journal article·2023-01

Claw-shaped flexible and low-impedance conductive polymer electrodes for EEG recordings: Anemone dry electrode

ZhongYan Shi, Bo Jiang, ShiChao Liang, JiangTao Zhang, DingJie Suo, JingLong Wu, DuanDuan Chen, GuangYing Pei, TianYi Yan

Publisher page

Abstract

Electroencephalogram (EEG) signals provide important brain information in healthcare settings. Wet electrodes have several limitations, including their time-consuming preparation and no long-term acquisition, and dry electrodes have become a promising candidate. However, dry electrodes face several challenges related to signal quality, comfort, conductivity and cost. This study aims to develop and evaluate a novel dry electrode for EEG recordings. The electrode material properties are characterized by electrochemical, mechanical force, and skin measurements. The electrode performance is evaluated by comparing the impedance, signal-to-noise ratio (SNR), and EEG signal features of the proposed electrode with those of a wet electrode and two commercial dry electrodes. The dry electrode design is based on the biological structure of the sea anemone and demonstrates an improved scalp fit and reduced signal noise and motion artifacts. The electrode materials include advanced conducting polymers combined with thermoplastic elastomers (TPEs) and carbon nanotubes (CNTs), which exhibit good electrical conductivity, mechanical properties, and safety. A low-cost injection molding fabrication method is proposed. The dry electrodes show a scalp contact impedance of 7 kΩ at 20 Hz, which is lower than that of wet and commercial dry electrodes. Resting-state EEG and event-related potential signals collected by the anemone dry electrode achieved more than 90% similarity with signals acquired by wet electrodes. Thus, a low-cost, comfortable anemone dry electrode that exhibits excellent EEG recording performance is presented. The anemone dry electrode represents an important technological advance in material and structural design for EEG recording sensors.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: EEG and Brain-Computer Interfaces · Advanced Sensor and Energy Harvesting Materials · Neuroscience and Neural Engineering

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (56)

Show source-provided references
1. Duan F, Jia H, Zhang Z W, et al. On the robustness of EEG tensor completion methods. Sci China Tech Sci, 2021, 64: 1828–184210.1007/s11431-020-1839-5 ↗
2. Feng Z, Sun Y, Qian L, et al. Design a novel BCI for neurorehabilitation using concurrent LFP and EEG features: A case study. IEEE Trans Biomed Eng, 2022, 69: 1554–156310.1109/TBME.2021.3115799 ↗
3. Hinrichs H, Scholz M, Baum A K, et al. Comparison between a wireless dry electrode EEG system with a conventional wired wet electrode EEG system for clinical applications. Sci Rep, 2020, 10: 521810.1038/s41598-020-62154-0 ↗
4. Fayyaz Shahandashti P, Pourkheyrollah H, Jahanshahi A, et al. Highly conformable stretchable dry electrodes based on inexpensive flex substrate for long-term biopotential (EMG/ECG) monitoring. Sens Actuat A-Phys, 2019, 295: 678–68610.1016/j.sna.2019.06.041 ↗
5. Kam J W Y, Griffin S, Shen A, et al. Systematic comparison between a wireless EEG system with dry electrodes and a wired EEG system with wet electrodes. NeuroImage, 2019, 184: 119–12910.1016/j.neuroimage.2018.09.012 ↗
6. Li G L, Wu J T, Xia Y H, et al. Review of semi-dry electrodes for EEG recording. J Neural Eng, 2020, 17: 05100410.1088/1741-2552/abbd50 ↗
7. Pei G, Wu J, Chen D, et al. Effects of an integrated neurofeedback system with dry electrodes: EEG acquisition and cognition assessment. Sensors, 2018, 18: 339610.3390/s18103396 ↗
8. Liu J, Liu X, He E, et al. A novel dry-contact electrode for measuring electroencephalography signals. Sens Actuat A-Phys, 2019, 294: 73–8010.1016/j.sna.2019.05.017 ↗
9. Fu Y, Zhao J, Dong Y, et al. Dry electrodes for human bioelectrical signal monitoring. Sensors, 2020, 20: 365110.3390/s20133651 ↗
10. Li G, Wu J, Xia Y, et al. Towards emerging EEG applications: A novel printable flexible Ag/AgCl dry electrode array for robust recording of EEG signals at forehead sites. J Neural Eng, 2020, 17: 02600110.1088/1741-2552/ab71ea ↗
11. Liu W, Zhou W, Liu S, et al. Electrical impedance performance of metal dry bioelectrode with different surface coatings. Sens Actuat A-Phys, 2018, 269: 515–52310.1016/j.sna.2017.12.006 ↗
12. Ren L, Jiang Q, Chen Z, et al. Flexible microneedle array electrode using magnetorheological drawing lithography for bio-signal monitoring. Sens Actuat A-Phys, 2017, 268: 38–4510.1016/j.sna.2017.10.042 ↗
13. Rdest M, Janas D. Carbon nanotube wearable sensors for health diagnostics. Sensors, 2021, 21: 584710.3390/s21175847 ↗
14. Rathinavel S, Priyadharshini K, Panda D. A review on carbon nanotube: An overview of synthesis, properties, functionalization, characterization, and the application. Mater Sci Eng-B, 2021, 268: 11509510.1016/j.mseb.2021.115095 ↗
15. Silva-Neto H A, Santhiago M, Duarte L C, et al. Fully 3D printing of carbon black-thermoplastic hybrid materials and fast activation for development of highly stable electrochemical sensors. Sens Actuat B-Chem, 2021, 349: 13072110.1016/j.snb.2021.130721 ↗
16. Clark K M, Henry C S. Thermoplastic Electrode (TPE)-based Enzymatic Glucose Sensor Using Polycaprolactone-graphite Composites. Electroanalysis, 2021, doi: https://doi.org/10.1002/elan.20210044610.1002/elan.202100446 ↗
17. Yang L, Liu Q, Zhang Z, et al. Materials for dry electrodes for the electroencephalography: Advances, challenges, perspectives. Adv Mater Technologies, 2022, 7: 210061210.1002/admt.202100612 ↗
18. Kimura M, Nakatani S, Nishida S I, et al. 3D printable dry EEG electrodes with coiled-spring prongs. Sensors, 2020, 20: 473310.3390/s20174733 ↗
19. Harati A, Jahanshahi A. A reliable stretchable dry electrode for monitoring of EEG signals. Sens Actuat A-Phys, 2021, 326: 11272710.1016/j.sna.2021.112727 ↗
20. Gao K P, Yang H J, Wang X L, et al. Soft pin-shaped dry electrode with bristles for EEG signal measurements. Sens Actuat A-Phys, 2018, 283: 348–36110.1016/j.sna.2018.09.045 ↗
21. Grozea C, Voinescu C D, Fazli S. Bristle-sensors—low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications. J Neural Eng, 2011, 8: 02500810.1088/1741-2560/8/2/025008 ↗
22. Huang Y J, Wu C Y, Wong A M K, et al. Novel active comb-shaped dry electrode for EEG measurement in hairy site. IEEE Trans Biomed Eng, 2015, 62: 256–26310.1109/TBME.2014.2347318 ↗
23. Kim J, Lee J, Han C, et al. An instant donning multi-channel EEG headset (with comb-shaped dry electrodes) and BCI applications. Sensors, 2019, 19: 153710.3390/s19071537 ↗
24. Su K M, Yu M H, Su H Y, et al. Investigating biomechanics of different materials and angles of blades of forceps for operative delivery by finite element analysis. J Mech Med Biol, 2016, 16: 165004610.1142/S0219519416500469 ↗
25. Chen W, Damalero R, Lim R, et al. Simulation analysis of a wearable dry EEG electrodes for epilepsy monitoring. In: Proceedings of the 19th IEEE Electronics Packaging Technology Conference (EPTC). Singapore, 201710.1109/EPTC.2017.8277501 ↗
26. Gennari C G M, Quaroni G M G, Creton C, et al. SEBS block co-polymers as novel materials to design transdermal patches. Int J Pharm, 2020, 575: 11897510.1016/j.ijpharm.2019.118975 ↗
27. Antônio dos Santos Filho E, Luna C, Siqueira D, et al. Reuse of carbon fiber waste to produce composites with polypropylene. The effect of styrene-(ethylene-butylene)-styrene grafted with maleic anhydride and ethylene-propylene-diene grafted with maleic anhydride copolymers. Polym Compos, 2021, 42: 6182–619510.1002/pc.26295 ↗
28. Stauffer F, Thielen M, Sauter C, et al. Skin conformal polymer electrodes for clinical ECG and EEG recordings. Adv Healthcare Mater, 2018, 7: 170099410.1002/adhm.201700994 ↗
29. Freeborn T, Fu B. Fatigue-induced cole electrical impedance model changes of biceps tissue bioimpedance. Fractal Fract, 2018, 2: 2710.3390/fractalfract2040027 ↗
30. Erani F, Zolotova N, Vanderschelden B, et al. Abstract TP314: EEG has high precision for diagnosing stroke hours after onset. Stroke, 2019, 50: ATP31410.1161/str.50.suppl_1.TP314 ↗
31. Gui P, Jiang Y, Zang D, et al. Assessing the depth of language processing in patients with disorders of consciousness. Nat Neurosci, 2020, 23: 761–77010.1038/s41593-020-0639-1 ↗
32. Chen Y H, de Beeck M, Vanderheyden L, et al. Soft, comfortable polymer dry electrodes for high quality ECG and EEG recording. Sensors, 2014, 14: 23758–2378010.3390/s141223758 ↗
33. Zhang Y X, Moore D R, Guiraud J, et al. Auditory discrimination learning: Role of working memory. PLoS ONE, 2016, 11: e014732010.1371/journal.pone.0147320 ↗
34. Delorme A, Makeig S. EEGLAB: An open source toolbox for analysis of single-trial EEG dynamics including independent component analysis. J Neurosci Methods, 2004, 134: 9–2110.1016/j.jneumeth.2003.10.009 ↗
35. Luo C H, Ma W J, Juang W H, et al. An ECG acquisition system prototype design with flexible PDMS dry electrodes and variable transform length DCT-IV based compression algorithm. IEEE Sensors J, 2016, 16: 8244–8254
36. Randazzo M, Priefer R, Smith P J, et al. Neural correlates of modality-sensitive deviance detection in the audiovisual oddball paradigm. Brain Sci, 2020, 10: 32810.3390/brainsci10060328 ↗
37. Klunder K J, Nilsson Z, Sambur J B, et al. Patternable solvent-processed thermoplastic graphite electrodes. J Am Chem Soc, 2017, 139: 12623–1263110.1021/jacs.7b06173 ↗
38. Ribeiro F, Sena-Cruz J, Branco F G, et al. Analytical hybrid effect prediction and evolution of the tensile response of unidirectional hybrid fibre-reinforced polymers composites for civil engineering applications. J Composite Mater, 2020, 54: 3205–322810.1177/0021998320911956 ↗
39. Habibzadeh Tonekabony Shad E, Molinas M, Ytterdal T. Impedance and noise of passive and active dry EEG electrodes: A review. IEEE Sens J, 2020, 20: 14565–1457710.1109/JSEN.2020.3012394 ↗
40. Pei G, Yang R, Shi Z, et al. Enhancing working memory based on mismatch negativity neurofeedback in subjective cognitive decline patients: A preliminary study. Front Aging Neurosci, 2020, 12: 26310.3389/fnagi.2020.00263 ↗
41. Gao K P, Yang H J, Liao L L, et al. A novel bristle-shaped semi-dry electrode with low contact impedance and ease of use features for EEG signal measurements. IEEE Trans Biomed Eng, 2020, 67: 750–76110.1109/TBME.2019.2920711 ↗
42. Lee S, Shin Y, Kumar A, et al. Dry electrode-based fully isolated EEG/fNIRS hybrid brain-monitoring system. IEEE Trans Biomed Eng, 2019, 66: 1055–106810.1109/TBME.2018.2866550 ↗
43. Kireev D, Ameri S K, Nederveld A, et al. Fabrication, characterization and applications of graphene electronic tattoos. Nat Protoc, 2021, 16: 2395–241710.1038/s41596-020-00489-8 ↗
44. Ren L, Chen Z, Wang H, et al. Fabrication of bendable microneedlearray electrode by magnetorheological drawing lithography for electroencephalogram recording. IEEE Trans Instrum Meas, 2020, 69: 8328–833410.1109/TIM.2020.2990523 ↗
45. Galassi T V, Antman-Passig M, Yaari Z, et al. Long-term in vivo biocompatibility of single-walled carbon nanotubes. PLoS ONE, 2020, 15: e022679110.1371/journal.pone.0226791 ↗
46. Ben-Shimon Y, Ya’akobovitz A. Flexible and bio-compatible temperature sensors based on carbon nanotube composites. Measurement, 2021, 172: 10888910.1016/j.measurement.2020.108889 ↗
47. Lin C T, Liao L D, Liu Y H, et al. Novel dry polymer foam electrodes for long-term EEG measurement. IEEE Trans Biomed Eng, 2011, 58: 1200–120710.1109/TBME.2010.2102353 ↗
48. Guo X, Pei W, Wang Y, et al. A self-wetting paper electrode for ubiquitous bio-potential monitoring. IEEE Sens J, 2017, 17: 2654–266110.1109/JSEN.2017.2684825 ↗
49. Zhang H, Pei W, Chen Y, et al. A motion interference-insensitive flexible dry electrode. IEEE Trans Biomed Eng, 2016, 63: 1136–114410.1109/TBME.2015.2485269 ↗
50. O’Sullivan M, Temko A, Bocchino A, et al. Analysis of a low-cost EEG monitoring system and dry electrodes toward clinical use in the neonatal ICU. Sensors, 2019, 19: 263710.3390/s19112637 ↗
51. Niu X, Gao X, Liu Y, et al. Surface bioelectric dry electrodes: A review. Measurement, 2021, 183: 10977410.1016/j.measurement.2021.109774 ↗
52. Fiedler P, Muhle R, Griebel S, et al. Contact pressure and flexibility of multipin dry EEG electrodes. IEEE Trans Neural Syst Rehabil Eng, 2018, 26: 750–75710.1109/TNSRE.2018.2811752 ↗
53. Xing X, Pei W, Wang Y, et al. Assessing a novel micro-seepage electrode with flexible and elastic tips for wearable EEG acquisition. Sens Actuat A-Phys, 2018, 270: 262–27010.1016/j.sna.2017.12.048 ↗
54. Li J, Ma Y, Huang D, et al. High-performance flexible microneedle array as a low-impedance surface Biopotential dry Electrode for wearable electrophysiological recording and polysomnography. Nano-Micro Lett, 2022, 14: 13210.1007/s40820-022-00870-0 ↗
55. Krachunov S, Casson A. 3D printed dry EEG electrodes. Sensors, 2016, 16: 163510.3390/s16101635 ↗
56. Laszlo S, Ruiz-Blondet M, Khalifian N, et al. A direct comparison of active and passive amplification electrodes in the same amplifier system. J Neurosci Methods, 2014, 235: 298–30710.1016/j.jneumeth.2014.05.012 ↗