journal article·2017-11

Performance analysis of microcantilever array sensing

XiaRong Zhou, Hong Liu, ShangQuan Wu, QingChuan Zhang, XiaoPing Wu

Publisher page

Abstract

Array sensing is increasingly important in the development of microcantilever (MC) sensors, and response consistency is the foundation for MC array sensing. In the present work, we investigated the response consistency of MC array sensing. The responses of two types of commercially available MC arrays were studied under conditions of temperature change, solution replacement and biochemical molecular interaction. For the thermal response, the deflections of both arrays were found to be proportional to temperature, and the responses of the MCs in both arrays were consistent with each other. The thermal response sensitivity for each MC during temperature increase and decrease also showed good consistency. Moreover, the MC array showed good consistency for the response induced by solution replacement. Finally, we also demonstrated that the MC array had good consistency in biochemical detection, exemplified by aflatoxin antibody-antigen binding. The good response consistency makes this technology reliable and accurate for biochemical sensing.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Mechanical and Optical Resonators · Force Microscopy Techniques and Applications · Acoustic Wave Resonator Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (31)

Show source-provided references
1. Gimzewski J K, Gerber C, Meyer E, et al. Observation of a chemical reaction using a micromechanical sensor. Chem Phys Lett, 1994, 217: 589–59410.1016/0009-2614(93)E1419-H ↗
2. Pinnaduwage L A, Gehl A, Hedden D L, et al. Explosives: A microsensor for trinitrotoluene vapour. Nature, 2003, 425: 474–47410.1038/425474a ↗
3. Lee D, Jin Y, Jung N, et al. Gravimetric analysis of the adsorption and desorption of CO2 on amine-functionalized mesoporous silica mounted on a microcantilever array. Environ Sci Technol, 2011, 45: 5704–570910.1021/es200680v ↗
4. Patton J F, Hunter S R, Sepaniak M J, et al. Rapid response microsensor for hydrogen detection using nanostructured palladium films. Sensors Actuators A-Phys, 2010, 163: 464–47010.1016/j.sna.2010.08.025 ↗
5. Dutta P, Chapman P J, Datskos P G, et al. Characterization of ligandfunctionalized microcantilevers for metal ion sensing. Anal Chem, 2005, 77: 6601–660810.1021/ac051082i ↗
6. Chapman P J, Long Z, Datskos P G, et al. Differentially ligand-functionalized microcantilever arrays for metal ion identification and sensing. Anal Chem, 2007, 79: 7062–706810.1021/ac070754x ↗
7. Huang L S, Pheanpanitporn Y, Yen Y K, et al. Detection of the antiepileptic drug phenytoin using a single free-standing piezoresistive microcantilever for therapeutic drug monitoring. Biosens Bioelectron, 2014, 59: 233–23810.1016/j.bios.2014.03.047 ↗
8. Hou H, Bai X, Xing C, et al. Aptamer-based cantilever array sensors for oxytetracycline detection. Anal Chem, 2013, 85: 2010–201410.1021/ac3037574 ↗
9. Bai X, Hou H, Zhang B, et al. Label-free detection of kanamycin using aptamer-based cantilever array sensor. Biosens Bioelectron, 2014, 56: 112–11610.1016/j.bios.2013.12.068 ↗
10. Fritz J. Translating biomolecular recognition into nanomechanics. Science, 2000, 288: 316–31810.1126/science.288.5464.316 ↗
11. Zhang J, Lang H P, Yoshikawa G, et al. Optimization of DNA hybridization efficiency by pH-driven nanomechanical bending. Langmuir, 2012, 28: 6494–650110.1021/la205066h ↗
12. Domínguez C M, Kosaka P M, Mokry G, et al. Hydration induced stress on dna monolayers grafted on microcantilevers. Langmuir, 2014, 30: 10962–1096910.1021/la501865h ↗
13. Wu G, Datar R H, Hansen K M, et al. Bioassay of prostate-specific antigen (PSA) using microcantilevers. Nat Biotechnol, 2001, 19: 856–86010.1038/nbt0901-856 ↗
14. Buchapudi K, Xu X, Ataian Y, et al. Micromechanical measurement of AChBP binding for label-free drug discovery. Analyst, 2012, 137: 263–26810.1039/C1AN15734E ↗
15. Federici S, Oliviero G, Hamad-Schifferli K, et al. Protein thin film machines. Nanoscale, 2010, 2: 2570–257410.1039/c0nr00616e ↗
16. Mader A, Gruber K, Castelli R, et al. Discrimination of escherichia coli strains using glycan cantilever array sensors. Nano Lett, 2012, 12: 420–42310.1021/nl203736u ↗
17. Wang J, Morton M J, Elliott C T, et al. Rapid detection of pathogenic bacteria and screening of phage-derived peptides using microcantilevers. Anal Chem, 2014, 86: 1671–167810.1021/ac403437x ↗
18. Maloney N, Lukacs G, Jensen J, et al. Nanomechanical sensors for single microbial cell growth monitoring. Nanoscale, 2014, 6: 8242–824910.1039/C4NR01610F ↗
19. Tan W, Huang Y, Nan T, et al. Development of protein a functionalized microcantilever immunosensors for the analyses of small molecules at parts per trillion levels. Anal Chem, 2010, 82: 615–62010.1021/ac901937g ↗
20. Zhao H, Xue C, Nan T, et al. Detection of copper ions using microcantilever immunosensors and enzyme-linked immunosorbent assay. Anal Chim Acta, 2010, 676: 81–8610.1016/j.aca.2010.07.041 ↗
21. Xue C, Zhao H, liu H, et al. Development of sulfhydrylated antibody functionalized microcantilever immunosensor for taxol. Sensors Actuators B-Chem, 2011, 156: 863–86610.1016/j.snb.2011.02.055 ↗
22. Nan T, Wu S, Zhao H, et al. Development of a secondary antibody thio-functionalized microcantilever immunosensor and an elisa for measuring ginsenoside re content in the herb ginseng. Anal Chem, 2012, 84: 4327–433310.1021/ac203414z ↗
23. Wu S, Liu H, Cheng T, et al. Highly sensitive nanomechanical assay for the stress transmission of carbon chain. Sensors Actuators B-Chem, 2013, 186: 353–35910.1016/j.snb.2013.06.035 ↗
24. Wu S, Nan T, Xue C, et al. Mechanism and enhancement of the surface stress caused by a small-molecule antigen and antibody binding. Biosens Bioelectron, 2013, 48: 67–7410.1016/j.bios.2013.03.086 ↗
25. van den Hurk R, Evoy S. Deflection cantilever detection of interferon gamma. Sensors Actuators B-Chem, 2013, 176: 960–96510.1016/j.snb.2012.09.023 ↗
26. Oliviero G, Chiari M, De Lorenzi E, et al. Leveraging on nanomechanical sensors to single out active small ligands for β2-microglobulin. Sensors Actuators B-Chem, 2013, 176: 1026–103110.1016/j.snb.2012.09.032 ↗
27. Barnes J R, Stephenson R J, Woodburn C N, et al. A femtojoule calorimeter using micromechanical sensors. Rev Sci Instruments, 1994, 65: 3793–379810.1063/1.1144509 ↗
28. Wu L, Cheng T, Zhang Q C. A bi-material microcantilever temperature sensor based on optical readout. Measurement, 2012, 45: 1801–180610.1016/j.measurement.2012.04.003 ↗
29. Zhang Y, Ren Q, Zhao Y. Modelling analysis of surface stress on a rectangular cantilever beam. J Phys D-Appl Phys, 2004, 37: 2140–214510.1088/0022-3727/37/15/014 ↗
30. Huang Y, Liu H, Li K, et al. The influence of refractive index change on a micro-cantilever bio/chemical sensor system based on optical lever read-out method. Sensors Actuators A-Phys, 2008, 148: 329–33410.1016/j.sna.2008.08.011 ↗
31. Miraglia M, Brera C, Colatosti M. Application of biomarkers to assessment of risk to human health from exposure to mycotoxins. MicroChem J, 1996, 54: 472–47710.1006/mchj.1996.0124 ↗