Hysteretic behaviour and structural control performance of a piezoelectric friction damper
Source abstract
Abstract
Abstract This study proposes a novel piezoelectric friction damper (PFD). Experiments and numerical simulations are carried out to investigate the mechanical model of the PFD, and the effects of loading speed, displacement amplitude, voltage, friction plate material, piezoelectric stack actuator dimensions, and spring parameters on the hysteretic characteristics of the PFD. Results show that the PFD attains a stable mechanical performance within the design loading speed and displacement amplitude. The piezoelectric stack actuator functioning as a friction control device, can increase friction by 54% at 120 V. In damper design, an appropriate increase of the constraint stiffness of the damper and a piezoelectric stack actuator with the same stiffness as the damper constraint can achieve greater output force, and the preload of the spring should be greater than the friction to prevent residual displacement. The PFD has better seismic performance for large-span cable dome structures than the traditional friction damper. The vertical peak displacement and acceleration reduction ratio reached 45.1% and 67.7% with PFDs, respectively. The PFD with semi-active control is suitable for large-span spatial structures.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Vibration Control and Rheological Fluids · Seismic Performance and Analysis · Geophysics and Sensor Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Ultimate bearing capacity of the welded hollow spherical joints in spatial reticulated structures10.1016/j.engstruct.2003.08.012 ↗
2. Energy dissipation systems for seismic applications: current practice and recent developments10.1061/(ASCE)0733-9445(2008)134:1(3) ↗
3. A state-of-the-art review of the structural control systems10.1177/1077546313478294 ↗
4. State-of-the-art review of the metallic dampers: testing, development and implementation10.1007/s11831-019-09329-9 ↗
5. A state-of-the-art review on passive friction dampers and their applications10.1016/j.engstruct.2021.112022 ↗
6. Design strategies of the viscous dampers for seismic protection of the building structures: a review10.1016/j.soildyn.2018.12.024 ↗
7. State-of-the-art developments of bypass Magnetorheological (MR) dampers: a review10.1007/s13367-021-0018-9 ↗
8. Hysteretic behavior of a shape memory alloy-friction damper and seismic performance assessment of the cable supported structures and reticulated shells10.1088/1361-665X/abaac1 ↗
9. Three-dimensional vibration control analyses of the long-span space pipe truss structure10.13197/j.eeev.2019.05.52.hanqh.005 ↗
10. Passive vibration suppression of the large space truss structures by viscous damping10.1504/IJSPACESE.2020.110364 ↗
11. Sliding mode control for space grid structure with magnetorheological dampers10.23919/chicc.2017.8027942 ↗
12. Study on the space frame structures incorporated with magnetorheological dampers10.12989/sss.2017.19.3.279 ↗
13. Friction joints for seismic control of the large panel structures10.15554/pcij.11011980.38.61 ↗
14. Response of the friction damped braced frames10.1061/JSDEAG.0005968 ↗
15. Slotted bolted connections in aseismic design for concentrically braced connections10.1193/1.1585528 ↗
16. The use of the energy dissipating restraint for seismic hazard mitigation10.1193/1.1585725 ↗
17. Performance of the steel frames with a new friction damper device under earthquake excitation10.1016/S0141-0296(01)00102-X ↗
18. Numerical and experimental study of the hysteretic behavior of the cylindrical friction dampers10.1016/j.engstruct.2011.07.029 ↗
19. Development of a multiaction hybrid damper for passive energy dissipation10.1155/2018/5630746 ↗
20. Fault behavior and characteristic earthquakes: examples from the Wasatch and San Andreas fault zones10.1029/JB089iB07p05681 ↗
21. Seismicity in source regions of the large interplate earthquakes around Japan and the characteristic earthquake model10.1186/BF03352955 ↗
22. Simplified method for optimal design of the friction damper slip loads by considering near-field and far-field ground motions10.1080/13632469.2019.1605316 ↗
23. Seismic reduction tests of a model structure with piezoelectric friction damper10.13465/j.cnki.jvs.2011.06.055 ↗
24. Semi-active optimization control of the space truss model with piezoelectric friction damper10.14006/j.jzjgxb.2014.08.029 ↗
25. A semi-active piezoelectric friction damper10.1002/eqe.2469 ↗
26. Vibration control tests of a model structure installed with piezoelectric friction damper with reset function10.13465/j.cnki.jvs.2015.14.009 ↗
27. Experimental and numerical study of a new adjustable frictional damper10.1016/j.jcsr.2015.05.019 ↗
28. Steel tubular friction damper and vibration reduction effects10.1016/j.jcsr.2020.106019 ↗
29. A comprehensive review on piezoelectric energy harvesting technology: materials, mechanisms, and applications10.1063/1.5074184 ↗
30. Determination of normal force for optimal energy dissipation of harmonic disturbance in a semi-active device10.1016/j.jsv.2007.09.021 ↗
31. Non-linear control of a piezoelectric actuator system for a phase shift interferometer10.1364/JOT.86.000296 ↗
32. JGJ297-2013 · 2013
33. GB50011-2010 · 2010
34. A continuous dynamic constitutive model for normal- and high-strength structural steels10.1016/j.jcsr.2022.107254 ↗
35. Mechanical properties of the brass under impact and perforation tests for a wide range of the temperatures: experimental and numerical approach10.3390/ma13245821 ↗
36. Prestress design of ellipsoid hybrid form and parameter analysis of design factors10.1061/(ASCE)AS.1943-5525.0000964 ↗
37. Study on semi-active particle damping technology for offshore platform truss structure10.21595/jve.2016.17365 ↗