journal article·2013-04

Cell trapping and patterning using dielectric-structure-assisted negative dieletrophoresis

Hua Dang, YingTao Ding, ZheYao Wang

Publisher page

Abstract

This paper reports a cell trapping and patterning method using dielectric-pattern-assisted negative dielectrophoresis (dnDEP) that can achieve high-density cell arrays and complicated cell patterns. The dnDEP device consists of two planar metal electrodes and a patterned dielectric layer sandwiched in-between. The dielectric patterns generate non-uniform electric fields when an ac voltage is applied on the two electrodes, and the interaction of polarizable cells and the non-uniform electric fields imposes negative DEP forces on the cells, pushing them to the patterns in the dielectric layer. Using this dnDEP device, human lymphoma cells were successfully patterned in high-density microwell arrays and stellate structures. Thanks to the three-dimensional configuration and the small distance between the electrodes, cell trapping and patterning can be implemented with a voltage of 10 V. This dnDEP device has the advantages of simple configuration, low actuating voltage, and the compatibility with high conductivity physiological media for cell culturing.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Microfluidic and Bio-sensing Technologies · Electrical and Bioimpedance Tomography · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Khademhosseini A, Langer R, Borenstein J, et al. Microscale technologies for tissue engineering and biology. Proc Natl Acad Sci USA, 2006, 103: 2480–248710.1073/pnas.0507681102 ↗
2. Nahmias Y, Odde D J. Micropatterning of living cells by laser-guided direct writing: Application to fabrication of hepatic-endothelial sinusoid-like structures. Nat Protoc, 2006, 1: 2288–229610.1038/nprot.2006.386 ↗
3. Azioune A, Storch M, Bornens M, et al. Simple and rapid process for single cell micro-patterning. Lab Chip, 2009, 9: 1640–164210.1039/b821581m ↗
4. Fukuda J, Khademhosseini A, Yeh J, et al. Micropatterned cell co-cultures using layer-by-layer deposition of extracellular matrix components. Biomaterials, 2006, 27: 1479–148610.1016/j.biomaterials.2005.09.015 ↗
5. Kane R S, Takayama S, Ostuni E, et al. Patterning proteins and cells using soft lithography. Biomaterials, 2009, 20: 2363–237610.1016/S0142-9612(99)00165-9 ↗
6. Mirsaidov U, Scrimgeour J, Timp W, et al. Live cell lithography: Using optical tweezers to create synthetic tissue. Lab Chip, 2008, 8: 2174–218110.1039/b807987k ↗
7. Akiyama H, Ito A, Kawabe Y, et al. Fabrication of complex three-dimensional tissue architectures using a magnetic force-based cell patterning technique. Biomed Microdevices, 2009, 11: 713–72110.1007/s10544-009-9284-x ↗
8. Shi J, Ahmed D, Mao X, et al. Acoustic tweezers: Patterning cells and microparticles using standing surface acoustic waves (SSAW). Lab Chip, 2009, 9: 2890–289510.1039/b910595f ↗
9. Ding Y T, Wang J P, Wang Z Y, et al. Numerical simulation and optimization of insulator-based dielectrophoresis devices for biopartical separation (in Chinese). Chin J Sens Actuators, 2007, 20(1): 50–53
10. Kang Y, Li D. Electrokinetic motion of particles and cells in microchannels. Microfluid Nanofluid, 2009, 6: 431–46010.1007/s10404-009-0408-7 ↗
11. Ni Z H, Yi H, Zhu S C, et al. Research on critical technology of micro/nano bioparticles manipulation platform based on light-induced dielectrophoresis. Sci China Ser E-Tech Sci, 2009, 52(10): 2831–283910.1007/s11431-009-0104-6 ↗
12. Park K, Suk H J, Akin D, et al. Dielectrophoresis-based cell manipulation using electrodes on a reusable printed circuit board. Lab Chip, 2009, 9: 2224–222910.1039/b904328d ↗
13. Sebastian A, Buckle A M, Markx G H. Formation of multilayer aggregates of mammalian cells by dielectrophoresis. J Micromech Microeng, 2006, 16: 1769–177710.1088/0960-1317/16/9/003 ↗
14. Becker F F, Wang X B, Huang Y, et al. The removal of human leukemia-cells from blood using integrated microelectrodes. J Phys D-Appl Phys, 1994, 27: 2659–266210.1088/0022-3727/27/12/030 ↗
15. Gallo-Villanueva R C, Perez-Gonzalez V H, Davalos R V, et al. Separation of mixtures of particles in a multipart microdevice employing insulator-based dielectrophoresis. Electrophoresis, 2011, 32(18): 2456–246510.1002/elps.201100174 ↗
16. Gray D S, Tan J L, Voldman J, et al. Dielectrophoretic registration of living cells to a microelectrode array. Biosens Bioelectron, 2004, 19: 771–78010.1016/j.bios.2003.08.013 ↗
17. Muller T, Pfennig A, Klein P, et al. The potential of dielectrophoresis for single-cell experiments. IEEE Eng Med Biol Mag, 2003, 22: 51–6110.1109/MEMB.2003.1266047 ↗
18. Mittal N, Rosenthal A, Voldman J. nDEP microwells for single-cell patterning in physiological media. Lab Chip, 2007, 7: 1146–115310.1039/b706342c ↗
19. Matsue T, Matsumoto N, Uchida I. Rapid micropatterning of living cells by repulsive dielectrophoretic force. Electrochim Acta, 1997, 42: 3251–325610.1016/S0013-4686(97)00175-8 ↗
20. Thomas R S, Morgan H, Green N G. Negative DEP traps for single cell immobilization. Lab Chip, 2009, 9: 1534–154010.1039/b819267g ↗
21. Suzuki M, Yasukawa T, Shiku H, et al. Negative dielectrophoretic patterning with different cell types. Biosens Bioelectron, 2008, 24: 1043–104710.1016/j.bios.2008.06.051 ↗
22. Ino K, Shiku H, Ozawa F, et al. Manipulation of microparticles for construction of array patterns by negative dielectrophoresis using multilayered array and grid electrodes. Biotechnol Bioeng, 2009, 104: 709–71810.1002/bit.22445 ↗
23. Iliescu C, Yu L, Tay F E H, et al. Bidirectional field-flow particle separation method in a dielectrophoretic chip with 3D electrodes. Sens Actuators B, 2008, 129: 491–49610.1016/j.snb.2007.11.023 ↗
24. Lapizco-Encinas B H, Ozuna-Chacon S, Rito-Palomares M. Protein manipulation with insulator-based dielectrophoresis and direct current electric fields. J Chromatogr A, 2008, 1206: 45–5110.1016/j.chroma.2008.05.077 ↗
25. Moncada-Hernandez H, Lapizco-Encinas B H. Simultaneous concentration and separation of microorganisms: Insulator-based dielectrophoretic approach. Anal Bioanal Chem, 2010, 396(5): 1805–181610.1007/s00216-009-3422-4 ↗
26. Bhattacharya S, Chao T C, Ros A. Insulator-based dielectrophoretic single particle and single cancer cell trapping. Electrophoresis, 2011, 32(8): 2550–255810.1002/elps.201100066 ↗
27. Moncada-Hernandez H, Baylon-Cardiel J L, Perez-Gonzalez V H, et al. Insulator-based dielectrophoresis of microorganisms: Theoretical and experimental results. Electrophoresis, 2011, 32(18): 2502–251110.1002/elps.201100168 ↗
28. Sabounchi P, Morales A M, Ponce P, et al. Sample concentration and impedance detection on a microfluidic polymer chip. Biomed Microdevices, 2008, 10: 661–67010.1007/s10544-008-9177-4 ↗
29. Demierre N, Braschler T, Muller R, et al. Focusing and continuous separation of cells in a microfluidic device using lateral dielectrophoresis. Sens Actuators B, 2008, 132: 388–39610.1016/j.snb.2007.09.078 ↗
30. Jen C P, Chen T W. Selective trapping of live and dead mammalian cells using insulator-based dielectrophoresis within open-top microstructures. Biomed Microdevices, 2009, 11: 597–60710.1007/s10544-008-9269-1 ↗
31. Jones T B. Electromechanics of Particle. Cambridge, U.K.: Cambridge University Press, 199510.1017/CBO9780511574498 ↗
32. Kotzar G, Freas M, Abel P, et al. Evaluation of MEMS materials of construction for implantable medical devices. Biomaterials, 2002, 23: 2737–275010.1016/S0142-9612(02)00007-8 ↗
33. Chin V I, Taupin P, Sanga S, et al. Microfabricated platform for studying stem cell fates. Biotechnol Bioeng, 2004, 88: 399–41510.1002/bit.20254 ↗
34. Wang L, Wu Z Z, Xu B, et al. SU-8 microstructure for quasi-three-dimensional cell-based biosensing. Sens Actuators B, 2009, 140: 349–35510.1016/j.snb.2009.05.009 ↗
35. Rettig J R, Folch A. Large-scale single-cell trapping and imaging using microwell arrays. Anal Chem, 2005, 77: 5628–563410.1021/ac0505977 ↗