Voltage-controlled IPMC actuators for accommodating intra-ocular lens systems
Source abstract
Abstract
Abstract An ion polymer–metal composite (IPMC) actuator has unique performance characteristics that were applied in this study for use within the eye. Cataracts are a common eye disease causing clouding of the lens. To treat cataracts, surgeons replace clouded lenses with intraocular lenses (IOLs). However, patients who receive this treatment must still wear reading glasses for tasks requiring close-up vision. We suggest a new voltage-controlled accommodating IOL consisting of an IPMC actuator to change the lens’ focus. We examined the relationship between the displacement performance of an IPMC actuator and the accommodating range of the IOL using in vitro experiments. We show that this system has an accommodating range of approximately 1.15 D under an applied voltage of ±1.2 V. By Lagrange interpolation, we estimate that with an IPMC actuator displacement of 0.14 mm, we can achieve a refractive power of 4 D, which is equivalent to the accommodating range of a 40 year old person.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Dielectric materials and actuators · Ferroelectric and Piezoelectric Materials · Vibration Control and Rheological Fluids
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Inorganic Functional Material Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Osaka,
University of Tsukuba
Osaka University Graduate School of Medicine
Funding
Japan Society for the Promotion of Science
References (11)
Show source-provided references
1. Use of DuraHeart® support for more than 1 year as the first successful bridge to heart transplantation in Japan10.1007/s10047-010-0524-x ↗
2. Development of design methods for a centrifugal blood pump with a fluid dynamic approach: results in hemolysis tests10.1046/j.1525-1594.1999.06417.x ↗
3. Polymer actuator driven by ion current at low voltage, applied to catheter system
4. A bio-inspired multi degree of freedom actuator based on a novel cylindrical ionic polymer–metal composite material10.1016/j.robot.2012.07.015 ↗
5. Solid polymer electrolyte membrane flow sensor for tracheal tube10.1117/12.658928 ↗
6. Voltage-controlled accommodating IOL system using an ion polymer metal composite actuator10.1364/OE.24.023280 ↗
7. Visual outcomes and accommodative response of the lumina accommodative intraocular lens10.1016/j.ajo.2016.01.006 ↗
8. Visual and accommodative outcomes 1 year after implantation of an accommodating intraocular lens based on a new concept10.1016/j.jcrs.2009.04.043 ↗
9. Design strategies for new accommodating IOLs
10. Design and validity of a miniaturized open-field aberrometer10.1016/j.jcrs.2012.08.052 ↗
11. Force control of integrated ionic polymer–metal composite actuators with stochastic ON/OFF controller10.1299/jsmemecj.2016.J1110202 ↗