journal article·2013-01

Study of partial discharge characteristics at repetitive square voltages based on UHF method

Peng Wang, GuangNing Wu, Bo Gao, Yang Luo, KaiJiang Cao

Publisher page

Abstract

Due to overvoltage produced by inverter output, inverter-fed motor insulation systems often experience fast electrical aging process, especially when partial discharge (PD) is incepted. Before putting into use, the PD detection should be performed on inverter-fed motors at repetitive square voltages to avoid the PD caused insulation deterioration when the motors are collected to inverters having specific characteristics. However, unlike PD tests at AC/DC voltages proposed in IEC 60270, the PD detection at repetitive square voltages is much more complex because of serious interference generated by impulse generator. To solve the problem, ultra-high frequency (UHF) method seems recommendable for its preferable signal-to-noise ratio (SNR). The chief aim of this study is to investigate PD pulse and statistical characteristics of turn-to-turn insulation for inverter-fed traction motors. A square-shaped Archimedes antenna, specially designed for the PD detection at repetitive square voltages of fast rise times, was used to perform PD tests on turn-to-turn insulation models. Time and frequency analysis results indicate that energy component of generator disturbance and PD pulses are mainly distributed in the 0–0.5 GHz and 0.6–1.5 GHz range, respectively. Based on the results, suitable filter was designed for power disturbance suppression. Additionally, resorting to the sensor unit (i.e. antenna and filter) and the PD test system, the PD statistical features at square voltages of different frequencies were obtained. Experimental results show that higher frequency will give rise, statistically, to PD of lower magnitudes distributing at smaller phases. A reasonable interpretation of this phenomenon was presented. Lastly, according to the PD statistical features, some suggestions for the PD detection system design, generator parameter optimization and the PD pulse extracting were given. The results of this work would be beneficial to the increase of the sensitivity when performing the PD detection on insulation systems for inverter-fed motors at repetitive square voltages and thus, improving the reliability of inverter-fed motors.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: High voltage insulation and dielectric phenomena · Dielectric materials and actuators · Electrostatic Discharge in Electronics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. Erik P. Transient effects in application of PWM inverters to induction motors. IEEE T Ind Appl, 1992, 28(5): 1095–110110.1109/28.158834 ↗
2. Stone G C, Heeswijk R G, Bartnikas R. Investigation of the effect of repetitive voltage surges on epoxy insulation. IEEE T Energy Conver, 1992, 7(4): 754–76010.1109/60.182659 ↗
3. Wheeler J C G. Effects of converter pulses on the electrical insulation in low and medium voltage motors. IEEE Electr Insul M, 2005, 21(2): 22–2910.1109/MEI.2005.1412216 ↗
4. Yin W J. Failure mechanism of winding insulations in inverter-fed motors. IEEE Electr Insul M, 1997, 13(6): 18–2310.1109/57.637150 ↗
5. Zhou K, Wu G N, Guo X X, et al. Partial discharge activity of enameled wires under different parameters of square wave voltage. IEE J T Fund Mater, 2008, 129(12): 922–93010.1541/ieejfms.129.922 ↗
6. Hayakawa N, Morikawa M, Okubo H. Partial discharge inception and propagation characteristics of magnet wire for inverter-fed motor under surge voltage application. IEEE T Dielect El In, 2007, 14(1): 39–4510.1109/TDEI.2007.302870 ↗
7. Tozzi M, Cavallini A, Montanari G C. Monitoring off-line and on-line PD under impulsive voltage on induction motors—Part 1: Standard procedure. IEEE Electr Insul M, 2010, 26(4): 16–2610.1109/MEI.2010.5511185 ↗
8. Hayakawa N, Shimizu F, Okubo H. Estimation of partial discharge inception voltage of magnet wires under inverter surge voltage by volume-time theory. IEEE T Dielect El In, 2012, 19(2): 550–55710.1109/TDEI.2012.6180249 ↗
9. Zhou L R, Wu G N, Gao B, et al. Study on charge transport mechanism and space charge characteristics of polyimide films. IEEE T Dielect El In, 2009, 16(4): 1143–114910.1109/TDEI.2009.5211868 ↗
10. Kaufhold M, Borner G, Eberhardt M, et al. Failure mechanism of the interturn insulation of low voltage electric machines fed by pulsecontrolled inverters. IEEE Electr Insul M, 1996, 12(5): 9–1610.1109/57.537190 ↗
11. IEC 60034-18-41: Rotating electrical machines—Part 18-41: Qualification and type tests for Type I electrical insulation systems used in rotating electrical machines fed from voltage converters, 2006
12. IEC TS 60034-18-42: Rotating electrical machines—Part 18-42: Qualification and acceptance tests for partial discharge resistant electrical insulation systems (Type II) used in rotating electrical machines fed from voltage converters, 2008
13. Fabiani D, Cavallini A, Montanari G C. A UHF technique for advanced PD measurements on inverter-fed motors. IEEE T Power Electr, 2008, 23(5): 2546–255610.1109/TPEL.2008.2002069 ↗
14. Lindell E, Bengtsson T, Blennow J, et al. Evaluation of a PD measuring system for repetitive steep voltage waveforms. IEEE T Dielect El In, 2011, 18(1): 246–25510.1109/TDEI.2011.5704516 ↗
15. Guastavino F, Diadano A, Torello E. Measuring partial discharges under pulsed voltage conditions. IEEE T Dielect El In, 2008, 15(6): 1640–164810.1109/TDEI.2008.4712668 ↗
16. Lindell E, Bengtsson T, Blennow J, et al. Influence of rise time on partial discharge extinction voltage at semi-square voltage waveforms. IEEE T Dielect El In, 2010, 17(1): 141–14810.1109/TDEI.2010.5412012 ↗
17. Kimura K, Ushirone S, Koyanagi T, et al. PDIV characteristics of twisted-pair of magnet wires with repetitive impulse voltage. IEEE T Dielect El In, 2007, 14(3): 744–75010.1109/TDEI.2007.369539 ↗
18. Florkowska B, Roehrich J, Zydroń P, et al. Measurement and analysis of surface partial discharges at semi-square voltage waveforms. IEEE T Dielect El In, 2011, 18(4): 990–9610.1109/TDEI.2011.5976086 ↗
19. Nyamupangedengu C, Jandrell I R. Partial discharge spectral response to variations in the supply voltage frequency. IEEE T Dielect El In, 2012, 19(2): 521–3210.1109/TDEI.2012.6180246 ↗
20. Hammarström T, Bengtsson T, Blennow J, et al. Evidence for changing PD properties at short voltage rise times. IEEE T Dielect El In, 2011, 18(5): 1686–169210.1109/TDEI.2011.6032840 ↗
21. Nyamupangedengu C. Time-varying partial discharge spectral characteristics in solid polymer insulation. IET Sci Meas Technol, 2012, 6(2): 85–9510.1049/iet-smt.2011.0052 ↗
22. Niemeyer L. A generalized approach to partial discharge modeling. IEEE T Dielect El In, 1995, 2(4): 510–52810.1109/94.407017 ↗
23. Gutfleisch F, Niemeyer L. Measurement and simulation of PD in epoxy voids. IEEE T Dielect El In, 1995, 2(5): 729–74310.1109/94.469970 ↗
24. Montanari G C. Bringing an insulation to failure: the role of space charge. IEEE T Dielect El In, 2011, 18(2): 339–36310.1109/TDEI.2011.5739438 ↗
25. Illias H A, Chen G, Lewin P L. Partial discharge behavior within a spherical cavity in a solid dielectric material as a function of frequency and amplitude of the applied voltage. IEEE T Dielect El In, 2011, 18(2): 433–44310.1109/TDEI.2011.5739447 ↗