of NH4HCO3, while all of the compressive strength, elastic modulus and bending strength decrease. However, the compressive strength, bending strength and the elastic modulus are higher or close to those of natural bone. The surface of the porous Ti-15Mo alloy was further modified by hydrothermal treatment, after which Na2Ti6O13 layers with needle and flake-like clusters were formed on the outer and inner surface of the porous Ti-15Mo alloy. The hydrothermally treated porous Ti-15Mo alloy is completely covered by the Ca-deficient apatite layers after immersed in SBF solution for 14 d, indicating that it possesses high apatiteforming ability and bioactivity. These results demonstrate that the hydrothermally treated microwave sintered porous Ti-15Mo alloys could be a promising candidate as the bone implant.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (56)

Show source-provided references
1. Wu S, Liu X, Yeung KWK, et al. Biomimetic porous scaffolds for bone tissue engineering. Mater Sci Eng-R-Rep, 2014, 80: 1–3610.1016/j.mser.2014.04.001 ↗
2. Rack HJ, Qazi JI. Titanium alloys for biomedical applications. Mater Sci Eng-C, 2006, 26: 1269–127710.1016/j.msec.2005.08.032 ↗
3. Niinomi M. Biologically and mechanically biocompatible titanium alloys. Mater Trans, 2008, 49: 2170–217810.2320/matertrans.L-MRA2008828 ↗
4. Geetha M, Singh AK, Asokamani R, et al. Ti based biomaterials, the ultimate choice for orthopaedic implants–A review. Prog Mater Sci, 2009, 54: 397–42510.1016/j.pmatsci.2008.06.004 ↗
5. Krishna BV, Bose S, Bandyopadhyay A. Low stiffness porous Ti structures for load-bearing implants. Acta Biomater, 2007, 3: 997–100610.1016/j.actbio.2007.03.008 ↗
6. Nagels J, Stokdijk M, Rozing PM. Stress shielding and bone resorption in shoulder arthroplasty. J Shoulder Elbow Surgery, 2003, 12: 35–3910.1067/mse.2003.22 ↗
7. Rao S, Ushida T, Tateishi T, et al. Effect of Ti, Al, and V ions on the relative growth rate of fibroblasts (L929) and osteoblasts (MC3T3-E1) cells. Biomed Mater Eng, 1996, 6: 79–86
8. Ho WF, Ju CP, Lin JH. Structure and properties of cast binary Ti-Mo alloys. Biomaterials, 1999, 20: 2115–212210.1016/S0142-9612(99)00114-3 ↗
9. Li YH, Chen RB, Qi G, et al. Powder sintering of porous Ti-15Mo alloy from TiH2 and Mo powders. J Alloys Compd, 2009, 485: 215–21810.1016/j.jallcom.2009.06.003 ↗
10. Gao Z, Li Q, He F, et al. Mechanical modulation and bioactive surface modification of porous Ti-10Mo alloy for bone implants. Mater Des, 2012, 42: 13–2010.1016/j.matdes.2012.05.041 ↗
11. Liu X, Chu P, Ding C. Surface modification of titanium, titanium alloys, and related materials for biomedical applications. Mater Sci Eng-R-Rep, 2004, 47: 49–12110.1016/j.mser.2004.11.001 ↗
12. Cardoso FF, Ferrandini PL, Lopes ESN, et al. Ti-Mo alloys employed as biomaterials: effects of composition and aging heat treatment on microstructure and mechanical behavior. J Mech Behav BioMed Mater, 2014, 32: 31–3810.1016/j.jmbbm.2013.11.021 ↗
13. Wang BL, Li L, Zheng YF. In vitro cytotoxicity and hemocompatibility studies of Ti-Nb, Ti-Nb-Zr and Ti-Nb-Hf biomedical shape memory alloys. Biomed Mater, 2010, 5: 04410210.1088/1748-6041/5/4/044102 ↗
14. Kuroda D, Niinomi M, Morinaga M, et al. Design and mechanical properties of new β type titanium alloys for implant materials. Mater Sci Eng-A, 1998, 243: 244–24910.1016/S0921-5093(97)00808-3 ↗
15. Zhou YL, Niinomi M. Ti-25Ta alloy with the best mechanical compatibility in Ti-Ta alloys for biomedical applications. Mater Sci Eng-C, 2009, 29: 1061–106510.1016/j.msec.2008.09.012 ↗
16. American Society for Testing and Materials. Standard specification for wrought titanium-15 molybdenum alloy for surgical implant application, ASTM F2066-08, American Society for Testing and Materials, Philadelphia, 2008. 1–5
17. Kumar S, Narayanan TSNS. Corrosion behaviour of Ti-15Mo alloy for dental implant applications. J Dentistry, 2008, 36: 500–50710.1016/j.jdent.2008.03.007 ↗
18. Somsanith N, Narayanan TSNS, Kim YK, et al. Surface medication of Ti-15Mo alloy by thermal oxidation: evaluation of surface characteristics and corrosion resistance in Ringer’s solution. Appl Surf Sci, 2015, 356: 1117–112610.1016/j.apsusc.2015.08.181 ↗
19. Yamaguchi S, Anchieta RB, Guastaldi FPS, et al. In silico analysis of the biomechanical stability of commercially pure Ti and Ti-15Mo plates for the treatment of mandibular angle fracture. J Oral Maxillofacial Surgery, 2017, 75: 1004.e1–1004.e910.1016/j.joms.2016.12.043 ↗
20. Mour M, Das D, Winkler T, et al. Advances in porous biomaterials for dental and orthopaedic applications. Materials, 2010, 3: 2947–297410.3390/ma3052947 ↗
21. Hsu HC, Wu SC, Hsu SK, et al. Effect of ball milling on properties of porous Ti-7.5Mo alloy for biomedical applications. J Alloys Compd, 2014, 582: 793–80110.1016/j.jallcom.2013.08.147 ↗
22. Lewis G. Properties of open-cell porous metals and alloys for orthopaedic applications. J Mater Sci-Mater Med, 2013, 24: 2293–232510.1007/s10856-013-4998-y ↗
23. Yang D, Guo Z, Shao H, et al. Mechanical properties of porous Ti-Mo and Ti-Nb alloys for biomedical application by gelcasting. Procedia Eng, 2012, 36: 160–16710.1016/j.proeng.2012.03.025 ↗
24. Xie F, He X, Lu X, et al. Preparation and properties of porous Ti-10Mo alloy by selective laser sintering. Mater Sci Eng-C, 2013, 33: 1085–109010.1016/j.msec.2012.11.037 ↗
25. Xie F, He X, Cao S, et al. Influence of pore characteristics on microstructure, mechanical properties and corrosion resistance of selective laser sintered porous Ti-Mo alloys for biomedical applications. Electrochim Acta, 2013, 105: 121–12910.1016/j.electacta.2013.04.105 ↗
26. Hsu HC, Wu SC, Hsu SK, et al. Processing and mechanical properties of porous Ti-7.5Mo alloy. Mater Des, 2013, 47: 21–2610.1016/j.matdes.2012.12.043 ↗
27. Tang CY, Zhang LN, Wong CT, et al. Fabrication and characteristics of porous NiTi shape memory alloy synthesized by microwave sintering. Mater Sci Eng-A, 2011, 528: 6006–601110.1016/j.msea.2011.04.040 ↗
28. Xu JL, Bao LZ, Liu AH, et al. Microstructure, mechanical properties and superelasticity of biomedical porous NiTi alloy prepared by microwave sintering. Mater Sci Eng-C, 2015, 46: 387–39310.1016/j.msec.2014.10.053 ↗
29. Choy MT, Tang CY, Chen L, et al. In vitro and in vivo performance of bioactive Ti6Al4V/TiC/HA implants fabricated by a rapid microwave sintering technique. Mater Sci Eng-C, 2014, 42: 746–75610.1016/j.msec.2014.06.015 ↗
30. Choy MT, Tang CY, Chen L, et al. Microwave assisted-in situ synthesis of porous titanium/calcium phosphate composites and their in vitro apatite-forming capability. Composites Part B-Eng, 2015, 83: 50–5710.1016/j.compositesb.2015.08.046 ↗
31. Mishra RR, Sharma AK. Microwave-material interaction phenomena: heating mechanisms, challenges and opportunities in material processing. Composites Part A-Appl Sci Manufacturing, 2016, 81: 78–9710.1016/j.compositesa.2015.10.035 ↗
32. Oghbaei M, Mirzaee O. Microwave versus conventional sintering: a review of fundamentals, advantages and applications. J Alloys Compd, 2010, 494: 175–18910.1016/j.jallcom.2010.01.068 ↗
33. Das S, Mukhopadhyay AK, Datta S, et al. Prospects of microwave processing: an overview. Bull Mater Sci, 2009, 32: 1–1310.1007/s12034-009-0001-4 ↗
34. Kazek-Kęsik A, Krok-Borkowicz M, Pamuła E, et al. Electrochemical and biological characterization of coatings formed on Ti-15Mo alloy by plasma electrolytic oxidation. Mater Sci Eng-C, 2014, 43: 172–18110.1016/j.msec.2014.07.021 ↗
35. Babilas D, Służalska K, Krząkała A, et al. Plasma electrolytic oxidation of a Ti-15Mo alloy in silicate solutions. Mater Lett, 2013, 100: 252–25610.1016/j.matlet.2013.03.047 ↗
36. Oliveira NTC, Guastaldi AC, Piazza S, et al. Photo-electrochemical investigation of anodic oxide films on cast Ti-Mo alloys. I. Anodic behaviour and effect of alloy composition. Electrochim Acta, 2009, 54: 1395–1402
37. Babilas D, Urbańczyk E, Sowa M, et al. On the electropolishing and anodic oxidation of Ti-15Mo alloy. Electrochim Acta, 2016, 205: 256–26510.1016/j.electacta.2016.01.218 ↗
38. Ho WF, Lai CH, Hsu HC, et al. Surface modification of a lowmodulus Ti-7.5Mo alloy treated with aqueous NaOH. Surf Coatings Tech, 2009, 203: 3142–315010.1016/j.surfcoat.2009.03.042 ↗
39. Escada ALA, Rodrigues Jr D, Machado JPB, et al. Surface characterization of Ti-7.5Mo alloy modified by biomimetic method. Surf Coatings Tech, 2010, 205: 383–38710.1016/j.surfcoat.2010.06.067 ↗
40. Kim HM, Miyaji F, Kokubo T, et al. Preparation of bioactive Ti and its alloys via simple chemical surface treatment. J Biomed Mater Res, 1996, 32: 409–41710.1002/(SICI)1097-4636(199611)32:3<409::AID-JBM14>3.0.CO;2-B ↗
41. Ou SF, Wang CY. Fabrication of a hydroxyapatite-containing coating on Ti-Ta alloy by electrical discharge coating and hydrothermal treatment. Surf Coatings Tech, 2016, 302: 238–24310.1016/j.surfcoat.2016.06.013 ↗
42. Liu F, Song Y, Wang F, et al. Formation characterization of hydroxyapatite on titanium by microarc oxidation and hydrothermal treatment. J Biosci Bioeng, 2005, 100: 100–10410.1263/jbb.100.100 ↗
43. Liu X, Zhang Z, Wu Y. Absorption properties of carbon black/silicon carbide microwave absorbers. Composites Part B-Eng, 2011, 42: 326–32910.1016/j.compositesb.2010.11.009 ↗
44. Li BY, Rong LJ, Li YY. The influence of addition of TiH2 in elemental powder sintering porous Ni-Ti alloys. Mater Sci Eng-A, 2000, 281: 169–17510.1016/S0921-5093(99)00729-7 ↗
45. Liu Y, Chen LF, Tang HP, et al. Design of powder metallurgy titanium alloys and composites. Mater Sci Eng-A, 2006, 418: 25–3510.1016/j.msea.2005.10.057 ↗
46. Li DS, Zhang YP, Ma X, et al. Space-holder engineered porous NiTi shape memory alloys with improved pore characteristics and mechanical properties. J Alloys Compd, 2009, 474: L1–L510.1016/j.jallcom.2008.06.043 ↗
47. Staiger MP, Pietak AM, Huadmai J, et al. Magnesium and its alloys as orthopedic biomaterials: a review. Biomaterials, 2006, 27: 1728–173410.1016/j.biomaterials.2005.10.003 ↗
48. Itälä AI, Ylänen HO, Ekholm C, et al. Pore diameter of more than 100 μm is not requisite for bone ingrowth in rabbits. J Biomed Mater Res, 2001, 58: 679–68310.1002/jbm.1069 ↗
49. Bertheville B. Porous single-phase NiTi processed under Ca reducing vapor for use as a bone graft substitute. Biomaterials, 2006, 27: 1246–125010.1016/j.biomaterials.2005.09.014 ↗
50. Kujala S, Ryhänen J, Danilov A, et al. Effect of porosity on the osteointegration and bone ingrowth of a weight-bearing nickeltitanium bone graft substitute. Biomaterials, 2003, 24: 4691–469710.1016/S0142-9612(03)00359-4 ↗
51. Li JP, Li SH, Van Blitterswijk CA, et al. A novel porous Ti6Al4V: characterization and cell attachment. J Biomed Mater Res, 2005, 73A: 223–23310.1002/jbm.a.30278 ↗
52. Barrabés M, Sevilla P, Planell JA, et al. Mechanical properties of nickel-titanium foams for reconstructive orthopaedics. Mater Sci Eng-C, 2008, 28: 23–2710.1016/j.msec.2007.02.001 ↗
53. Hench LL. Bioceramics. J Am Ceramic Soc, 2005, 81: 1705–172810.1111/j.1151-2916.1998.tb02540.x ↗
54. Sasikumar Y, Rajendran N. Influence of surface modification on the apatite formation and corrosion behavior of Ti and Ti-15Mo alloy for biomedical applications. Mater Chem Phys, 2013, 138: 114–12310.1016/j.matchemphys.2012.11.025 ↗
55. Kokubo T, Kim HM, Kawashita M. Novel bioactive materials with different mechanical properties. Biomaterials, 2003, 24: 2161–217510.1016/S0142-9612(03)00044-9 ↗
56. Kokubo T, Takadama H. How useful is SBF in predicting in vivo bone bioactivity? Biomaterials, 2006, 27: 2907–291510.1016/j.biomaterials.2006.01.017 ↗