journal article·2023-11

Fault-tolerant stator flux oriented decoupling control for dual three-phase permanent magnet motor without diagnosis and reconfiguration

LinSen Huang, WenXiang Zhao, Tao Tao, Jia Cui, Qiang Zhang

Publisher page

Abstract

In this paper, the fault-tolerant capability of the existing stator-flux-oriented decoupling control (SFOC) for the DTP-PM motor is investigated, and a simple fault-tolerant SFOC is further designed to enhance fault tolerance. Firstly, the mathematical model of the DTP-PM motor in the stator-flux-oriented rotating coordinate system is analyzed. An SFOC is proposed to guarantee healthy operation performance, considering torque, flux linkage, and harmonic currents. Secondly, the coupling relationship under open-phase conditions is assessed. The assessed result shows that the coupling relationship between the harmonic and fundamental components results in conflicts and poor post-fault operation. Thirdly, the proposed SFOC includes an automatic deactivation module to detect conflicts with a variable threshold. The conflicted harmonic current controllers can be excluded automatically. Hence, fault-tolerant control can be remedied without diagnosing the specific fault scenario, and excellent fault-tolerant capability can be achieved. Finally, experiments on a DTP-PM motor are carried out to verify the feasibility and effectiveness of the proposed strategy.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electric Motor Design and Analysis · Sensorless Control of Electric Motors · Multilevel Inverters and Converters

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (37)

Show source-provided references
1. Ryi J, Choi J S. Noise reduction effect of airfoil and small-scale rotor using serration trailing edge in a wind tunnel test. Sci China Tech Sci, 2017, 60: 325–33210.1007/s11431-016-0208-4 ↗
2. Dong Q C, Liu X T, Qi H Z, et al. Analysis and evaluation of electromagnetic vibration and noise in permanent magnet synchronous motor with rotor step skewing. Sci China Tech Sci, 2019, 62: 839–84810.1007/s11431-018-9458-5 ↗
3. Zhu S D, Zhao W X, Ji J H, et al. Design to reduce electromagnetic vibration in integral-slot SPM machine considering force modulation effect. Sci China Tech Sci, 2022, 65: 1867–187710.1007/s11431-022-2089-y ↗
4. Luo W, Wang B, Zhao H S, et al. Modeling and simulation of nonlinear dynamic process of the induction motor system with fluctuating potential loads. Sci China Tech Sci, 2014, 57: 1729–173710.1007/s11431-014-5611-4 ↗
5. Rao F, Wu X, Gao W, et al. Study on the peripheral magnetic leakage and shielding measures of surface-mounted permanent magnet motor. Chin J Electr Eng, 2022, 8: 63–6910.23919/CJEE.2022.000006 ↗
6. Zhang G, Hua W, Cheng M. Nonlinear magnetic network models for flux-switching permanent magnet machines. Sci China Tech Sci, 2016, 59: 494–50510.1007/s11431-015-5968-z ↗
7. Zeng X H, Wu Z Q, Wang Y, et al. Multi-mode energy management strategy for hydraulic hub-motor auxiliary system based on improved global optimization algorithm. Sci China Tech Sci, 2020, 63: 2082–209710.1007/s11431-019-1526-8 ↗
8. Sun Y, Zhao W, Ji J, et al. Torque improvement in dual M-phase permanent-magnet machines by phase shift for electric ship applications. IEEE Trans Veh Technol, 2020, 69: 9601–961210.1109/TVT.2020.3004161 ↗
9. Paredes J, Prieto B, Satrustegui M, et al. Improving the performance of a 1-MW induction machine by optimally shifting from a three-phase to a six-phase machine design by rearranging the coil connections. IEEE Trans Ind Electron, 2021, 68: 1035–104510.1109/TIE.2020.2969099 ↗
10. Ye D, Li J, Qu R, et al. Variable switching sequence pwm strategy of dual three-phase machine drive for high-frequency current harmonic suppression. IEEE Trans Power Electron, 2020, 35: 4984–499510.1109/TPEL.2019.2941991 ↗
11. Eldeeb H M, Abdel-Khalik A S, Hackl C M. Dynamic modeling of dual three-phase IPMSM drives with different neutral configurations. IEEE Trans Ind Electron, 2019, 66: 141–15110.1109/TIE.2018.2823684 ↗
12. Wen D, Wang W, Zhang Y. Sensorless control of permanent magnet synchronous motor in full speed range. Chin J Electr Eng, 2022, 8: 97–10710.23919/CJEE.2022.000018 ↗
13. Feng G, Lai C, Kelly M, et al. Dual three-phase PMSM torque modeling and maximum torque per peak current control through optimized harmonic current injection. IEEE Trans Ind Electron, 2019, 66: 3356–336810.1109/TIE.2018.2854550 ↗
14. Nasr A, Gu C, Wang X, et al. Torque-performance improvement for direct torque-controlled PMSM drives based on duty-ratio regulation. IEEE Trans Power Electron, 2022, 37: 749–76010.1109/TPEL.2021.3093344 ↗
15. Mavila P C, Rajeevan P P. A five-level torque controller based DTC scheme for open-end winding five-phase IM drives with single DC source and auxiliary plane harmonic elimination. IEEE Trans Ind Appl, 2022, 58: 2063–207410.1109/TIA.2022.3140361 ↗
16. Awan H A A, Hinkkanen M, Bojoi R, et al. Stator-flux-oriented control of synchronous motors: A systematic design procedure. IEEE Trans Ind Appl, 2019, 55: 4811–482010.1109/TIA.2019.2927316 ↗
17. Huang L, Tian W, Zhao W, et al. Stator-flux-oriented decoupling control strategy for dual three-phase permanent magnet motor. In: Proceedings of the 2021 IEEE 4th International Electrical and Energy Conference (CIEEC). Wuhan, 2021. 1–610.1109/CIEEC50170.2021.9510349 ↗
18. Singh G K, Iqbal A. Modeling and analysis of six-phase synchronous motor under fault condition. Chin J Electr Eng, 2017, 3: 62–7510.23919/CJEE.2017.8048413 ↗
19. Zhu Z Q, Wang S, Shao S, et al. Advances in dual-three-phase permanent magnet synchronous machines and control techniques. Energies, 2021, 14: 1–4610.3390/en14227508 ↗
20. Wang Z, Wang X, Wang Y, et al. Fault tolerant control of multiphase multilevel motor drives-technical review. Chin J Electr Eng, 2017, 3: 76–8610.23919/CJEE.2017.8048414 ↗
21. Wu B, Xu D, Ji J, et al. Field-oriented control and direct torque control for a five-phase fault-tolerant flux-switching permanent-magnet motor. Chin J Electr Eng, 2018, 4: 48–5610.23919/CJEE.2018.8606789 ↗
22. Guo H, Guo S, Xu J, et al. Power switch open-circuit fault diagnosis of six-phase fault tolerant permanent magnet synchronous motor system under normal and fault-tolerant operation conditions using the average current park’s vector approach. IEEE Trans Power Electron, 2021, 36: 2641–266010.1109/TPEL.2020.3017637 ↗
23. Saeed S, Zhao W, Wang H, et al. Fault-tolerant deadbeat model predictive current control for a five-phase PMSM with improved SVPWM. Chin J Electr Eng, 2021, 7: 111–12310.23919/CJEE.2021.000030 ↗
24. Zhang L, Zhu X, Xu L, et al. Simplified universal fault-tolerant direct torque control of FPFTPM motor with steady-healthy design under open-circuit fault. IEEE Trans Ind Electron, 2022, 69: 6688–669910.1109/TIE.2021.3100997 ↗
25. Liu T-H, Fu J-R, Lipo T A. A strategy for improving reliability of field-oriented controlled induction motor drives. IEEE Trans Ind Appl, 1993, 29: 910–91810.1109/28.245714 ↗
26. Jiang X, Huang W, Cao R, et al. Electric drive system of dual-winding fault-tolerant permanent-magnet motor for aerospace applications. IEEE Trans Ind Electron, 2015, 62: 7322–733010.1109/TIE.2015.2454483 ↗
27. Wang W, Zhang J, Cheng M, et al. Fault-tolerant control of dual three-phase permanent-magnet synchronous machine drives under open-phase faults. IEEE Trans Power Electron, 2017, 32: 2052–206310.1109/TPEL.2016.2559498 ↗
28. Hu Y, Feng Y, Li X. Fault-tolerant hybrid current control of dual three-phase PMSM with one phase open. IEEE J Emerg Sel Top Power Electron, 2022, 10: 3418–342610.1109/JESTPE.2020.3032668 ↗
29. Wang X, Wang Z, He M, et al. Fault-tolerant control of dual three-phase PMSM drives with minimized copper loss. IEEE Trans Power Electron, 2021, 36: 12938–1295310.1109/TPEL.2021.3076509 ↗
30. Sun X, Li T, Tian X, et al. Fault-tolerant operation of a six-phase permanent magnet synchronous hub motor based on model predictive current control with virtual voltage vectors. IEEE Trans Energy Convers, 2022, 37: 337–34610.1109/TEC.2021.3109869 ↗
31. Hu Y, Zhu Z Q, Wu Z. Modelling and vector control of dual three-phase PMSM with one-phase open. IET Electric Power Appl, 2021, 15: 847–86010.1049/elp2.12064 ↗
32. Wu L, Guo Y, Huang X, et al. Harmonic torque suppression methods for single-phase open-circuit fault-tolerant operation of PMSM considering third harmonic BEMF. IEEE Trans Power Electron, 2021, 36: 1116–112910.1109/TPEL.2020.3002295 ↗
33. Goncalves P F C, Cruz S M A, Mendes A M S. Online diagnostic method for the detection of high-resistance connections and open-phase faults in six-phase PMSM drives. IEEE Trans Ind Appl, 2022, 58: 345–35510.1109/TIA.2021.3120239 ↗
34. Guo H, Xu J, Chen Y H. Robust control of fault-tolerant permanentmagnet synchronous motor for aerospace application with guaranteed fault switch process. IEEE Trans Ind Electron, 2015, 62: 7309–732110.1109/TIE.2015.2453935 ↗
35. Song Z, Zhou F, Yu Y, et al. Open-phase fault-tolerant predictive control strategy for open-end-winding permanent magnet synchronous machines without postfault controller reconfiguration. IEEE Trans Ind Electron, 2021, 68: 3770–378110.1109/TIE.2020.2984975 ↗
36. Prieto I G, Duran M J, Garcia-Entrambasaguas P, et al. Field-oriented control of multiphase drives with passive fault tolerance. IEEE Trans Ind Electron, 2020, 67: 7228–723810.1109/TIE.2019.2944056 ↗
37. Wang X, Wang Z, Gu M, et al. Diagnosis-free self-healing scheme for open-circuit faults in dual three-phase PMSM drives. IEEE Trans Power Electron, 2020, 35: 12053–1207110.1109/TPEL.2020.2982324 ↗