journal article·2010-05

Characterizing center pivot irrigation with fixed spray plate sprinklers

HaiJun Yan, HongZhi Jin, YiChao Qian

Publisher page

Abstract

An indoor experiment with a fixed spray plate sprinkler (FSPS) of 36-grooved plate D3000 was conducted to evaluate the discharge-pressure relationship, wetted diameter, effective width, and water application rate in this research. In addition, a field experiment with a center pivot system equipped with the same measured FSPS was carried out to investigate the radial and circular uniformity under different cycle times and settings of the percent-timer. A package of nozzles numbering from #9 (1.79 mm) to #33 (6.55 mm) was tested with a nozzle elevation of 1.2 m and a 20-psi pressure regulator. The results showed that the wetted diameter and average application rate increased with nozzle size, but the effective wetted width and peak instantaneous application rate had no significant relationship with nozzle size. The simulated application rate of the center pivot system using the measured water distribution data of single FSPS was in good agreement with the measured result, which verified that the improved measurement procedure and modified nozzle sizing equation of the D3000 sprayhead in this paper were correct. Reducing the percent-time cycle time from 60 s to 40 s resulted in a slight increase in the radial uniformity coefficients, with an average of 1.09% to 1.17%, while there was no significant influence on the circular uniformity coefficients.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Irrigation Practices and Water Management · Urban Stormwater Management Solutions · Plant Surface Properties and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (19)

Show source-provided references
1. Musick J T, Pringle F B, Walker J W. Sprinkler and furrow irrigation trends: Texas High Plains. Appl Engrg in Agr, 1988, 4: 46–5210.13031/2013.26578 ↗
2. Kincaid D C, Solomon K H, Oliphant J C. Droplet size distribution for irrigation sprinklers. Tran ASAE, 1996, 39: 839–84510.13031/2013.27568 ↗
3. Faci J M, Salvador R, Playán E, et al. Comparison of fixed and rotating spray plate sprinklers. J Irrig Drain Engrg, ASCE, 2001, 127: 224–23310.1061/(ASCE)0733-9437(2001)127:4(224) ↗
4. Deboer D W, Monnens M J. Estimation of drop size and kinetic energy from a rotating spray-plate sprinkler. Trans ASAE, 2001, 44: 1571–1580
5. Deboer D W. Drop and energy characteristics of a rotating spray-plate sprinkler. J Irrig Drain Engrg, ASCE, 2002, 128: 137–14610.1061/(ASCE)0733-9437(2002)128:3(137) ↗
6. Clark G A, Srinivas K, Rogers D H, et al. Measured and simulated uniformity of low drift nozzle sprinklers. Trans ASAE, 2003, 46: 321–33010.13031/2013.12983 ↗
7. Sourell H, Faci J M, Playán E. Performance of rotating spray plate sprinklers in indoor experiments. J Irrig Drain Engrg, ASCE, 2003, 129: 376–38010.1061/(ASCE)0733-9437(2003)129:5(376) ↗
8. Kincaid D C. Application rates from center pivot irrigation with current sprinkler types. Appl Engrg Agr, 2005, 21: 605–61010.13031/2013.18570 ↗
9. Fraisse C W, Heermann D F, Duke H R. Simulation of variable water application with linear-move irrigation systems. Trans ASAE, 1995, 38: 1371–137610.13031/2013.27960 ↗
10. Kohl K D, Kohl R A, Beboer D W. Measurement of low-pressure sprinkler evaporation loss. Trans ASAE, 1987, 30: 1071–107410.13031/2013.30522 ↗
11. Playán E, Garrido S, Faci J M, et al. Characterizing pivot sprinklers using an experimental irrigation machine. Agr Water Manage, 2004, 70: 177–19310.1016/j.agwat.2004.06.004 ↗
12. Omary M, Sumner H. Modeling distribution uniformity for center pivot with small spraying nozzles. ASAE Paper, 1998, 98–2073
13. ASAE S398.1. Procedure for sprinkler testing and performance reporting. St. Joseph, Michigan, 2001
14. ASAE S436.1. Test procedure for determining the uniformity of water distribution of center pivot, corner pivot, and moving lateral irrigation machines equipped with spray or sprinkler nozzles. St. Joseph, Michigan, 2001
15. Bremond B, Molle B. Characterization of rainfall under center pivot: Influence of Measuring procedure. J Irrig Drain Engrg, ASCE, 1995, 121: 347–35310.1061/(ASCE)0733-9437(1995)121:5(347) ↗
16. Christiansen J E. Irrigation by sprinkling. California Agric Exp St Bull, Univ of California, Berkeley, California, 1942
17. Heermann D F, Hein P R. Performance characteristics of self-propelled center pivot sprinkler irrigation system. Trans ASAE, 1968, 11: 11–1510.13031/2013.39320 ↗
18. Dillon R C, Hiler E A Jr, Vittetoe G. Center-pivot sprinkler design based on intake characteristics. Trans ASAE, 1972, 15: 996–100110.13031/2013.38057 ↗
19. Buchleiter G W. Performance of LEPA equipment on center pivot machines. Appl Engrg Agr, 1992, 8: 631–63710.13031/2013.26135 ↗