Tempospacial energy-saving effect-based diagnosis in large coal-fired power units: Energy-saving benchmark state
Source abstract
Abstract
The energy-saving analytics of coal-fired power units in China is confronting new challenges especially with even more complicated system structure, higher working medium parameters, time-dependent varying operation conditions and boundaries such as load rate, coal quality, ambient temperature and humidity. Compared with the traditional optimization of specific operating parameters, the idea of the energy-consumption benchmark state was proposed. The equivalent specific fuel consumption (ESFC) analytics was introduced to determine the energy-consumption benchmark state, with the minimum ESFC under varying operation boundaries. Models for the energy-consumption benchmark state were established, and the endogenous additional specific consumption (ASFC) and exogenous ASFC were calculated. By comparing the benchmark state with the actual state, the energy-saving tempospacial effect can be quantified. As a case study, the energy consumption model of a 1000 MW ultra supercritical power unit was built. The results show that system energy consumption can be mainly reduced by improving the performance of turbine subsystem. This nearly doubles the resultant by improving the boiler system. The energy saving effect of each component increases with the decrease of load and has a greater influence under a lower load rate. The heat and mass transfer process takes priority in energy saving diagnosis of related components and processes. This makes great reference for the design and operation optimization of coal-fired power units.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Process Optimization and Integration · Thermodynamic and Exergetic Analyses of Power and Cooling Systems · Advanced Control Systems Optimization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. China Electricity Council. Annual Devel Opment Report of China’s Power Industry. Beijing: China Market Press, 2014
2. Valero A, Correas L, Zaleta A, et al. On the thermoeconomic approach to the diagnosis of energy system malfunctions part 1: The TADEUS problem. Energy, 2004, 29: 1875–188710.1016/j.energy.2004.04.053 ↗
3. Valero A, Correas L, Zaleta A, et al. On the thermoeconomic approach to the diagnosis of energy system malfunctions part 2: Malfunction definitions and assessment. Energy, 2004, 29: 1889–190710.1016/j.energy.2004.03.008 ↗
4. Jiang X L, Liu P, Li Z. Data reconciliation and gross error detection for operational data in power plants. Energy, 2014, 75: 14–2310.1016/j.energy.2014.03.024 ↗
5. Si F Q, Gu H, Ye Y L, et al. Online unit load economic dispatch based on chaotic-particle swarm optimization algorithm (in Chinese). P CSEE, 2011, 31: 103–109
6. Chen D G, Zhang W X. The random set expression of pawlak rough set model and its composition (in Chinese). Comput Sci, 2002, 29: 18–19
7. Jiang F, Wang P H. Arithmetic research of local quantitative modificatory model on equivalent enthalpy drop (in Chinese). Turb Techno, 2008, 50: 122–125
8. Chen H P, Zhang S F, Zhang C F, et al. Coal-fired power plant thermal system heat unit matrix analysis method (in Chinese). Power Eng, 1992, 19: 38–40
9. Yan S L, Hu S G, Xu H, et al. Research on the unified physical model and mathematic model of heat-economic analysis for the coal-fired power unit (in Chinese). P CSEE, 2008, 28:37–40
10. Li Y, Cao L H, Lin W B. Improvements on the equivalent enthalpy drop method (in Chinese). P CSEE, 2004, 24: 243–247
11. Zhang C F, Zhang S X, Cui Y H, et al. Thermo-economy state equation of modern power system (in Chinese). J Eng Thermophys, 2001, 22: 665–667
12. Uson S, Valero A. Thermoeconomic diagnosis for improving the operation of energy intensive systems: Comparison of methods. Appl Energ, 2011, 88: 699–71110.1016/j.apenergy.2010.09.010 ↗
13. Bejan A, Tsatsaronis G, Moran M. Thermal Design and Optimization. New York: John Wiley & Sons, 1996
14. Song Z P. The theory and implementation of energy specific fuel consumption (in Chinese). P CSEE, 1992, 12: 15–21
15. Guo J L, Zhang S F, Song Z P, et al. A matrix method for thermal system analysis in a power plant (in Chinese). P CSEE, 2004, 24: 205–210
16. Lazzaretto A, Tsatsaronis G. Speco: A systematic and general methodology for calculating efficiencies and costs in thermal systems. Energy, 2006, 31: 1257–128910.1016/j.energy.2005.03.011 ↗
17. Tsatsaronis G. Design optimization using exergoeconomics. Thermodynamic Optimization of Complex Energy Systems. Netherlands: Kluwer Academic Publishers, 1999
18. Yang Y P, Yang K. Theory of energy conservation potential diagnosis for a coal-fired unit and its application (in Chinese). P CSEE, 1998, 18: 131–134
19. Chang H, Chuang S C. Process analysis using the concept of intrinsic and extrinsic exergy losses. Energy, 2003, 28: 1203–122810.1016/S0360-5442(03)00116-6 ↗
20. Chang H, Li J W. A new exergy method for process analysis and optimization. Chem Eng Sci, 2005, 60: 2771–278410.1016/j.ces.2004.12.029 ↗
21. Yang Y P, Wang L G, Dong C Q, et al. Comprehensive exergy-based evaluation and parametric study of a coal-fired ultra-supercritical power plant. Appl Energ, 2013, 112: 1087–109910.1016/j.apenergy.2012.12.063 ↗
22. Valero A, Lerch F, Serra L, et al. Structural theory and thermoeconomic diagnosis. Part II: Application to an actual power plant. Energ Convers Manage, 2002, 43: 1519–1535
23. Toffolo A, Lazzaretto A. A new thermoeconomic method for the location of causes of malfunctions in energy systems. J Energ Resour-ASME, 2006, 129, 1–910.1115/1.2424960 ↗
24. Song Z P. A case study of unit consumption analysis (in Chinese). J Eng Thermophys, 1996, 17: 397–399
25. Yang Y P, Guo X Y, Wang N L. Power generation from pulverized coal in China. Energy, 2010, 35: 4336–434810.1016/j.energy.2009.05.006 ↗
26. Wang N L, Yang Z P, Wu Y. Energy-saving evaluation and system optimization for large coal-fired power units (in Chinese). J Ncepu, 2010, 37: 55–58
27. Xing Z Z. Technology research on depth peak load cycling of thermal power generator units (in Chinese). Dissertation of Master Degree. Beijing: North China Electric Power University, 2013
28. Li P Y. The lowest stable-combustion research of a 1000 MW ultra supercritical boiler (in Chinese). Guangdong Sci Tech, 2013, 22: 40–41
29. Tang P, Li Y Y, Li G T, et al. The unit selection of 600 MW pithead power plant (in Chinese). Boiler Tech, 2013, 44: 10–14
30. Yin X, Zheng J F, He B S, et al. Effect of temperature and volatile-char interactions on ratio of volatile-NO and char-NO during coal combustion (in Chinese). Boiler Tech, 2013, 44: 61–63
31. Tian J J. Circulating water system optimization analysis during the operation of steam turbine and condenser (in Chinese). Sci Tech Vision, 2013, 3: 60–61
32. Hu F M, Xi J B. The operation optimization of the condenser circulating water in power plant (in Chinese). Yunnan Electric Power, 2013, 41: 84–86
33. Cang G C, Wu H J, Wang L, et al. The study of method for boiler optimized operation oxygen (in Chinese). Boiler Tech, 2008, 39: 622–624
34. Wang N L, Yang Y P, Yang Z P, et al. Energy-consumption benchmark diagnosis of thermal power units under varying operation boundary (in Chinese). P CSEE, 2013, 33: 1–7
35. Fu P, Wang N L, Yang Y P, et al. The mechanism of energyconsumption benchmark in coal-fired units with varying boundary (in Chinese). J Eng Thermophys, 2015, 36: 468–473
36. Tsatsaronis G, Morosuk T. A general exergy-based method for combining a cost analysis with an environmental impact analysis. Part I: Theoretical development. In: ASME Conference Proceedings, 2008, 8: 453–462
37. Toffolo A, Lazzaretto A. On the thermoeconomic approach to the diagnosis of energy system malfunctions. Indicators to diagnose malfunctions: Application of a new indicator for the location of causes. Int J Thermodyn, 2004, 7: 41–49