Fatigue failure of ferroelectric ceramics subjected to cyclic inclined electric loading
Source abstract
Abstract
Abstract Experimental tests were carried out on a series of ferroelectric specimens (PZT-5) with cracks of different inclined angles, subjected to alternate electric fields. The cracks were found to deviate from their original plane for all inclined angles. The dominant factor of electric fatigue was found to be the ratio of the applied electric field to the coercive field.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Ultrasonics and Acoustic Wave Propagation · Electromagnetic Effects on Materials · Fatigue and fracture mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (10)
Show source-provided references
1. Cao · J. Am. Ceram. Soc. · 1994 · 77 · 178310.1111/j.1151-2916.1994.tb07051.x ↗
2. Weitzing · J. Eur. Ceram. Soc. · 1999 · 19 · 133310.1016/S0955-2219(98)00429-4 ↗
3. Tan · Scri. Mater. · 2000 · 43 · 92510.1016/S1359-6462(00)00514-5 ↗
4. Li · J. Mater. Sci.-Mater. Electron. · 2002 · 13 · 22510.1023/A:1014832001515 ↗
5. Makino · Jpn. J. Appl. Phys. · 1998 · 37 · 530110.1143/JJAP.37.5301 ↗
6. Shang · Mater. Sci. Eng. A––Struct. A · 2001 · 301 · 13110.1016/S0921-5093(00)01812-8 ↗
7. Lynch · J. Intell. Mater. Syst. Struct. · 1995 · 6 · 19110.1177/1045389X9500600206 ↗
8. Osborn · Phys. Rev. · 1945 · 67 · 35110.1103/PhysRev.67.351 ↗
9. Wacker-Chemie GmbH, Munchen (Germany) on the web: http://www.wacker.com
10. Soh · Int. J. Solids Struct. · 2001 · 38 · 833110.1016/S0020-7683(01)00080-4 ↗