High-Performance Cold Cathode X-ray Tubes Using a Carbon Nanotube Field Electron Emitter
Source abstract
Abstract
A cold cathode X-ray tube was fabricated using a carbon nanotube (CNT) field electron emitter made by a free-standing CNT film which is composed of a highly packed CNT network. A lot of CNT bundles with a sharp tip are vertically aligned at the edge of the thin CNT film with a length of 10 mm and a thickness of 7 μm. The cold cathode X-ray tube using the CNT field emitter presents an extremely high tube current density of 152 A/cm2 (corresponding to tube current of 106.4 mA), the electron beam transmittance of 95.2% and a small focal spot size (FSS) of 0.5 mm. In addition, the cold cathode X-ray tube also shows stable lifetime during 100 000 shots. High emission current density of the cold cathode X-ray tube is mainly attributed to a lot of electron emission sites at an edge of the CNT film. The small FSS is caused by an ensemble of the CNT field electron emitter made by a free-standing thin CNT film and the optimized curve-shape elliptical focusing lens. Based on obtained results, the cold cathode X-ray tube can be widely used for various X-ray applications such as medical diagnosis systems and security check systems in the future.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Carbon Nanotubes in Composites · Advanced Electron Microscopy Techniques and Applications · Diamond and Carbon-based Materials Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electrical Engineering, Korea University, Seoul 02841, Republic of Korea
School of Civil, Environmental and Architectural Engineering, Korea University, Seoul 02841, Republic of Korea
Funding
National Research Foundation of Korea · Korea University
References (62)
Show source-provided references
1. 10.1063/1.136727810.1063/1.1367278 ↗
2. 10.1063/1.149230510.1063/1.1492305 ↗
3. 10.1063/1.192375010.1063/1.1923750 ↗
4. 10.1063/1.219879310.1063/1.2198793 ↗
5. 10.1116/1.218378510.1116/1.2183785 ↗
6. 10.1088/0957-4484/20/32/32570710.1088/0957-4484/20/32/325707 ↗
7. 10.1186/1556-276X-7-25810.1186/1556-276X-7-258 ↗
8. 10.3390/ma511235310.3390/ma5112353 ↗
9. 10.1116/1.476997010.1116/1.4769970 ↗
10. 10.1088/0957-4484/24/8/08520110.1088/0957-4484/24/8/085201 ↗
11. 10.1016/j.carbon.2015.07.04410.1016/j.carbon.2015.07.044 ↗
12. 10.1063/1.493800610.1063/1.4938006 ↗
13. 10.3390/ma1008087810.3390/ma10080878 ↗
14. 10.1088/1361-6528/aac64610.1088/1361-6528/aac646 ↗
15. 10.1063/5.000531910.1063/5.0005319 ↗
16. 10.1088/0031-9155/60/1/8110.1088/0031-9155/60/1/81 ↗
17. 10.1002/wnan.147510.1002/wnan.1475 ↗
18. 10.1109/LED.2018.287372710.1109/LED.2018.2873727 ↗
19. 10.1116/1.500710610.1116/1.5007106 ↗
20. 10.1109/TED.2019.294387010.1109/TED.2019.2943870 ↗
21. 10.1002/mp.1469610.1002/mp.14696 ↗
22. 10.1063/5.006133210.1063/5.0061332 ↗
23. 10.1109/TED.2021.309731510.1109/TED.2021.3097315 ↗
24. Gupta, A. P.; Yeo, S. J.; Jang, J.; Jung, J.; Choi, J.; Lim, J.; Kim, W.; Park, J.; Park, H.; Chae, M. S.; Yeon, Y. H.; Ahn, J. S.; Kim, S. H.; Kim, N.; Ko, B.; Ryu, J. Development of microfocus x-ray source based on CNT emitter for intraoperative specimen radiographic system. Proceedings of SPIE, the international society for optics and photonics, Virtual conference, California, USA, February 15–10; 2021; 115953J.10.1117/12.2582087 ↗
25. Kang, J.T.; Jeong, J.W.; Park, S.; Kim, J.W.; Yun, K. N.; Go, E.; Lee, J.W.; Jeon, H.; Ahn, Y.; Yeon, J.H.; Kim, S.; Song, Y.H. Ultra-short, high-dose rate digital x-ray tube based on carbon nanotube emitters for advanced cone-beam breast computed tomography. Proceedings of SPIE, the international society for optics and photonics, Town and Country Resort & Convention Center, San Diego, California, USA, February 16–21, 2019; 109481I.10.1117/12.2512685 ↗
26. 10.1038/3042010.1038/30420 ↗
27. 10.1103/PhysRevLett.87.21550210.1103/PhysRevLett.87.215502 ↗
28. 10.1126/science.284.5419.150810.1126/science.284.5419.1508 ↗
29. 10.1038/381678a010.1038/381678a0 ↗
30. 10.1126/science.269.5230.155010.1126/science.269.5230.1550 ↗
31. 10.1126/science.270.5239.117910.1126/science.270.5239.1179 ↗
32. 10.1038/3922110.1038/39221 ↗
33. 10.1063/1.12203710.1063/1.122037 ↗
34. 10.1016/S0009-2614(99)01074-X10.1016/S0009-2614(99)01074-X ↗
35. 10.1063/1.12525310.1063/1.125253 ↗
36. 10.1016/S0009-2614(00)00751-X10.1016/S0009-2614(00)00751-X ↗
37. 10.1002/adma.20040012410.1002/adma.200400124 ↗
38. 10.1063/1.223646510.1063/1.2236465 ↗
39. 10.1088/0957-4484/20/31/31520110.1088/0957-4484/20/31/315201 ↗
40. 10.1016/j.carbon.2006.04.00910.1016/j.carbon.2006.04.009 ↗
41. 10.1021/nl072298y10.1021/nl072298y ↗
42. 10.1063/1.295277110.1063/1.2952771 ↗
43. 10.1016/j.carbon.2015.03.04110.1016/j.carbon.2015.03.041 ↗
44. 10.1038/364514a010.1038/364514a0 ↗
45. 10.1126/science.110124310.1126/science.1101243 ↗
46. 10.1126/science.122806110.1126/science.1228061 ↗
47. 10.1063/1.492705210.1063/1.4927052 ↗
48. 10.1088/0957-4484/18/26/26570210.1088/0957-4484/18/26/265702 ↗
49. 10.1016/j.carbon.2016.01.02610.1016/j.carbon.2016.01.026 ↗
50. 10.1063/1.12575810.1063/1.125758 ↗
51. 10.1063/1.12625810.1063/1.126258 ↗
52. 10.1148/radiology.144.2.708929510.1148/radiology.144.2.7089295 ↗
53. 10.1109/LED.2015.240487410.1109/LED.2015.2404874 ↗
54. Canon Electron Tubes & Devices Co., Ltd. Electron Tubes & Devices Product Catalog. 1385, Shimoishigami, Otawara-shi, Tochigi 324–8550, Japan, 2022.
55. Siemens Healthineers. OEM X-ray Components. Henkestr. 127, 91052 Erlangen, Germany, 2018.
56. 10.1088/0031-9155/59/10/239310.1088/0031-9155/59/10/2393 ↗
57. Poliakine, R.; Ilan, N. Dawn of Digital X-ray Sources: Nano-X Imaging Ltd. Proceedings of RSNA, the radiology society of north america, Virtual conference, November 29 to December 5; 2020.
58. 10.1118/1.321352010.1118/1.3213520 ↗
59. 10.1118/1.369466710.1118/1.3694667 ↗
60. 10.1016/j.net.2016.01.01210.1016/j.net.2016.01.012 ↗
61. Iida, K.; Kenmotsu, H.; Yamazaki, J.; Masuya, H. Devices Having an Electron Emitting Structure. US Patent US10,242,836, field March 14, 2013, and issued March 26, 2019.
62. 10.1016/j.mee.2015.12.02110.1016/j.mee.2015.12.021 ↗