journal article·2022-12-01

A frequency-dependent variable-damping control based variable-orifice damper for smart base-isolation system

Zhong-Xian Li, Dongbin Wen, Yundong Shi, Xin Wei

Smart Materials and Structures· Volume 31· Issue 12
Publisher page

Abstract

Abstract Damping devices are commonly used in the isolation layer of base-isolated structures to provide additional damping to control the structural responses. Normally, large damping for the isolation layer is useful to minimize the resonance effect under low-frequency ground motions, and small damping is preferred to reduce the structural responses under high-frequency ground motions. Traditional passive dampers are widely adopted in engineering practice. Due to the fixed damping characteristic, however, the performance of base-isolated structures with passive dampers cannot stay optimal under ground motions with different frequency characteristics. To realize an optimal control of base-isolated structures, semi-active control has been increasingly valued for its efficiency and intelligence to adjust the damping characteristics based on feedback information from the structure and ground motion. However, a large number of sensors and hardware components are required for semi-active control, which makes the system complex and costly. In this paper, a variable-orifice damper (VOD) for smart base-isolation system is proposed. The VOD can adaptably adjust its damping according to the frequency of the ground motion without additional power or sensors. Theoretical analysis and sinusoidal excitation tests were carried out to investigate the behavior of VOD. A series of numerical simulations of a base‐isolated structure equipped with the proposed VOD and subjected to ground motions are also conducted. A semi-active control with ON-OFF strategy, and two passive controls (passive-on and passive-off) are conducted for comparison. The simulation results show that the VOD can result in an optimal control under ground motions with different frequency characteristics.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vibration Control and Rheological Fluids · Seismic Performance and Analysis · Structural Health Monitoring Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. The role of damping in seismic isolation10.1002/(SICI)1096-9845(199901)28:1<3::AID-EQE801>3.0.CO ↗
2. Base isolation for near‐fault motions10.1002/eqe.31 ↗
3. Rigidity–plasticity–viscosity: can electrorheological dampers protect base-isolated structures from near-source ground motions10.1002/(SICI)1096-9845(199705)26:5<571::AID-EQE658>3.0.CO;2-6 ↗
4. Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations10.1016/j.engstruct.2007.07.020 ↗
5. Resonant behavior of base-isolated high-rise buildings under long-period ground motions10.1002/tal.298 ↗
6. Seismic performance of seismic-isolated building for long-period ground motion and limited performance of seismic isolator
7. Semi-active control of isolated and damaged structures using online damage detection10.1088/0964-1726/24/10/105002 ↗
8. Passive response control systems for seismic response reduction: a state-of-the-art review10.1142/S0219455409002965 ↗
9. State of the art of structural control10.1061/(ASCE)0733-9445(2003)129:7(845) ↗
10. Nonlinear model of pseudoelastic shape memory alloy damper considering residual martensite strain effect10.1155/2012/261896 ↗
11. Second-mode tuned mass dampers in base-isolated structures for reduction of floor acceleration10.1002/eqe.3097 ↗
12. Effectiveness of passive response control devices in buildings under earthquake and wind during design life10.1080/15732479.2018.1547768 ↗
13. Structural control: past, present, and future10.1061/(ASCE)0733-9399(1997)123:9(897) ↗
14. Variable dampers for earthquake protection of benchmark highway bridges10.1088/0964-1726/18/11/115011 ↗
15. Seismic testing of a building structure with a semi‐active fluid damper control system10.1002/(SICI)1096-9845(199707)26:7<759::AID-EQE675>3.0.CO;2-E ↗
16. Semiactive control of the 20-story benchmark building with piezoelectric friction dampers10.1061/(ASCE)0733-9399(2004)130:4(393) ↗
17. Sliding mode fault detection and fault-tolerant control of smart dampers in semi-active control of building structures10.1088/0964-1726/24/12/125030 ↗
18. A spectrum for estimating the maximum control force for passive-base-isolated buildings with LQR control10.1016/j.engstruct.2019.109600 ↗
19. An adaptive‐passive retuning device for a pendulum tuned mass damper considering mass uncertainty and optimum frequency10.1002/stc.2377 ↗
20. Adaptive passive, semiactive, smart tuned mass dampers: identification and control using empirical mode decomposition, Hilbert transform, and short‐term Fourier transform10.1002/stc.349 ↗
21. LQR control with frequency‐dependent scheduled gain for a semi‐active floor isolation system10.1002/eqe.2352 ↗
22. H∞ control in the frequency domain for a semi-active floor isolation system10.1007/s11709-013-0214-x ↗
23. Smart passive system based on magnetorheological damper10.1088/0964-1726/14/4/029 ↗
24. Integration of an omnidirectional self-powering component to an MRE isolator towards a smart passive isolation system10.1016/j.ymssp.2020.106853 ↗
25. A novel velocity self-sensing magnetorheological damper: design, fabricate, and experimental analysis10.1177/1045389X17740961 ↗
26. Oil damper with variable stiffness for the seismic mitigation of cable-stayed bridge in transverse direction10.1016/j.soildyn.2019.105719 ↗
27. Base-isolated building with new-type oil damper for long-period and huge ground motion
28. Study on the development of passive MR damper with displacement-dependent damping characteristics10.1299/jfst.5.86 ↗
29. Velocity & displacement-dependent damper: a novel passive shock absorber inspired by the semi-active control10.1016/j.ymssp.2017.07.008 ↗
30. Non-linear analysis of a quarter-car model with stroke-dependent twin-tube shock absorber10.1016/j.ymssp.2018.06.008 ↗
31. Nonlinear dynamics of a vehicle with a displacement-sensitive mono-tube shock absorber10.1007/s11071-020-05532-7 ↗
32. Theoretical and numerical analysis of regular one-side oscillations in a single pendulum system driven by a magnetic field10.1016/j.ymssp.2020.107229 ↗
33. Seismic analysis and test facilities of deep‐water bridges considering water-structure interaction: a state‐of‐the‐art review10.1002/eer2.8 ↗
34. Horace · 1993
35. Zhang · 2010
36. Kirik · 1986
37. The parametric modeling of local resistance and pressure drop in a rotary ball valve10.1115/1.4037946 ↗
38. Chopra · 2007
39. Collapse assessment of steel moment frames based on E-Defense full-scale shake table collapse tests10.1061/(ASCE)ST.1943-541X.0000608 ↗