journal article·2018-05

High precision magnetometer for geomagnetic exploration onboard of the China Seismo-Electromagnetic Satellite

BingJun Cheng, Bin Zhou, Werner Magnes, Roland Lammegger, Andreas Pollinger

Publisher page

Abstract

The China Seismo-Electromagnetic Satellite (CSES) is the first platform of China’s earthquake observation system in space and the first satellite of China’s geophysical field detection missions. The high precision magnetometer (HPM), which contains two fluxgate sensors and a coupled dark state magnetometer (CDSM), measures the vector of the Earth’s magnetic field with a bandwidth from DC to 15 Hz. The two fluxgate sensors are in a gradiometer configuration in order to reduce satellite interferences. Additionally, the CDSM sensor measures the scalar value of the magnetic field with higher accuracy and stability. Several data processing and calibration methods have been prepared to get accurate vector magnetic field data. This includes the calibration of each of the three sensors, the absolute vector correction algorithm, the spacecraft magnetic interference elimination and the coordinate transformation method. Also the instrument performances based on ground calibration activities are shown in this article.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Earthquake Detection and Analysis · Geomagnetism and Paleomagnetism Studies · Ionosphere and magnetosphere dynamics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Shen X, Zhang X, Wang L, et al. The earthquake-related disturbances in ionosphere and project of the first China seismo-electromagnetic satellite. Earthq Sci, 2011, 24: 639–65010.1007/s11589-011-0824-0 ↗
2. Thomas A P, Frederick F M, Lewis D E. The geomagnetic field and its measurement: Introduction and magnetic field satellite (MAGSAT) glossary. Johns Hopkins APL Tech Digest, 1980, 1: 161–170
3. Nielsen O V, Petersen J R, Primdahl F, et al. Development, construction and analysis of the “OErsted” fluxgate magnetometer. Meas Sci Technol, 1995, 6: 1099–111510.1088/0957-0233/6/8/004 ↗
4. Olsen N, Tøffner-Clausen L, Sabaka T J, et al. Calibration of the Ørsted vector magnetometer. Earth Planet Space, 2003, 55: 11–1810.1186/BF03352458 ↗
5. Shen X H, Zhang X M, Yuan S G, et al. The state-of-the-art of the China seismo-electeomagnetic satellite mission. Sci China Tech Sci, 2018, 61: 634–64210.1007/s11431-018-9242-0 ↗
6. Cao J B, Zeng L, Zhan F, et al. The electromagnetic wave experiment for CSES mission: search coil magnetometer. Sci China Tech Sci, 2018, 61: 653–65810.1007/s11431-018-9241-7 ↗
7. Lin J, Shen X H, Wang L W. CSES GNSS ionospheric inversion technique, validation and error analysis. Sci China Tech Sci, 2018, 61: 669–67710.1007/s11431-018-9245-6 ↗
8. Ambrosi G, Bartocci S, Basara L, et al. The HEPD particle detector of the CSES satellite mission for investigating seismo-associated perturbations of the Van Allen belts. Sci China Tech Sci, 2018, 61: 643–65210.1007/s11431-018-9234-9 ↗
9. Wang L W, Shen X H, Zhang Y, et al. Developing progress of China seismo-electromagnetic satellite project. Acta Seismol Sin, 2016, 38: 376–385
10. Ding J H, Shen X H, Pan W Y, et al. Seiemo-electromagenetism precursor research progress. Chin J Radio Sci, 2006, 21: 791–800
11. Cheng B J, Zhou B, Magnes W, et al. Performance of the engineering model of the CSES high precision magnetometer. In: Proceeding of the IEEE Sensors, 2015. Busan, 2015. 1933–1936
12. Zhou B, Cheng B J, Zhang Y T, et al. Magnetic field detection method of China seismo-electromagnetic satellite. Chin J Space Sci, 2014, 34: 843–84810.11728/cjss2014.06.843 ↗
13. Lammegger R. Method and device for measuring magnetic fields. US Patent App. 12/664,782, 2008-06-12
14. Pollinger A, Ellmeier M, Magnes M, et al. Enable the inherent omnidirectionality of an absolute coupled dark state magnetometer for e.g. scientific space applications. In: Instrumentation & Measurement Technology Conference. Graz, 2012. 33–36
15. Pollinger A, Lammegger R, Magnes W, et al. Coupled dark state magnetometer for the China seismo-electromagnetic satellite. Measurement Sci Tech, 2018, in press
16. Zhang Z Q, Li L, Zhou B, et al. A method of in-orbit calibration of fluxgate magnetometer based on the measurement of absolute scalar magnetometer. Chin J Space Sci, 2014, 34: 235–24110.11728/cjss2014.02.235 ↗
17. Chen S W. Control and measure of satellite magnetic cleanliness. Progr Geophys, 2009, 24: 797–800
18. von Yin F. Mathematic approaches for the calibration of the CHAMP satellite magnetic field measurements. Dissertation for Doctoral Degree. Potsdam: Institutional Repository of the University of Potsdam, 2009. 11–17
19. Narvaez P. The magnetostatic cleanliness program for the cassini spacecraft. Space Sci Rev, 2004, 114: 385–39410.1007/s11214-004-1433-1 ↗
20. Wang X F, Han X D, Yang C M. Method of earth’s magnetic field fluctuation compensated by Cs magnetometer. J Transducer Tech, 2004, 23: 47–49