Non-contact mapping of heavy metal contamination for silicon IC fabrication
Source abstract
Abstract
The authors present the principles and application examples of a recently refined, computerised, surface photovoltage (SPV) method. This new method is capable of wafer-scale, non-contact mapping of metal contaminants in the bulk and on the surface with sensitivities as high at 1010 atoms cm-3. They demonstrate the unique ability of SPV to measure product wafers with finished integrated circuits.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Electron and X-Ray Spectroscopy Techniques · Industrial Vision Systems and Defect Detection · Silicon and Solar Cell Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (11)
Show source-provided references
1. Jastrzebski L · 1990 · 614
2. Ohsawa A · 1990 · 601
3. Zoth G · 1990 · 24
4. Ross B · 1980 · 14
5. Goodman A M · J. Appl. Phys. · 1961 · 32 · 255010.1063/1.1728351 ↗
6. ASTM STP F391-87 · 1990
7. Lagowski J · Semicond. Sci. Technol. · 1992 · 7 · A21110.1088/0268-1242/7/1A/041 ↗
8. Moss T S · J. Electron. Control · 1955 · 1 · 12610.1080/00207215508961396 ↗
9. Johnson E O · J. Appl. Phys. · 1957 · 28 · 134910.1063/1.1722650 ↗
10. This range corresponds to the most reliable silicon absorption coefficient data; see Saritas M · J. Appl. Phys. · 1988 · 63 · 456110.1063/1.340155 ↗
11. Note that HF is the strongest Cu contaminant of the most common components of wet cleaning; see Nikkei Microdevices May · 1990 · 54