journal article·2022-03-01Open access

Motor unit buckling in variable recruitment fluidic artificial muscle bundles: implications and mitigations

Nicholas Mazzoleni, Jeong Yong Kim, Matthew Bryant

Smart Materials and Structures· Volume 31· Issue 3

Abstract

Abstract Fluidic artificial muscles (FAMs) are a popular actuation choice due to their compliant nature and high force-to-weight ratio. Variable recruitment is a bio-inspired actuation strategy in which multiple FAMs are combined into motor units that can be pressurized sequentially according to load demand. In a traditional ‘fixed-end’ variable recruitment FAM bundle, inactive units and activated units that are past free strain will compress and buckle outward, resulting in resistive forces that reduce overall bundle force output, increase spatial envelope, and reduce operational life. This paper investigates the use of inextensible tendons as a mitigation strategy for preventing resistive forces and outward buckling of inactive and submaximally activated motor units in a variable recruitment FAM bundle. A traditional analytical fixed-end variable recruitment FAM bundle model is modified to account for tendons, and the force–strain spaces of the two configurations are compared while keeping the overall bundle length constant. Actuation efficiency for the two configurations is compared for two different cases: one case in which the radii of all FAMs within the bundle are equivalent, and one case in which the bundles are sized to consume the same amount of working fluid volume at maximum contraction. Efficiency benefits can be found for either configuration for different locations within their shared force–strain space, so depending on the loading requirements, one configuration may be more efficient than the other. Additionally, a study is performed to quantify the increase in spatial envelope caused by the outward buckling of inactive or low-pressure motor units. It was found that at full activation of recruitment states 1, 2, and 3, the tendoned configuration has a significantly higher volumetric energy density than the fixed-end configuration, indicating that the tendoned configuration has more actuation potential for a given spatial envelope. Overall, the results show that using a resistive force mitigation strategy such as tendons can completely eliminate resistive forces, increase volumetric energy density, and increase system efficiency for certain loading cases. Thus, there is a compelling case to be made for the use of tendoned FAMs in variable recruitment bundles.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Soft Robotics and Applications · Advanced Materials and Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Modelling of the McKibben artificial muscle: a review10.1177/1045389X11435435 ↗
2. Characterization and analysis of extensile fluidic artificial muscles10.3390/act10020026 ↗
3. The McKibben muscle and its use in actuating robot-arms showing similarities with human arm behaviour10.1108/01439919710192563 ↗
4. Dynamic modeling of Mckibben pneumatic artificial muscles for antagonistic actuation10.1109/ROBOT.2009.5152280 ↗
5. Excitability and inhibitibility of motoneurons of different sizes10.1152/jn.1965.28.3.599 ↗
6. Variable recruitment fluidic artificial muscles: modeling and experiments10.1088/0964-1726/23/7/074009 ↗
7. Improving actuation efficiency through variable recruitment hydraulic McKibben muscles: modeling, orderly recruitment control, and experiments10.1088/1748-3190/11/6/065004 ↗
8. Variable recruitment in bundles of miniature pneumatic artificial muscles10.1088/1748-3190/11/5/056014 ↗
9. Bio-inspired online variable recruitment control of fluidic artificial muscles10.1088/0964-1726/25/12/125016 ↗
10. Design and analysis of electrohydraulic pressure systems for variable recruitment in fluidic artificial muscles10.1088/1361-665X/aadbff ↗
11. Linear dynamometer testing of hydraulic artificial muscles with variable recruitment10.1177/1045389X16682845 ↗
12. Online variable recruitment for pneumatic artificial muscles with springs
13. Variable recruitment testing of pneumatic artificial muscles for robotic manipulators10.1109/TMECH.2014.2341660 ↗
14. Investigation of resistive forces in variable recruitment fluidic artificial muscle bundles10.1007/978-3-030-47717-2_32 ↗
15. Modeling of resistive forces and buckling behavior in variable recruitment fluidic artificial muscle bundles10.3390/act10030042 ↗
16. Accounting for elastic energy storage in McKibben artificial muscle actuators10.1115/1.482478 ↗
17. Hyperelastic analysis of pneumatic artificial muscle with filament-wound sleeve and coated outer layer10.1088/1361-665X/ab300d ↗
18. Experimental characterization and static modeling of McKibben actuators10.1115/1.3158982 ↗
19. Effects of bladder geometry in pneumatic artificial muscles10.1115/1.4033325 ↗
20. Reconsidering the McKibben muscle: energetics, operating fluid, and bladder material10.1177/1045389X14549872 ↗
21. Modeling and control of McKibben artificial muscle robot actuators10.1109/37.833638 ↗
22. Modeling of braided pneumatic actuators for robotic control10.1109/IROS.2001.976361 ↗