Semi-active control of nonlinear smart base-isolated structures using MR damper: sensitivity and reliability analyses
Source abstract
Abstract
Abstract Semi-active control of base-isolated structures using magneto-rheological (MR) dampers is well studied in recent years. However, there is a study gap for sensitivity and reliability analyses assessment of the structure in the literature. Besides, the reliability analysis of the structures based on the importance of the building from a user perspective categorized into three groups including very high, high, and medium is an interesting topic that is considered in this study. Extension of the study for the case of uncontrolled base-isolated structures and controlled ones in both passive-off and passive-on modes of the MR dampers and tuning the command voltage of the MR dampers by a multi-objective modified clipped optimal (MOMCO) controller are also addressed in this paper in different seismic hazard regions with different peak ground accelerations. The Monte Carlo simulation-based Sobol’s indices and importance sampling (IS) method are applied for the sensitivity and reliability analyses. Studies are conducted on an eight-story nonlinear base-isolated structure. The sensitivity analyses show the main seismic responses are more influenced by the changing uncertainties of the stochastic ground acceleration; the mass, and stiffness of the structural model; and the yield force of the isolation system. MR dampers can significantly reduce the failure probabilities of the structures in different seismic hazard regions. By increasing seismic hazard, an increment is observed in failure probability. Enhancing the importance of the building from medium to very-high status leads to an increase in the failure probabilities of the structure in all cases. However, the performance of three control cases in reducing the failure probabilities of the structure is often increased. The MOMCO controller and passive-on mode represent fewer failure probabilities than the uncontrolled and passive-off mode in different seismic hazard regions and groups. However, the MOMCO gives the best performance in the reduction of failure probabilities.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Seismic Performance and Analysis · Vibration Control and Rheological Fluids · Structural Engineering and Vibration Analysis
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Assessment of buckling-restrained braced frame reliability using an experimental limit-state model and stochastic dynamic analysis10.1007/s11803-009-9013-8 ↗
2. Reliability based optimum design of tuned mass damper in seismic vibration control of structures with bounded uncertain parameters10.1016/j.probengmech.2010.07.007 ↗
3. Elias · 2021 · 613
4. Unconditional reliability-based design of tuned liquid column dampers under stochastic earthquake load considering system parameters uncertainties10.1080/13632461003611103 ↗
5. Stochastic dynamic response and reliability assessment of controlled structures with fractional derivative model of viscoelastic dampers10.1016/j.ymssp.2015.11.016 ↗
6. Effect of the damper property variability on the seismic reliability of linear systems equipped with viscous dampers10.1007/s10518-017-0169-8 ↗
7. Reliability of U‐shaped steel dampers used in base‐isolated structures subjected to biaxial excitation10.1002/eqe.2806 ↗
8. Reliability analysis of semiactive magnetorheological dampers subjected to harmonic excitations10.1155/2013/643927 ↗
9. Reliability assessment and seismic control of irregular structures by magnetorheological fluid dampers10.1177/1045389X20977913 ↗
10. Reliability and reliability-based sensitivity analysis of self-centering buckling restrained braces using meta-models10.1177/1045389X211026382 ↗
11. A proposed approach to mitigate the torsional amplifications of asymmetric base-isolated buildings during earthquakes10.1007/s12205-015-0325-0 ↗
12. Optimal design of pure-friction isolators with and without restoring device: a multi-objective cuckoo search-based approach for seismic-excited structures10.1016/j.istruc.2020.03.041 ↗
13. Performance limits of seismically isolated buildings under near-field earthquakes10.1016/j.engstruct.2016.02.043 ↗
14. Online tuning of fractional order fuzzy PID controller in smart seismic isolated structures10.1007/s10518-017-0294-4 ↗
15. Nonlinear response of RC framed buildings with isolation and supplemental damping at the base subjected to near-fault earthquakes10.1080/13632460802632302 ↗
16. Active and semi-active control of structures–theory and applications: a review of recent advances10.1177/1045389X12445029 ↗
17. Adaptive fractional order fuzzy proportional–integral–derivative control of smart base-isolated structures equipped with magnetorheological dampers10.1177/1045389X17721046 ↗
18. Optimal control: basis for performance comparison of passive and semiactive isolation systems10.1061/(ASCE)0733-9399(2006)132:7(705) ↗
19. Design of a decoupled PID controller via MOCS for seismic control of smart structures10.12989/eas.2016.10.5.1067 ↗
20. Semiactive conceptual fuzzy control of magnetorheological dampers in an irregular base‐isolated benchmark building optimized by multi‐objective genetic algorithm10.1002/stc.2302 ↗
21. A new framework of multi-objective BELBIC for seismic control of smart base-isolated structures equipped with MR dampers
22. Seismic protection of the horizontally curved bridge with semi-active variable stiffness damper and isolation system10.1177/1369433216634477 ↗
23. Curved surface sliders with friction damping, linear viscous damping, bow tie friction damping, and semiactively controlled properties10.1002/stc.2257 ↗
24. Effect of stiffness variability on the response of isolated structures10.1002/(SICI)1096-9845(200001)29:1<19::AID-EQE893>3.0.CO;2-9 ↗
25. Sensitivity of seismically isolated structures10.1002/eqe.879 ↗
26. eismic reliability of base-isolated structures with friction pendulum bearings10.1016/j.engstruct.2015.03.053 ↗
27. Seismic reliability-based design of inelastic base-isolated structures with lead-rubber bearing systems10.1016/j.soildyn.2018.09.033 ↗
28. Seismic reliability assessment of base-isolated structures using artificial neural network: operation failure of sensitive equipment
29. Reliability-based design of steel moment frame structures isolated by lead-rubber bearing systems10.1016/j.istruc.2019.06.020 ↗
30. Reliability-based design optimization of adaptive sliding base isolation system for improving seismic performance of structures10.1016/j.ress.2020.107167 ↗
31. Sensitivity analysis on optimal PID controller for nonlinear smart base-isolated structures10.1142/S0219455419500809 ↗
32. Reliability of semi-active seismic isolation under near-fault earthquakes10.1016/j.ymssp.2018.04.045 ↗
33. Experimental verification of multiinput seismic control strategies for smart dampers10.1061/(ASCE)0733-9399(2001)127:11(1152) ↗
34. Modeling of a magneto-rheological damper: an improved multi-state-dependent parameter estimation approach10.1177/1045389X19835938 ↗
35. Cuckoo search via Lévy flights
36. Cuckoo optimization algorithm10.1016/j.asoc.2011.05.008 ↗
37. Cuckoo search: recent advances and applications10.1007/s00521-013-1367-1 ↗
38. Design optimization of truss structures using cuckoo search algorithm10.1002/tal.1033 ↗
39. Multiobjective cuckoo search for design optimization10.1016/j.cor.2011.09.026 ↗
40. Modeling and control of magnetorheological dampers for seismic response reduction10.1088/0964-1726/5/5/006 ↗
41. Sensitivity estimates for nonlinear mathematical models
42. Asymptotic normality and efficiency of two Sobol index estimators10.1051/ps/2013040 ↗
43. Nowak · 2012
44. The Monte Carlo method10.1080/01621459.1949.10483310 ↗
45. Importance sampling in structural systems10.1016/0167-4730(89)90003-9 ↗
46. Importance sampling: a review10.1002/wics.56 ↗
47. System identification through nonstationary data using time–frequency blind source separation10.1016/j.jsv.2016.02.011 ↗
48. Hurtado Gómez · 2010
49. Optimum lead–rubber isolation bearings for near-fault motions10.1016/j.engstruct.2006.12.010 ↗
50. Protecting vibration-sensitive contents: an investigation of floor accelerations in seismically isolated buildings10.1007/s10518-010-9236-0 ↗
51. Seismic structural and non-structural performance evaluation of highly damped self-centering and conventional systems10.1016/j.engstruct.2011.04.001 ↗