Effect of repetitive square voltage frequency on partial discharge features
Source abstract
Abstract
The inverter-fed motor is a key component of environmental-friendly hybrid cars, high-speed trains, and other industrial applications. After the widespread use of inverter-fed motors, the repetitive impulse surges from inverters were found to cause new insulation problems in inverter-fed motors that were linked to premature insulation failure. The partial discharge (PD) induced by the overvoltage inner stator windings was found to be the root cause of insulation reliability problems. To mitigate this problem, PD detection and life testing at repetitive square voltages should be performed on new types of insulation models and entire motor insulation systems. The obtained partial discharge inception voltage (PDIV) and lifetime of insulation in the tests can be used to evaluate the insulation status of inverter-fed motor insulation systems and thus to improve the insulation designs. At AC voltage conditions, the voltage frequency can significantly affect PD activity. At repetitive square voltage with rapid rise time, the influence of the square voltage frequency on PD activity should be investigated (1) to suggest values for the repetitive square voltage frequency selection for the PDIV and lifetime tests, and (2) to increase the signal-to-noise ratio when extracting PD pulses from strong disturbances generated by the operating switch of impulse generators. Therefore, the main purpose of this paper was to investigate the effects of repetitive square voltage frequency on PD events. Insulation models of both Type I (low-voltage inverter-fed motor) and Type II (high-voltage inverter-fed motor) were used to obtain single-PD and multi-PD statistical features, respectively. Experimental results indicated that higher frequencies caused less PD events with lower PD magnitudes and shorter delay times in one square voltage cycle. This phenomenon was attributed to the different surface charge decay ratios and the initial electron emission probabilities resulting from different square voltage frequencies. Finally, a number of considerations for PD measurements on inverter-fed motors were provided to improve the sensitivity of the PD test system and to obtain high objective insulation lifetime test results, which are used to assess the insulation status of inverter-fed motors.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Electrostatic Discharge in Electronics · Lightning and Electromagnetic Phenomena
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (41)
Show source-provided references
1. Erik P. Transient effects in application of PWM inverters to induction motors. IEEE T Ind Appl, 1992, 28(5): 1095–110110.1109/28.158834 ↗
2. Kaufhold M, Borner G, Eberhardt M, et al. Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters. IEEE Electr Insul M, 1996, 12(5): 9–1610.1109/57.537190 ↗
3. Yin W. Failure mechanism of winding insulations in inverter-fed motors. IEEE Electr Insul M, 1997, 13(6): 18–2310.1109/57.637150 ↗
4. Wheeler J C G. Effects of converter pulses on the electrical insulation in low and medium voltage motors. IEEE Electr Insul M, 2005, 21(2): 22–2910.1109/MEI.2005.1412216 ↗
5. Morshuis P H F. Degradation of solid dielectrics due to internal partial discharge some thoughts on progress made and where to go now. IEEE T Dielect El In, 2005, 12(5): 905–91310.1109/TDEI.2005.1522185 ↗
6. Cecilia F, Edin H. Partial discharges in a cavity at variable applied frequency part 2 measurements and modeling. IEEE T Dielect El In, 2008, 15(6): 1610–161610.1109/TDEI.2008.4712664 ↗
7. Fabiani D, Montanari G C. The effect of voltage distortion on ageing acceleration of insulation systems under partial discharge activity. IEEE Electr Insul M, 2001, 17(3): 24–3310.1109/57.925300 ↗
8. Fenger M, Campbell S R, Pedersen J. Motor winding problems caused by inverter drives. IEEE Ind Appl Mag, 2003, 9(4): 22–3110.1109/MIA.2003.1206913 ↗
9. IEC 60034-18-41: Rotating electrical machines — Part 18–41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters, 2006
10. IEC TS 60034-18-42: Rotating electrical machines — Part 18–42: Qualification and acceptance tests for partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters, 2008
11. Tozzi M, Cavallini A, Montanari G C. Monitoring off-line and on-line PD under impulsive voltage on induction motors — part 1 standard procedure. IEEE Electr Insul M, 2010, 26(4): 16–2610.1109/MEI.2010.5511185 ↗
12. Cavallini A, Fabiani D, Montanari G C. A novel method to diagnose PWM-fed induction motors. IEEE T Dielect El In, 2008, 15(5): 1313–132110.1109/TDEI.2008.4656239 ↗
13. Fabiani D, Cavallini A, Montanari G C. A UHF technique for advanced PD measurements on inverter-fed motors. IEEE T Power Electr, 2008, 23(5): 2546–255610.1109/TPEL.2008.2002069 ↗
14. Zhou K, Wu G N, Guo X X, et al. Partial discharge activity of enameled wires under different parameters of square wave voltage. IEE J T Fund Mater, 2008, 129(12): 922–93010.1541/ieejfms.129.922 ↗
15. Elisabeth L, Tord B, Jörgen B, et al. Measurement of partial discharges at rapidly changing voltages. IEEE T Dielect El In, 2008, 15(3): 823–83110.1109/TDEI.2008.4543120 ↗
16. Guastavino F, Diadano A, Torello E. Measuring partial discharges under pulsed voltage conditions. IEEE T Dielect El In, 2008, 15(6): 1640–164810.1109/TDEI.2008.4712668 ↗
17. Cavallini A, Elisabeth L, Montanari G C, et al. Off-line PD testing of converter-fed wire-wound motors: When IEC TS 60034-18-41 may fail ? IEEE T Dielect El In, 2010, 17(5): 1385–139510.1109/TDEI.2010.5595540 ↗
18. Marco T, Cavallini A, Carlo M G. Monitoring off-line and on-line PD under impulsive voltage on induction motors — Part 2 testing. IEEE Electr Insul M, 2011, 27(1): 14–3110.1109/MEI.2011.5699443 ↗
19. Nyamupangedengu C. Time-varying partial discharge spectral characteristics in solid polymer insulation. IET Sci Meas Technol, 2012, 6(2): 85–9510.1049/iet-smt.2011.0052 ↗
20. Illias H A, George C, Lewin P L. Partial discharge behavior within a spherical cavity in a solid dielectric material as a function of frequency and amplitude of the applied voltage. IEEE T Dielect El In, 2011, 18(2): 433–44310.1109/TDEI.2011.5739447 ↗
21. Cavallini A, Montanari G C. Effect of supply voltage frequency on testing of insulation system. IEEE T Dielect El In, 2006, 13(1): 111–12110.1109/TDEI.2006.1593409 ↗
22. Cecilia F, Edin H. Partial discharges in a cavity at variable applied frequency part 1 measurements. IEEE T Dielect El In, 2008, 15(6): 1601–160910.1109/TDEI.2008.4712663 ↗
23. Nyamupangedengu C, Jandrell I R. Partial discharge spectral response to variations in the supply voltage frequency. IEEE T Dielect El In, 2012, 19(2): 521–53210.1109/TDEI.2012.6180246 ↗
24. Stranges M K W, Stone G C, Bogh D L. Voltage endurance testing. IEEE Ind Appl Mag, 2009, 15(6): 12–1810.1109/MIAS.2009.934439 ↗
25. Wang P, Cavallini A, Montanari G C, et al. Effect of rise time on PD pulse features under repetitive square wave voltages. IEEE T Dielect El In, 2013, 20(1): 245–25410.1109/TDEI.2013.6451364 ↗
26. Hayakawa N, Okubo H. Feature article-lifetime characteristics of nanocomposite enameled wire under surge voltage application. IEEE Electr Insul M, 2008, 24(2): 22–2710.1109/MEI.2008.4473051 ↗
27. Wang P, Wu G N, Gao B, et al. Study of partial discharge characteristics at repetitive square voltages based on UHF method. Sci China Tech Sci, 2013, 56(1): 262–27010.1007/s11431-012-5040-1 ↗
28. Okubo H, Hayakawa N, Montanari G C. Technical development on partial discharge measurement and electrical insulation techniques for low voltage motors driven by voltage inverters. IEEE T Dielect El In, 2007, 14(6): 1516–153010.1109/TDEI.2007.4401236 ↗
29. Illias H A, Chen G, Lewin P L. Partial discharge behavior within a spherical cavity in a solid dielectric material as a function of frequency and amplitude of the applied voltage. IEEE T Dielect El In, 2011, 18(2): 433–44310.1109/TDEI.2011.5739447 ↗
30. Hudon C, Bélec M. Partial discharge signal interpretation for generator diagnostics. IEEE T Dielect El In, 2005, 12(2): 297–31910.1109/TDEI.2005.1430399 ↗
31. Gulski E. Digital analysis of partial discharges. IEEE T Dielect El In, 1995, 2(5): 822–83710.1109/94.469977 ↗
32. Morshuis P H F, Smit J. Partial discharges at dc voltage their mechanism, detection and analysis. IEEE T Dielect El In, 2005, 12(2): 328–34010.1109/TDEI.2005.1430401 ↗
33. Cavallini A, Montanari G C, Tozzi M, et al. Diagnostic of HVDC systems using partial discharges. IEEE T Dielect El In, 2011, 18(1): 275–28410.1109/TDEI.2011.5704519 ↗
34. Fabiani D, Montanari G C, Cavallini A, et al. Relation between space charge accumulation and partial discharge activity in enameled wires under PWM-like voltage waveforms. IEEE T Dielect El In, 2004, 11(3): 393–40510.1109/TDEI.2004.1306718 ↗
35. Brunt R J V, Cernyar E W. Importance of unraveling memory propagation effects in interpreting data on partial discharge statistics. IEEE T Dielect El In, 1993, 28(6): 905–915
36. Niemeyer L. A generalized approach to partial discharge modeling. IEEE T Dielect El In, 1995, 2(4): 510–52810.1109/94.407017 ↗
37. Cecilia F, Edin H. Partial discharges in a cavity at variable applied frequency part 2 measurements and modeling. IEEE T Dielect El In, 2008, 15(6): 1610–161610.1109/TDEI.2008.4712664 ↗
38. Gutfleisch F, Niemeyer L. Measurement and simulation of PD in epoxy voids. IEEE T Dielect El In, 1995, 2(5): 729–74310.1109/94.469970 ↗
39. Bartnikas R, Novak J P. Effect of overvoltage on the risetime and amplitude of PD pulses. IEEE T Dielect El In, 1995, 2(4): 557–56610.1109/94.407021 ↗
40. Morshuis P H F, Kreuger F H. Partial Discharge Mechanism: Mechanisms Leading to Breakdown, Analysed by Fast Electrical and Optical Measurements. Delft: Delft University Press, 1993
41. Naoki H, Iroshi I, Yusuke N, et al. Time variation of partial discharge activity leading to breakdown of magnet wire under repetitive surge voltage application. IEEE T Dielect El In, 2008, 15(6): 1701–170610.1109/TDEI.2008.4712674 ↗