journal article·2018-03-27

Nanopore Opening at Flat and Nanotip Conical Electrodes during Vesicle Impact Electrochemical Cytometry

Xianchan Li, Lin Ren, Johan Dunevall, Daixin Ye, Henry S. White, Martin A. Edwards, Andrew G. Ewing

ACS Nano· Volume 12· Issue 3
Publisher page

Abstract

The oxidation of catecholamine at a microelectrode, following its release from individual vesicles, allows interrogation of the content of single nanometer vesicles with vesicle impact electrochemical cytometry (VIEC). Previous to this development, there were no methods available to quantify the chemical load of single vesicles. However, accurate quantification of the content is hampered by uncertainty in the proportion of substituent molecules reaching the electrode surface (collection efficiency). In this work, we use quantitative modeling to calculate this collection efficiency. For all vesicles except those at the very edge of the electrode, modeling shows that ∼100% oxidation efficiency is achieved when employing a 33 μm diameter disk microelectrode for VIEC, independent of the location of the vesicle release pore. We use this to experimentally determine a precise distribution of catecholamine in individual vesicles extracted from PC12 cells. In contrast, we calculate that when a nanotip conical electrode (∼4 μm length, ∼1.5 μm diameter at the base) is employed, as in intracellular VIEC (IVIEC), the current-time response depends strongly on the position of the catecholamine-releasing pore in the vesicle membrane. When vesicle release occurs with the pore opening occurring far from the electrode, lower currents and partial oxidation (∼75%) of the catecholamine are predicted, as compared to higher currents and ∼100% oxidation, when the pore is close to/at the electrode surface. As close agreement is observed between the experimentally measured vesicular content in intracellular and extracted vesicles from the same cell line using nanotip and disk electrodes, respectively, we conclude that pores open at the electrode surface. Not only does this suggest that electroporation of the vesicle membrane is the primary driving force for catecholamine release from vesicles at polarized electrodes, but it also indicates that IVIEC with nanotip electrodes can directly assess vesicular content without correction.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Microfluidic and Bio-sensing Technologies · Nanopore and Nanochannel Transport Studies · Microfluidic and Capillary Electrophoresis Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Chemistry and Molecular Biology, University of Gothenburg, Kemivägen 10, 41296 Gothenburg, Sweden

Department of Chemical and Chemical Engineering, Chalmers University of Technology, Kemivägen 10, 41296 Gothenburg, Sweden

Department of Chemistry, University of Utah, 315 South 1400 East, Salt Lake City, Utah 84112, United States

Funding

Vetenskapsr?det · Air Force Office of Scientific Research · Knut och Alice Wallenbergs Stiftelse · FP7 Ideas: European Research Council · National Institute of General Medical Sciences

References (44)

Show source-provided references
1. 10.1038/nature0786010.1038/nature07860 ↗
2. 10.1038/nature1132010.1038/nature11320 ↗
3. 10.1126/science.119313410.1126/science.1193134 ↗
4. 10.1126/science.aad299610.1126/science.aad2996 ↗
5. 10.1002/anie.20150674310.1002/anie.201506743 ↗
6. 10.1002/anie.20150380110.1002/anie.201503801 ↗
7. 10.1002/anie.20140474410.1002/anie.201404744 ↗
8. 10.1016/j.electacta.2014.02.05910.1016/j.electacta.2014.02.059 ↗
9. 10.1039/C4AN01932F10.1039/C4AN01932F ↗
10. 10.1073/pnas.88.23.1075410.1073/pnas.88.23.10754 ↗
11. Zhou R. · J. Neurosci. · 1994 · 14 · 240210.1523/JNEUROSCI.14-04-02402.1994 ↗
12. 10.1111/j.1471-4159.2005.03087.x10.1111/j.1471-4159.2005.03087.x ↗
13. 10.1074/jbc.272.13.832510.1074/jbc.272.13.8325 ↗
14. 10.1111/j.1471-4159.2005.03526.x10.1111/j.1471-4159.2005.03526.x ↗
15. 10.1016/j.bbamcr.2007.03.01310.1016/j.bbamcr.2007.03.013 ↗
16. Machado J. D. · Mol. Pharmacol. · 2001 · 60 · 51410.1016/S0026-895X(24)12613-2 ↗
17. 10.1111/jnc.1384910.1111/jnc.13849 ↗
18. 10.1113/jphysiol.2002.01863010.1113/jphysiol.2002.018630 ↗
19. 10.1016/S0896-6273(01)00418-410.1016/S0896-6273(01)00418-4 ↗
20. 10.1002/cphc.20090064710.1002/cphc.200900647 ↗
21. 10.1038/srep0090710.1038/srep00907 ↗
22. 10.1017/S003358351600008110.1017/S0033583516000081 ↗
23. 10.1021/ja512972f10.1021/ja512972f ↗
24. 10.1002/anie.20150483910.1002/anie.201504839 ↗
25. 10.1039/C6FD00102E10.1039/C6FD00102E ↗
26. 10.1002/anie.20160297710.1002/anie.201602977 ↗
27. 10.1021/acs.accounts.6b0033110.1021/acs.accounts.6b00331 ↗
28. 10.1002/anie.20170009510.1002/anie.201700095 ↗
29. 10.1021/acsnano.6b0723310.1021/acsnano.6b07233 ↗
30. 10.1038/s41570-017-004810.1038/s41570-017-0048 ↗
31. 10.1002/anie.20170718710.1002/anie.201707187 ↗
32. 10.1021/acschemneuro.6b0035010.1021/acschemneuro.6b00350 ↗
33. 10.1002/anie.20140893410.1002/anie.201408934 ↗
34. 10.1021/acs.langmuir.5b0312310.1021/acs.langmuir.5b03123 ↗
35. 10.1021/ja500713w10.1021/ja500713w ↗
36. 10.1039/C6FD90066F10.1039/C6FD90066F ↗
37. 10.1021/acs.analchem.7b0222610.1021/acs.analchem.7b02226 ↗
38. 10.1021/cn900040e10.1021/cn900040e ↗
39. 10.1002/(SICI)1521-3765(19990702)5:7<2151::AID-CHEM2151>3.0.CO;2-R10.1002/(SICI)1521-3765(19990702)5:7<2151::AID-CHEM2151>3.0.CO;2-R ↗
40. 10.1016/S0006-3495(97)78149-910.1016/S0006-3495(97)78149-9 ↗
41. 10.1021/ac00251a05410.1021/ac00251a054 ↗
42. 10.1073/pnas.81.11.341410.1073/pnas.81.11.3414 ↗
43. Lide D. R · 2005 · 93
44. 10.1038/nmeth78210.1038/nmeth782 ↗