SIZE MEASUREMENT OF RAW SILK DURING REELING BY USING A PHOTO-ELECTRIC TECHNIQUE
Source abstract
Abstract
The size of raw silk during the reeling process was measured with the detecting device built as trial by using a photo-electric technique.By basic examing of size measurement of raw silk during the reeling process, the following results were obtained:1) Relationship between the size and the output voltage was essentially straight line.2) The detector could be measured slight size change of a cocoon filament continuously.3) The size changes due to dropping end or feeding end of a cocoon filament can be detected by the proposed detector.4) The oscillogram of measured size signal waveform and its time series which was calculated by means of weighing method show similar tendency.5) The reappearance of size measurement by the proposed detector was observed.