High‐Resolution SPECT Imaging of Stimuli‐Responsive Soft Microrobots
Source abstract
Abstract
Abstract Untethered small‐scale robots have great potential for biomedical applications. However, critical barriers to effective translation of these miniaturized machines into clinical practice exist. High resolution tracking and imaging in vivo is one of the barriers that limit the use of micro‐ and nanorobots in clinical applications. Here, the inclusion of radioactive compounds in soft thermoresponsive magnetic microrobots is investigated to enable their single‐photon emission computed tomography imaging. Four microrobotic platforms differing in hydrogel structure and four 99mTc[Tc]‐based radioactive compounds are investigated in order to achieve optimal contrast agent retention and optimal imaging. Single microrobot imaging of structures as low as 100 µm in diameter, as well as tracking of shape switching from tubular to planar configurations by inclusion of 99mTc[Tc] colloid in the hydrogel structure, is reported.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Micro and Nano Robotics · Soft Robotics and Applications · Characterization and Applications of Magnetic Nanoparticles
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Robotics and Intelligent Systems ETH Zurich Zurich CH‐8092 Switzerland
The BioRobotics Institute Scuola Superiore Sant'Anna Pisa 50126 Italy
Center for Radiopharmaceutical Sciences Paul Scherrer Institut Villigen CH‐5232 Switzerland
Department of Chemistry and Applied Biosciences ETH Zurich 8093 Zurich Switzerland
Funding
European Research Council
References (35)
Show source-provided references
1. 10.1002/smll.20180072210.1002/smll.201800722 ↗
2. 10.1146/annurev-control-060117-10494710.1146/annurev-control-060117-104947 ↗
3. 10.1002/adma.20170506110.1002/adma.201705061 ↗
4. 10.1126/scirobotics.aam643110.1126/scirobotics.aam6431 ↗
5. 10.1073/pnas.171603411410.1073/pnas.1716034114 ↗
6. 10.1021/am502729y10.1021/am502729y ↗
7. 10.1109/TMECH.2018.287661710.1109/TMECH.2018.2876617 ↗
8. 10.1016/j.addr.2018.09.00510.1016/j.addr.2018.09.005 ↗
9. 10.1002/adfm.20170610010.1002/adfm.201706100 ↗
10. 10.1007/s10544-015-9962-910.1007/s10544-015-9962-9 ↗
11. 10.1002/adfm.20170592010.1002/adfm.201705920 ↗
12. 10.1038/s41467-017-00309-w10.1038/s41467-017-00309-w ↗
13. 10.1126/scirobotics.aat882910.1126/scirobotics.aat8829 ↗
14. 10.1002/adfm.20180410710.1002/adfm.201804107 ↗
15. 10.1021/acsnano.8b0599710.1021/acsnano.8b05997 ↗
16. 10.1002/advs.20180080710.1002/advs.201800807 ↗
17. 10.1038/545406a10.1038/545406a ↗
18. 10.21037/qims.2018.06.0710.21037/qims.2018.06.07 ↗
19. 10.1002/admt.20180057510.1002/admt.201800575 ↗
20. 10.1002/adma.20140444410.1002/adma.201404444 ↗
21. 10.1021/acsnano.7b0722010.1021/acsnano.7b07220 ↗
22. Cha K. · 2010
23. Khalil I. S. · IEEE Int. Conf. Rob. Autom. · 2014 · 8 · 3807
24. 10.1007/s00270-013-0770-410.1007/s00270-013-0770-4 ↗
25. 10.1126/scirobotics.aaq115510.1126/scirobotics.aaq1155 ↗
26. 10.1002/adma.20050161210.1002/adma.200501612 ↗
27. 10.1021/acs.langmuir.8b0076510.1021/acs.langmuir.8b00765 ↗
28. 10.1038/s41578-018-0016-910.1038/s41578-018-0016-9 ↗
29. 10.1021/la804271d10.1021/la804271d ↗
30. 10.1038/ncomms1226310.1038/ncomms12263 ↗
31. 10.1002/adma.20130409810.1002/adma.201304098 ↗
32. 10.1002/ange.20131104710.1002/ange.201311047 ↗
33. F.D.A. Radiation emitting products https://www.fda.gov/radiation‐emitting‐products/medical‐x‐ray‐imaging/what‐are‐radiation‐risks‐ct (accessed: June2019).
34. 10.1186/2191-219X-4-1410.1186/2191-219X-4-14 ↗
35. Egli A. · J. Nucl. Med. · 1999 · 40 · 1913