Measures against the adverse impact of natural wind on air-cooled condensers in power plant
Source abstract
Abstract
The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant. It is of use to take various measures against the adverse effect of wind for the performance improvement of air-cooled condensers. Based on representative 2×600 MW direct air-cooled power plant, three ways that can arrange and optimize the flow field of cooling air thus enhance the heat transfer of air-cooled condensers were proposed. The physical and mathematical models of air-cooled condensers with various flow leading measures were presented and the flow and temperature fields of cooling air were obtained by CFD simulation. The back pressures of turbine were calculated for different measures on the basis of the heat transfer model of air-cooled condensers. The results show that the performance of air-cooled condensers is improved thus the back pressure of turbine is lowered to some extent by taking measures against the adverse impact of natural wind.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Adsorption and Cooling Systems · Wind and Air Flow Studies · Aerodynamics and Fluid Dynamics Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (14)
Show source-provided references
1. Tawney R, Khan Z, Zachary J. Economic and performance evaluation of heat sink options in combined cycle applications. ASME J Eng Gas Turbines Power, 2005, 127: 397–40310.1115/1.1839924 ↗
2. Duvenhage K, Kroger D G. The influence of wind on the performance of forced draught air-cooled heat exchangers. J Wind Eng Ind Aero, 1996, 62: 259–27710.1016/S0167-6105(96)00082-7 ↗
3. Liu P Q, Duan H S, Zhao W L. Numerical investigation of hot air recirculation of air-cooled condensers at a large power plant. Appl Therm Eng, 2009, 29: 1927–193410.1016/j.applthermaleng.2008.09.011 ↗
4. Wang Q W, Zhang D J, Zeng M, et al. CFD simulation on a thermal power plant with air-cooled heat exchanger system in north China Author. Eng Comp, 2008, 25: 342–36510.1108/02644400810874958 ↗
5. Hotchkiss P J, Meyer C J, von Backstrom T W. Numerical investigation into the effect of cross-flow on the performance of axial flow fans in forced draught air-cooled heat exchangers. Appl Therm Eng, 2006, 26: 200–20810.1016/j.applthermaleng.2005.05.012 ↗
6. Meyer C J, Kroger D G. Plenum chamber flow losses in forced draught air-cooled heat exchangers. Appl Therm Eng, 1998, 18: 875–89310.1016/S1359-4311(97)00109-9 ↗
7. Meyer C J, Kroger D G. Numerical investigation of the effect of fan performance on forced draught air-cooled heat exchanger plenum chamber aerodynamic behavior. Appl Therm Eng, 2004, 24: 359–37110.1016/j.applthermaleng.2003.08.009 ↗
8. Duvenhage K, Vermeulen J A, Meyer C J, et al. Flow distortions at the fan inlet of forced-draught air-cooled heat exchangers. Appl Therm Eng, 1996, 16: 741–75210.1016/1359-4311(95)00063-1 ↗
9. Bredell J R, Kroger D G, Thiart G D. Numerical investigation of fan performance in a forced draft air-cooled steam condenser. Appl Therm Eng, 2006, 26: 846–85210.1016/j.applthermaleng.2005.09.020 ↗
10. Meyer C J, Kroger D G. Air-cooled heat exchanger inlet flow losses. Appl Therm Eng, 2001, 21: 771–78610.1016/S1359-4311(00)00083-1 ↗
11. Gu Zh F, Li H, Zhang W H, et al. Wind tunnel simulation on re-circulation of air-cooled condensers of a power plant. J Wind Eng Ind Aero, 2005, 93: 509–52010.1016/j.jweia.2005.05.001 ↗
12. Gu Z, Chen X, Lubitz W, et al. Wind tunnel simulation of exhaust recirculation in an air-cooling system at a large power plant. Int J Therm Sci, 2007, 46: 308–31710.1016/j.ijthermalsci.2006.04.007 ↗
13. Yang L J, Du X Z, Yang Y P, et al. Performance evaluation for direct air-cooled steam condensers in power plant (in Chinese). Proceedings of the CSEE, 2007, 27: 59–63
14. Ding E M. Air-Cooled Technology in Power Plant (in Chinese). Beijing: Hydraulic and Electric Power Press, 1992